Monitoring and control of a pulse detonation engine using a diode-laser fuel concentration and temperature sensor

2002 ◽  
Vol 29 (1) ◽  
pp. 161-166 ◽  
Author(s):  
L. Ma ◽  
S.T. Sanders ◽  
J.B. Jeffries ◽  
R.K. Hanson
2003 ◽  
Vol 19 (4) ◽  
pp. 568-572 ◽  
Author(s):  
Daniel W. Mattison ◽  
Christopher M. Brophy ◽  
Scott T. Sanders ◽  
Lin Ma ◽  
Kevin M. Hinckley ◽  
...  

2002 ◽  
Author(s):  
D. Mattison ◽  
S. Sanders ◽  
K. Hinckley ◽  
C. Brophy ◽  
J. Jeffries ◽  
...  

Shock Waves ◽  
2003 ◽  
Vol 12 (6) ◽  
pp. 435-441 ◽  
Author(s):  
S. T. Sanders ◽  
D. W. Mattison ◽  
J. B. Jeffries ◽  
R. K. Hanson

2002 ◽  
Vol 10 (12) ◽  
pp. 505 ◽  
Author(s):  
Scott T. Sanders ◽  
Daniel W. Mattison ◽  
Lin Ma ◽  
Jay B. Jeffries ◽  
Ronald K. Hanson

Author(s):  
Wenlong Zhang ◽  
Chengming Pei ◽  
Jianghong Li ◽  
Wei Fan

A multi-processers monitoring and control system, which use the Lora as wireless communication technology, was designed to meet needs of mobility, safety, fast frequency adjustment, portability, none affect on PDE thrust test and so on. This paper elaborated on scheme of whole system, local high-speed signal acquisition, storage, data export and ignition control method. Experimental results show that the monitoring and control system was able to implement timely and accurately control and data acquisition of detonation tubes, dynamical parameters changing, remote control and eliminate the damage for human beings caused by PDE, with mobile and portable, high integration, convenient operation, reliable performance characteristics.


2020 ◽  
Vol 0 (0) ◽  
Author(s):  
Gui-yang Xu ◽  
Chun-guang Wang ◽  
Yan-fang Zhu ◽  
Hong-yan Li ◽  
Lun-kun Gong ◽  
...  

AbstractThe experiment system of pulse detonation engine is set up to investigate on influence of diameter on detonation acoustic characteristic. The research of detonation acoustic characteristic of pulse detonation engine for four different diameters in different angles is carried out. Results from the test show that as the PDE diameter increasing, there are increases in amplitudes of impact noise in all angles, and the growth rate of amplitude of impact noise in the 90° direction is generally greater than that in the 0° direction. The smaller PDE diameter is, the distance of most obvious directivity at 0° turning to most obvious directivity at 30° is shorter. When the distance is shorter, such as 200 mm, the duration of detonation acoustic is increasing with the increase of PDE diameter, however, when the distance is longer, such as 3000 mm, it is just the opposite. The maximum duration of detonation acoustic is appeared in 3000 mm under 30 mm PDE diameter which reaches to 1.44 ms.


Sign in / Sign up

Export Citation Format

Share Document