scholarly journals WHAT DRIVES FOLLOW-UP OF PEDIATRIC BICUSPID AORTIC VALVE: PROVIDER PREFERENCE OR DISEASE CHARACTERISTICS?

2016 ◽  
Vol 67 (13) ◽  
pp. 1003
Author(s):  
Melissa Yamauchi ◽  
Michael Puchalski ◽  
Hsin-Yi Weng ◽  
Nelangi Pinto ◽  
L. LuAnn Minich ◽  
...  
Author(s):  
Alessandro Verzini ◽  
Marta Bargagna ◽  
Guido Ascione ◽  
Alessandra Sala ◽  
Davide Carino ◽  
...  

Background: Bicuspid aortic valve (BAV) is the most common congenital heart defect and it is responsible for an increased risk of developing aortic valve and ascending aorta complications. In case of mild to moderate BAV disease in patients undergoing supracoronary ascending aorta replacement, it is unclear whether a concomitant aortic valve replacement should be performed. Methods: From June 2002 to January 2020, 75 patients with mild-to-moderate BAV regurgitation (± mild-to-moderate stenosis) who underwent isolated supracoronary ascending aorta replacement were retrospectively analyze. Clinical and echocardiographic follow-up was 100% complete (mean: 7.4±3.9 years, max 16.4). Kaplan Meier estimates were employed to analyze long-term survival. Cumulative incidence function for time to re-operation, recurrence of aortic regurgitation (AR)≥3+ and aortic stenosis (AS) greater than moderate, with death as competing risk, were computed. Results: There was no hospital mortality and no cardiac death occurred. Overall survival at 12 years was 97.4±2.5%, 95% CI [83.16-99.63]. At follow-up there were no cases of aortic root surgery whereas 3 patients underwent AV replacement. At 12 years the CIF of reoperation was 2.6±2.5%, 95% CI [0.20-11.53]. At follow up, AR 3+/4+ was present in 1 pt and AS greater than moderate in 3. At 12 years the CIF of AR>2+/4+ was 5.1±4.98% and of AS>moderate 6.9±3.8%. Conclusions: In our study mild to moderate regurgitation of a BAV did not significantly worse at least up to 10 years after isolated supracoronary ascending aorta replacement.


ESC CardioMed ◽  
2018 ◽  
pp. 2861-2863
Author(s):  
Bernard Iung

Aortic diseases encountered in young women are mainly associated with syndromic diseases, which are often heritable, or bicuspid aortic valve. The most frequent syndromic disease is Marfan syndrome. In Marfan syndrome, the risk of aortic dissection is low during pregnancy when the maximum diameter of the ascending aorta is less than 45 mm. Dissection may affect the thoracic ascending or descending aorta. The risk of aortic dissection is low in bicuspid aortic valve when the aortic diameter is less than 50 mm. Beta blockers are recommended throughout pregnancy in Marfan syndrome and are often used in other causes of aortic aneurysms. Close echocardiographic follow-up is needed during pregnancy and after delivery.


ESC CardioMed ◽  
2018 ◽  
pp. 2861-2863
Author(s):  
Bernard Iung

Aortic diseases encountered in young women are mainly associated with syndromic diseases, which are often heritable, or bicuspid aortic valve. The most frequent syndromic disease is Marfan syndrome. In Marfan syndrome, the risk of aortic dissection is low during pregnancy when the maximum diameter of the ascending aorta is less than 45 mm. Dissection may affect the thoracic ascending or descending aorta. The risk of aortic dissection is low in bicuspid aortic valve when the aortic diameter is less than 50 mm. Beta blockers are recommended throughout pregnancy in Marfan syndrome and are often used in other causes of aortic aneurysms. Close echocardiographic follow-up is needed during pregnancy and after delivery.


2019 ◽  
Vol 112 (5) ◽  
pp. 305-313 ◽  
Author(s):  
Ramzi Abi Akar ◽  
Noémie Tence ◽  
Jérome Jouan ◽  
Wassim Borik ◽  
Philippe Menasché ◽  
...  

2020 ◽  
Vol 58 (1) ◽  
pp. 86-93 ◽  
Author(s):  
Erik Beckmann ◽  
Andreas Martens ◽  
Heike Krüger ◽  
Wilhelm Korte ◽  
Tim Kaufeld ◽  
...  

