scholarly journals A UNIQUE CASE OF HEART FAILURE: IATROGENIC VENTRICULAR SEPTAL DEFECT FOLLOWING TRANSCATHETER AORTIC VALVE REPLACEMENT

2021 ◽  
Vol 77 (18) ◽  
pp. 2411
Author(s):  
Kevin O'Gorman ◽  
Alexandra Smith
2021 ◽  
Vol 5 (5) ◽  
Author(s):  
Klaus-Dieter Hönemann ◽  
Steffen Hofmann ◽  
Frank Ritter ◽  
Gerold Mönnig

Abstract Background A rare, but serious, complication following transcatheter aortic valve replacement (TAVR) is the occurrence of an iatrogenic ventricular septal defect (VSD). Case summary We describe a case of an 80-year-old female who was referred with severe aortic stenosis for TAVR. Following thorough evaluation, the heart team consensus was to proceed with implantation via a transapical approach of an ACURATE neo M 25 mm valve (Boston Scientific, Natick, MA, USA). The valve was deployed harnessing transoesophageal echocardiographic (TOE) guidance under rapid pacing with post-dilation. Directly afterwards a very high VSD close to the aortic annulus was detected. As the patient was haemodynamically stable, the procedure was ended. The next day another TOE revealed a shunt volume (left-to-right ventricle) between 50% and 60%. Because the defect was partly located between the stent struts of the ACURATE valve decision was made to fix this leakage with implantation of a further valve and we chose an EVOLUT Pro 29 mm (Medtronic Inc., Minneapolis, MN, USA). The valve-in-valve was implanted 2–3 mm below the lower edge of the first valve, more towards the left ventricular outflow tract (LVOT) with excellent result: VSD was reduced to a very small residual shunt without any hemodynamic relevance. Discussion We suggest that an iatrogenic VSD located near the annulus may be treated percutaneously in a bail-out situation with implantation of a second valve that should be implanted slightly more into the LVOT to cover the VSD.


Author(s):  
Enrico Ferrari ◽  
Didier Locca ◽  
Denis Berdajs ◽  
Carlo Marcucci ◽  
Fabrizio Gronchi ◽  
...  

During transapical transcatheter aortic valve replacement (TA-TAVR), the apical closure remains a challenge for the surgeon, having the risk for ventricular tear and massive bleeding. Apical closure devices are already under clinical evaluation, but only a few can lead to a full percutaneous TA-TAVR. We describe the successful use of a 9-mm myocardial occluder (ventricular septal defect occluder) that was used to seal the apex after a standard TA-TAVR (using the Sapien XT 23-mm transcatheter valve and the Ascendra + delivery system). The placement of the nonmodified myocardial occluder was performed through the Ascendra + delivery system, with a very small amount of blood loss and an acceptable sealing of the apical tear. This approach is feasible and represents a further step toward true-percutaneous transapical heart valve procedures. Modified apical occluders are under evaluation in animal models.


Author(s):  
Vassili Panagides ◽  
Alberto Alperi ◽  
Jules Mesnier ◽  
Francois Philippon ◽  
Mathieu Bernier ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document