A Calibration Method That Simplifies and Improves Accurate Determination of Peptide Molecular Masses by MALDI-TOF MS

2002 ◽  
Vol 74 (15) ◽  
pp. 3915-3923 ◽  
Author(s):  
Johan Gobom ◽  
Martin Mueller ◽  
Volker Egelhofer ◽  
Dorothea Theiss ◽  
Hans Lehrach ◽  
...  
2009 ◽  
Vol 55 (1) ◽  
pp. 139-149 ◽  
Author(s):  
Klaus Meyer ◽  
Åse Fredriksen ◽  
Per Magne Ueland

Abstract Background: Large cohort studies may provide sufficient power to disentangle the role of polymorphisms related to 1-carbon metabolism and chronic diseases, but they require fast, accurate, high-throughput genotyping techniques. MALDI-TOF mass spectrometry has been adapted to rapid fine mapping using various approaches for allele discrimination. We developed a genotyping method based on MALDI-TOF MS and compared assay performance for formats based on standard and mass-modified terminators. Methods: The assay includes 20 polymorphisms of 14 genes involved in 1-carbon metabolism (BHMT 742G>A, CBS 844ins68 and 699C>T, CTH 1364G>T, DHFR del19, NOS3 –786T>C and 894G>T, FOLR1 1314G>A, MTHFD1 –105T>C and 1958G>A, MTHFR 677C>T and 1298A>C, MTR 2756A>G, MTRR 66A>G and 524C>T, SLC19A1 80G>A, SHMT1 1420C>T, TCN2 67A>G and 776C>G, and TYMS 1494del6). Results: Missing calls were observed for 4.7% of the DNA samples, attributed to failed liquid sample handling. Highly accurate genotyping was obtained by mass-modified as well as standard ddNTPs, with an average error rate of ≤0.1% by analysis of sample duplicates. A semiquantitative approach enabled unambiguous identification of the CBS 844ins68. Cluster plots of the relative allele intensities showed allele-specific bias according to type of minisequencing terminator and revealed a potential structural variation in the BHMT gene. Conclusions: MALDI-TOF MS–based genotyping using either standard or mass-modified terminators allows the accurate determination of single nucleotides as well as structural genetic variants. This was demonstrated with 20 polymorphisms involved in 1-carbon metabolism.


e-Polymers ◽  
2005 ◽  
Vol 5 (1) ◽  
Author(s):  
Slim Salhi ◽  
Martine Tessier ◽  
Jean-Claude Blais ◽  
Rachid El Gharbi ◽  
Alain Fradet

AbstractPoly(ethylene adipate) (PEA) and poly(ethylene dodecanedioate) (PED) with dicarboxy-, dihydroxy-, dimethyl ester- and hydroxy-carboxy end-groups were synthesized and characterized by 13C NMR and MALDI-TOF MS. Size-exclusion chromatography (SEC) fractions of these polyesters were analyzed by MALDI-TOF MS and used as standards to obtain SEC calibration curves leading to the absolute molar masses of the unfractionated polyesters. PEA and PED calibration curves were different from each other, but the same calibration curve was obtained for each type of polyester, irrespective of the nature of end-groups, showing the predominant role of the nature of repeating units on the hydrodynamic volume of oligoesters. The study also shows that the conventional SEC calibration method using polystyrene standards leads to a significant overestimation of polyester average molar masses.


2000 ◽  
Vol 48 (2) ◽  
pp. 150-154 ◽  
Author(s):  
Yoichiro NIHASHI ◽  
Mitsuhiro ISHIDA ◽  
Fumio SAKAMOTO ◽  
Yuichiro NAKADA
Keyword(s):  

2019 ◽  
Vol 411 (22) ◽  
pp. 5833-5843 ◽  
Author(s):  
Missael Antonio Arroyo Negrete ◽  
Kazimierz Wrobel ◽  
Eunice Yanez Barrientos ◽  
Alma Rosa Corrales Escobosa ◽  
Francisco Javier Acevedo Aguilar ◽  
...  

2011 ◽  
Vol 47 (35) ◽  
pp. 9816 ◽  
Author(s):  
Xiao-Shui Li ◽  
Jian-Hong Wu ◽  
Li-Dan Xu ◽  
Qin Zhao ◽  
Yan-Bo Luo ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document