Reduction of local scour at a bridge pier fitted with a collar in a 180 degree flume bend (Case study: oblong pier)

2010 ◽  
Vol 22 (S1) ◽  
pp. 646-650 ◽  
Author(s):  
Alireza Masjedi ◽  
Mahmood Shafaei Bejestan ◽  
Abdolkarim Esfandi
Keyword(s):  
2015 ◽  
Vol 5 (1) ◽  
pp. 9-15
Author(s):  
Shiv Kumar Yadav ◽  
◽  
Shri Ram ◽  

1994 ◽  
pp. 71-79 ◽  
Author(s):  
Shoji Fukuoka ◽  
Kunihiro Tomita ◽  
Tetsuo Hotta ◽  
Tomohiro Miyagawa

2021 ◽  
Vol 248 ◽  
pp. 01015
Author(s):  
Zhejiang Chen ◽  
Liang Liu ◽  
Yonglin Hu ◽  
Nan Ye ◽  
Xiaoli Shen ◽  
...  

Because of the problem of local scour caused by the change of the flow structure caused by the water-resistance of the column bridge pier, the theoretical analysis, and indoor water tank test were used to study the effect of installing a new anti-scouring device in front of the bridge pier on the local scour reduction effect; the influence of the main design parameters such as the height of the protective device, the angle of the protective device and the distance from the protective device to the bridge pier on the local scour of the bridge pier was selected, and the optimal parameter design combination was selected. The test results show that: under the same water flow conditions, the maximum scour depth reduction rate of the measuring point under the protection of the protective device is 48.4% to 74.2% compared with the unprotected scour; the reduction rate of the bridge pier is relative to the relative height of the device and the device equivalent. The angle and the distance between the device and the bridge pier are related, and the shock reduction rate decreases with the increase of the flow intensity. In the test range, the ratio of the device height to the water depth is 2/3, the device angle is 60 °, and the distance from the bridge pier is 3. When the diameter of the pier is doubled, the effect of reducing the impact on the pier is the best.


Water ◽  
2019 ◽  
Vol 11 (7) ◽  
pp. 1515 ◽  
Author(s):  
Shunyi Wang ◽  
Kai Wei ◽  
Zhonghui Shen ◽  
Qiqi Xiang

Local scour of bridge piers is one of the main threats responsible for bridge damage. Adopting scour countermeasures to protect bridge foundations from scour has become an important issue for the design and maintenance of bridges located in erodible sediment beds. This paper focuses on the protective effect of one active countermeasure named an “anti-scour collar” on local scour around the commonly used cylindrical bridge pier. A cylindrical pier model was set up in a current flume. River sand with a median particle size of 0.324 mm was selected and used as the sediment in the basin. A live-bed scour experimental program was carried out to study the protective effect of an anti-scour collar by comparing the local scour at a cylindrical bridge pier model with and without collar. The effects of three design parameters including collar installation height, collar external diameter and collar protection range, on the scour depth and scour development were investigated parametrically. According to the experimental results, it can be concluded that: the application of an anti-scour collar alleviates the local scour at the pier effectively; and the protection effect decreases with an increase in the collar installation height, but increases with an increase in the collar external diameter and the protection range. Design suggestions for improving the scour protective effect of the anti-scour collar are summarized and of great practical guiding significance to the development of anti-scour collars for bridge piers.


Sign in / Sign up

Export Citation Format

Share Document