Electrokinetic Transport of Charged Samples through Rectangular Channels with Small Zeta Potentials

2008 ◽  
Vol 80 (12) ◽  
pp. 4723-4730 ◽  
Author(s):  
Debashis Dutta
Author(s):  
Sumita Pennathur ◽  
Juan G. Santiago

We investigate electrokinetic transport in nanometer-scale fluidic channels. Our study includes numerical studies of nanofluidic transport of both charged and uncharged analytes in conditions of finite Debye layer thickness and high zeta potentials. The models are based on continuum mass transport and field theory. We also perform an experimental parametric study using etched nanoscale channels. Experimental results agree with model predictions and show that bulk electrokinetic transport in nanoscale channels depends strongly on the shape and size of the EDL and on the effects of transverse electrophoretic migration.


Kerntechnik ◽  
2017 ◽  
Vol 82 (6) ◽  
pp. 631-636
Author(s):  
Li Zi-chao ◽  
Qi Shi ◽  
Zhou Tao ◽  
Li Bing ◽  
Muhammad Ali Shahzad ◽  
...  

Author(s):  
Bin Sun ◽  
Lei Yang ◽  
Shun Zhu ◽  
Quan Liu ◽  
Cuixia Wang ◽  
...  
Keyword(s):  

2003 ◽  
Vol 67-68 ◽  
pp. 865-871 ◽  
Author(s):  
L. Ceriotti ◽  
K. Weible ◽  
N.F. de Rooij ◽  
E. Verpoorte

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Jian Hou ◽  
Ming Han ◽  
Jinxun Wang

AbstractThis work investigates the effect of the surface charges of oil droplets and carbonate rocks in brine and in surfactant solutions on oil production. The influences of the cations in brine and the surfactant types on the zeta-potentials of both oil droplets and carbonate rock particles are studied. It is found that the addition of anionic and cationic surfactants in brine result in both negative or positive zeta-potentials of rock particles and oil droplets respectively, while the zwitterionic surfactant induces a positive charge on rock particles and a negative charge on oil droplets. Micromodels with a CaCO3 nanocrystal layer coated on the flow channels were used in the oil displacement tests. The results show that when the oil-water interfacial tension (IFT) was at 10−1 mN/m, the injection of an anionic surfactant (SDS-R1) solution achieved 21.0% incremental oil recovery, higher than the 12.6% increment by the injection of a zwitterionic surfactant (SB-A2) solution. When the IFT was lowered to 10−3 mM/m, the injection of anionic/non-ionic surfactant SMAN-l1 solution with higher absolute zeta potential value (ζoil + ζrock) of 34 mV has achieved higher incremental oil recovery (39.4%) than the application of an anionic/cationic surfactant SMAC-l1 solution with a lower absolute zeta-potential value of 22 mV (30.6%). This indicates that the same charge of rocks and oil droplets improves the transportation of charged oil/water emulsion in the porous media. This work reveals that the surface charge in surfactant flooding plays an important role in addition to the oil/water interfacial tension reduction and the rock wettability alteration.


2020 ◽  
Vol 319 ◽  
pp. 02004
Author(s):  
Muhammad Akif Rahman ◽  
Md Badrath Tamam ◽  
Md Sadman Faruque ◽  
A.K.M. Monjur Morshed

In this paper a numerical analysis of three-dimensional laminar flow through rectangular channel heat sinks of different geometric configuration is presented and a comparison of thermal performance among the heat sinks is discussed. Liquid water was used as coolant in the aluminum made heat sink with a glass cover above it. The aspect ratio (section height to width) of rectangular channels of the mini-channel heat sink was 0.33. A heat flux of 20 W/cm2 was continuously applied at the bottom of the channel with different inlet velocity for Reynold’s number ranging from 150 to 1044. Interconnectors and obstacles at different positions and numbers inside the channel were introduced in order to enhance the thermal performance. These modifications cause secondary flow between the parallel channels and the obstacles disrupt the boundary layer formation of the flow inside the channel which leads to the increase in heat transfer rate. Finally, Nusselt number, overall thermal resistance and maximum temperature of the heat sink were calculated to compare the performances of the modified heat sinks with the conventional mini channel heat sink and it was observed that the heat sink with both interconnectors and obstacles enhanced the thermal performance more significantly than other configurations. A maximum of 36% increase in Nusselt number was observed (for Re =1044).


Sign in / Sign up

Export Citation Format

Share Document