Abstract OBJECTIVES Aortic valve-sparing root replacement is an excellent treatment option for patients with intact tricuspid aortic valves. However, the durability in patients with bicuspid aortic valves is still a matter of debate. The aim of this study was to analyse the short- and long-term outcomes in patients with bicuspid aortic valves. METHODS Between July 1993 and October 2015, a total of 582 patients underwent the David I procedure, 50 of whom had a bicuspid aortic valve. In these patients, the mean age was 46 ± 13 years, and 80% (n = 40) were men. Follow-up was complete for 100% of patients and comprised a total of 552 patient-years with a mean follow-up time of 11 ± 5.2 years. RESULTS In addition to the David procedure, cusp plication was performed in 34% (n = 17) of patients and commissure repair in 8% (n = 4) of patients. There were no in-hospital deaths, and 1 patient (2%) had a perioperative stroke. The 1-, 5-, 10- and 20-year survival rates of patients after discharge were 98%, 94%, 88% and 84%, respectively. The rates for freedom from valve-related reoperation at 1, 5, 10 and 20 years after initial surgery were 98%, 88%, 79% and 74%, respectively. Long-term freedom from reoperation was comparable to that of patients with tricuspid aortic valves (P = 0.2). CONCLUSIONS The David procedure has excellent short-term results in patients with a bicuspid aortic valve. In this study, the long-term durability of reimplanted bicuspid aortic valves was comparable to that of tricuspid valves. However, careful patient selection might have contributed to this, and further studies might be needed to definitely clarify this issue.


2008 ◽  
Vol 34 (3) ◽  
pp. 583-588 ◽  
Author(s):  
Feyzan Özaslan ◽  
Thomas Wittlinger ◽  
Nadejna Monsefi ◽  
Tamimount Bouhmidi ◽  
Sinthu Theres ◽  
...  

2018 ◽  
Vol 49 (1) ◽  
pp. 57-67 ◽  
Author(s):  
Michael J. Rose ◽  
Cynthia K. Rigsby ◽  
Haben Berhane ◽  
Emilie Bollache ◽  
Kelly Jarvis ◽  
...  

2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
A Ielasi ◽  
E Moscarella ◽  
A Mangieri ◽  
D Tchetche ◽  
W Kim ◽  
...  

Abstract Background Transcatheter aortic valve replacement (TAVR) is an established therapy for symptomatic severe aortic stenosis. Bicuspid aortic valves (BAV) were generally excluded from randomized trials due to anatomic features that may challenge TAVR (valve morphology, annulus geometry and size and severe calcifications). Nevertheless real-world registries have shown that a consistent number of BAV has been treated with TAVR. Whether BAV phenotype may affect acute or long-term outcomes following TAVR still remains unclear. Purpose Evaluate the impact of BAV phenotype on procedural and clinical outcomes after TAVR with new generation valves. Methods Patients included in the BEAT (Balloon vs Self-Expandable valve for the treatment of bicuspid Aortic valve sTenosis) registry were classified according to the BAV phenotype. Procedural and clinical outcomes of type 0 (2 cusps, 1 commissure, no raphe) vs type 1 (1 raphe) BAV are here reported. Primary endpoint was post-procedural device success, according to Valve Academic Research Consortium–2 (VARC-2) criteria. Secondary endpoints included procedural complications, rate of permanent pacemaker (PM) implantation and assessment of clinical outcomes at 30-day and 1-year follow-up. Results BAV 0 phenotype was present in 25 (7.1%) cases, and BAV 1 in 218 (61.8%). 3 (0.9%) patients with BAV 2 phenotype and 105 (29.8%) patients in whom BAV phenotype was undeterminable were excluded. Baseline characteristics of the two populations were well balanced. Mean STS score tended to be lower in type 0 vs type 1 BAV (3.35% ±1.8 vs 4.5% ± 3.0, p=0.062). Mean transvalvular gradient, aortic valve area (AVA), and left ventricular ejection fraction didn't differ between groups. According to CT findings moderate-severe aortic valve calcifications were less frequently present in type 0 vs type 1 (52% vs 71.1%, p=0.01). TAVR was performed under conscious sedation in most patients (89.7%), no differences were noted in terms of valve type, valve size, pre and postdilation between groups. There was no significant difference in any peri-procedural complication including pericardial tamponade, second valve implantation, valve embolization, annular rupture, aortic dissection, coronary occlusion, conversion to open surgery, and need of PM between groups however VARC-2 success tended to be lower in type 0 BAV versus type 1 (72% vs 86.7%; p=0.07). A higher rate of mean transvalvular gradient>20 mmHg was observed in the type 0 vs type 1 groups (respectively 24% vs 6%, p=0.007), while no differences were reported in the rate of moderate-severe aortic regurgitation. At 30-day and 1-year follow-up we did not find differences in clinical outcomes. Conclusions Our study confirms the feasibility of TAVR in both type 0 and type 1 BAV, however despite a lower rate of moderate-severe calcifications, a trend toward a lower VARC device success and a higher rate of mean transvalvular gradient >20 mmHg was observed in type 0 vs type 1 BAV. Funding Acknowledgement Type of funding source: None


2008 ◽  
Vol 40 (Supplement) ◽  
pp. S473
Author(s):  
Laura Stefani ◽  
Roberto Mercuri ◽  
Loira Toncelli ◽  
Valentina Di Tante ◽  
Maria Concetta Robertina Vono ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document