scholarly journals UV-Assisted Multiscale Superhydrophobic Wood Resisting Surface Contamination and Failure

ACS Omega ◽  
2021 ◽  
Vol 6 (40) ◽  
pp. 26732-26740
Author(s):  
Hong Yang ◽  
Jinxin Wang ◽  
Pengwei Zhao ◽  
Hongbo Mu ◽  
Dawei Qi
2002 ◽  
Author(s):  
M. Hoover ◽  
M. McCawley ◽  
D. Yereb ◽  
S. Tinkle ◽  
S. Beaton ◽  
...  

Author(s):  
Hua Younan

Abstract A failure analysis flow is developed for surface contamination, corrosion and underetch on microchip Al bondpads and it is applied in wafer fabrication. SEM, EDX, Auger, FTIR, XPS and TOF-SIMS are used to identify the root causes. The results from carbon related contamination, galvanic corrosion, fluorine-induced corrosion, passivation underetch and Auger bondpad monitoring will be presented. The failure analysis flow will definitely help us to select suitable methods and tools for failure analysis of Al bondpad-related issues, identify rapidly possible root causes of the failures and find the eliminating solutions at both wafer fabrication and assembly houses.


Author(s):  
Tran Thi Bao Le ◽  
Candice Divine-Ayela ◽  
Alberto Striolo ◽  
David R. Cole

Understanding the wetting properties of reservoir rocks can be of great benefit for advanced applications such as the effective trapping and geological storage of CO2. Despite their importance, not all...


2021 ◽  
pp. 107815522110235
Author(s):  
Hao ML ◽  
Wang T ◽  
Zhu JQ ◽  
Song YJ ◽  
Gong TJ ◽  
...  

Objectives The aims of the study were to evaluate the external contamination of hazardous drug vials used in Chinese hospitals and to compare environmental contamination generated by a robotic intelligent dispensing system (WEINAS) and a manual compounding procedure using a biological safety cabinet (BSC). Methods Cyclophosphamide, fluorouracil, and gemcitabine were selected as the representative hazardous drugs to monitor surface contamination of vials. In the comparative analysis of environmental contamination from manual and robotic compounding, wipe samples were taken from infusion bags, gloves, and the different locations of the BSC and the WEINAS robotic system. In this study, high-performance liquid chromatography coupled with double mass spectrometer (HPLC-MS/MS) was employed for sample analysis. Results (1) External contamination was measured on vials of all three hazardous drugs. The contamination detected on fluorouracil vials was the highest with an average amount up to 904.33 ng/vial, followed by cyclophosphamide (43.51 ng/vial), and gemcitabine (unprotected vials of 5.92 ng/vial, protected vials of 0.66 ng/vial); (2) overall, the environmental contamination induced by WEINAS robotic compounding was significantly reduced compared to that by manual compounding inside the BSC. Particularly, compared with manual compounding, the surface contamination on the infusion bags during robotic compounding was nearly nine times lower for cyclophosphamide (10.62 ng/cm2 vs 90.43 ng/cm2), two times lower for fluorouracil (3.47 vs 7.52 ng/cm2), and more than 23 times lower for gemcitabine (2.61 ng/cm2 vs 62.28 ng/cm2). Conclusions The external contamination occurred extensively on some hazardous drug vials that commonly used in Chinese hospitals. Comparison analysis for both compounding procedures revealed that robotic compounding can remarkably reduce environmental contamination.


Sign in / Sign up

Export Citation Format

Share Document