scholarly journals SHORT TERM RESULTS OF TRANSCATHETER AORTIC VALVE IMPLANTATION: GLOBAL AND REGIONAL SYSTOLIC LEFT AND RIGHT VENTRICULAR FUNCTION EVALUATED BY ECHOCARDIOGRAPHY EXTENDED WITH TISSUE DOPPLER IMAGING

2010 ◽  
Vol 55 (10) ◽  
pp. A148.E1388
Author(s):  
Lena M. Helin ◽  
éva Tamás ◽  
Farkas Vánky ◽  
Niels Erik Nielsen ◽  
Jan Engvall ◽  
...  
2021 ◽  
Vol 10 (19) ◽  
pp. 4563
Author(s):  
Marisa Avvedimento ◽  
Anna Franzone ◽  
Attilio Leone ◽  
Raffaele Piccolo ◽  
Domenico Simone Castiello ◽  
...  

(1) Aims: We sought to assess the impact of the extent of cardiac damage on survival among real-world patients with severe aortic stenosis (AS) undergoing transcatheter aortic valve implantation (TAVI). (2) Methods: A staging classification was applied to 262 patients from the EffecTAVI Registry at baseline and re-assessed within 30-days after TAVI. The primary endpoint of the study was all-cause mortality at 1-year. Secondary endpoints included cerebrovascular accident, myocardial infarction, permanent pacemaker implantation, endocarditis, and re-hospitalization for all causes. (3) Results: At baseline, 23 (8.7%) patients were in Stage 0/1 (no cardiac damage/left ventricular damage), 106 (40.4%) in Stage 2 (left atrial or mitral valve damage), 59 (22.5%) in Stage 3 (pulmonary vasculature or tricuspid valve damage) and 74 (28.3%) in Stage 4 (right ventricular damage). At 30-days after TAVI, a lower prevalence of advanced stages of cardiac damage than baseline, mainly driven by a significant improvement in left ventricular diastolic parameters and right ventricular function, was reported. At 1-year, a stepwise increase in mortality rates was observed according to staging at baseline: 4.3% in Stage 0/1, 6.6% in Stage 2, 18.6% in Stage 3 and 21.6% in Stage 4 (p = 0.08). No differences were found in secondary endpoints. (4) Conclusions: TAVI has an early beneficial impact on the left ventricular diastolic and right ventricular function. However, the extent of cardiac damage at baseline significantly affects the risk of mortality at 1-year after the procedure.


Author(s):  
Guglielmo Gallone ◽  
Francesco Bruno ◽  
Teresa Trenkwalder ◽  
Fabrizio D’Ascenzo ◽  
Fabian Islas ◽  
...  

AbstractChange in longitudinal left ventricular (LV) systolic function serves as an early marker of the deleterious effect of aortic stenosis (AS) and other cardiac comorbidities on cardiac function. We explored the prognostic value of tissue Doppler imaging (TDI)-derived longitudinal LV systolic function, defined by the peak systolic average of lateral and septal mitral annular velocities (average S’) among symptomatic patients with severe AS undergoing transcatheter aortic valve implantation (TAVI). 297 consecutive patients with severe AS undergoing TAVI at three european centers with available average S’ at preprocedural echocardiography were retrospectively included. The primary endpoint was the Kaplan Meier estimate of all-cause mortality. After a median 18 months (IQR 12–18) follow-up, 36 (12.1%) patients had died. Average S’ was associated with all-cause mortality (per 1 cm/sec decrease: HR 1.29, 95%CI 1.03–1.60, p = 0.025), the cut-off of 6.5 cm/sec being the most accurate. Patients with average S’ < 6.5 cm/sec (55.2%) presented characteristics of more advanced LV remodeling and functional impairment along with higher burden of cardiac comorbidities, and experienced higher all-cause mortality (17.6% vs. 7.5%, p = 0.007), also when adjusted for in-study outcome predictors (adj-HR: 2.69, 95%CI 1.22–5.93, p = 0.014). Results were consistent among patients with preserved ejection fraction, normal-flow AS, high-gradient AS and in those without LV hypertrophy. Longitudinal LV systolic function assessed by average S’ is independently associated with long-term all-cause mortality among TAVI patients. An average S’ below 6.5 cm/sec best defines clinically meaningful reduced longitudinal systolic function and may aid clinical risk stratification in these patients.


Sign in / Sign up

Export Citation Format

Share Document