scholarly journals 208: Midterm follow-up of patients with paroxysmal and persistent atrial fibrillation after pulmonary vein isolation by cryoballoon ablation

2013 ◽  
Vol 5 (1) ◽  
pp. 68
Author(s):  
Sarah Traullé ◽  
Maciej Kubala ◽  
Jean-Sylvain Hermida
2019 ◽  
Vol 7 (4S) ◽  
pp. 6-14
Author(s):  
T. Y. Chichkova ◽  
S. E. Mamchur ◽  
E. A. Khomenko

Aim. To estimate the clinical success of cryoballoon pulmonary vein isolation (PVI).Methods.230 patients (males: 49.6%, mean age 57 (53; 62) with symptomatic paroxysmal and persistent atrial fibrillation (AF) resistant to antiarrhythmic therapy were included in a single-center prospective study. The patients were randomized into 2 groups to undergo either cryoballoon ablation (n = 122) or radiofrequency (RF) (n = 108) ablation. Both groups were comparable in baseline parameters. The follow-up period was 12 months. Clinical outcomes were estimated with the use of a three-stage scale. The rates of cardiovascular rehospitalizations, direct-current cardioversions and repeated ablations during were estimated within the follow-up. The quality of life (QoL) in the cryoablation group was measured using the AFEQT scale.Results.77% (n = 94) of patients in the cryoballoon ablation group and 71.3% (n = 77) of patients in the RF group (р = 0.71) demonstrated reported the optimal clinical effects. Both groups, cryo ablation and RF ablation, had similar rates of cardiovascular hospitalizations (23.8 vs 28.7%, OR 0.8, 95% CI 0.4–1.4; р = 0.39), direct-current cardioversions (12.3 vs 17.6%, OR 0.7, 95% CI 0.3–1.4; р = 0.26) and repeated ablations (9.8–11.1%, OR 0.9, 95% CI 0.4–2.0; р = 0.75). The patients treated with cryoballoon as opposed to RF ablation had significantly more successful usage of “pill-in-pocket” strategy – 14.8 vs 6.5% (OR 2.5, 95% CI 1.01–6.2; р = 0.04). Significant improvements of the QoL parameters with strong size effect have been found in the cryoablation group, i.e. global score (GS) increased by 8.9±6.9 (95% CI 6.6–10.1; dCohen 1.2; р<0.001), symptoms (S) – by 8.3±7.9 (95% CI 4.2–8.8; dCohen 1.5; р<0.001), daily activities (DA) – by 10.0±6.9 (95% CI = 6.4–10.6; dCohen 0.9; р<0.001), treatment concerns (TC) – by 5.5±6.0 (95% CI 6.3–9.2; dCohen 1.2; р<0.001) and treatment satisfaction (TS) – by 5.5±6.0 (95% CI 5.4–9.8; dCohen 0.9; р<0.001).Conclusion.The both catheter-based technologies had comparable clinical success. Cryoablation was characterized by improvement in all QoL parameters based on the AFEQT score.


2019 ◽  
Vol 40 (Supplement_1) ◽  
Author(s):  
D Musat ◽  
N Milstein ◽  
R Shaw ◽  
A Bhatt ◽  
M Preminger ◽  
...  

Abstract Background Cryoballoon (CB) pulmonary vein isolation (PVI) is increasingly being used in patients (pts) with persistent atrial fibrillation (AF). However, there are limited data about the pattern of atrial fibrillation (AF) recurrence in these pts. Objective To assess, using an implantable loop recorder (ILR), the patterns of AF recurrence following CB PVI in pts with persistent atrial fibrillation. Methods We enrolled consecutive pts with persistent AF ablation undergoing their first CB ablation. Other cavotricuspid isthmus ablation when indicated, no other ablation was performed. A Reveal LINQ ILR (Medtronic) was implanted <3 months following ablation; all pts had a minimum of 1-year follow-up. The recurrence of any atrial arrhythmia was determined and adjudicated; 4 distinct AF patterns were characterized (Figure). Results We studied 64 pts (66±9 years; 50 [78%] male; CHA2DS2-VASc 2.6±1.9) with persistent AF; 52 (81%) pts were on an antiarrhythmic drug (AAD) peri-ablation. During 803±361 days of follow-up, 33 (52%) pts had their 1st AF recurrence 91–365 days post-ablation and another 17 (27%) pts had their 1st AF recurrence >365 days post-ablation. No AF was seen in 14 (31%) pts. Most pts (33 of 50, 66%) with AF recurrence presented with 1 of 3 distinct patterns of paroxysmal AF (Figure), which ranged from 22 min to 124 hours. In 2/3 of these pts, all AF recurrences lasted <24 hours. Only 17 (34%) pts recurred with persistent AF. Conclusion Following single CB PVI, most pts with persistent AF remained free of persistent AF during long-term follow-up. Most pts with recurrent AF have 1 of 3 distinct patterns with episodes commonly last <24 hours. These data suggest that CB PVI ablation may halt AF progression in pts initially presenting with persistent AF.


Circulation ◽  
2015 ◽  
Vol 132 (suppl_3) ◽  
Author(s):  
Emily Guhl ◽  
Donald Siddoway ◽  
Evan Adelstein ◽  
Samir Saba ◽  
Andrew Voigt ◽  
...  

Introduction: Cryoballoon pulmonary vein isolation (PVI) has emerged as an alternative to radiofrequency PVI for the treatment of paroxysmal atrial fibrillation (AF). The optimal ablation strategy for patients with persistent AF is unclear, as data on Cryoballoon PVI alone are limited. Methods: We analyzed a prospective registry of consecutive patients with persistent AF who underwent Cryoballoon PVI at a single center between 2011 and 2014. Patients were assessed for AF recurrence (including any atrial arrhythmia) after a 3 month blanking period at 6 months, 1 year, 2 years, and as needed for symptoms post PVI. Recurrence was based on typical symptoms or ECG/ event monitor evidence of AF. Kaplan-Meier analysis was used to estimate AF-free survival. Results: The 69 patients who underwent Cryoballoon PVI were aged 59 ± 8 years, 86% male, 54% HTN, had a CHADS2-VASC score 1.6 ± 1.2, and had a LA dimension 4.5 ± 0.6 cm. The AF recurrence-free rate at 1-year post-procedure was 59%. Overall, AF-free survival was 50% at the mean follow-up of 607 days. In comparing patients with persistent AF duration <1 year vs. >1 year, there was a trend toward greater AF recurrence-free rates in the <1 year group (66% vs 55%, p=0.09) Conclusions: Cryoballoon PVI appears to be an effective initial strategy in treating persistent AF, with an AF recurrence-free rate of 59% at 1 year.


Sign in / Sign up

Export Citation Format

Share Document