scholarly journals Development of Indirect Competitive Enzyme-Linked Immunosorbent Assay and Lateral-Flow Immunochromatographic Strip for the Detection of Digoxin in Human Blood

ACS Omega ◽  
2020 ◽  
Vol 5 (3) ◽  
pp. 1371-1376 ◽  
Author(s):  
Fanqian Ling ◽  
Liqiang Liu ◽  
Hua Kuang ◽  
Gang Cui ◽  
Chuanlai Xu
The Analyst ◽  
2021 ◽  
Author(s):  
Mengjia chao ◽  
Xin-Xin Xu ◽  
Liqiang Liu ◽  
aihong wu ◽  
Shanshan Song ◽  
...  

We prepared monoclonal antibodies (mAbs) against diminazene and used them in the development of a gold nanoparticle-based lateral-flow test (GNT) strip and indirect competitive enzyme-linked immunosorbent assay for the detection...


2020 ◽  
Vol 58 (9) ◽  
Author(s):  
Katharina Ziegler ◽  
Anca Rath ◽  
Christoph Schoerner ◽  
Renate Meyer ◽  
Thomas Bertsch ◽  
...  

ABSTRACT Diagnosis of Lyme neuroborreliosis (LNB) is challenging, as long as Borrelia-specific intrathecal antibodies are not yet detectable. The chemokine CXCL13 is elevated in the cerebrospinal fluid (CSF) of LNB patients. Here, we compared the performances of the Euroimmun CXCL13 enzyme-linked immunosorbent assay (CXCL13 ELISA) and the ReaScan CXCL13 lateral flow immunoassay (CXCL13 LFA), a rapid point-of-care test, to support the diagnosis of LNB. In a dual-center case-control study, CSF samples from 90 patients (34 with definite LNB, 10 with possible LNB, and 46 with other central nervous system [CNS] diseases [non-LNB group]) were analyzed with the CXCL13 ELISA and the CXCL13 LFA. Classification of patients followed the European Federation of Neurological Societies (EFNS) guidelines on LNB. The CXCL13 ELISA detected elevated CXCL13 levels in all patients with definite LNB (median, 1,409 pg/ml) compared to the non-LNB controls (median, 20.7 pg/ml; P < 0.0001), with a sensitivity of 100% and a specificity of 84.8% (cutoff value, 78.6 pg/ml; area under the receiver operating characteristic [ROC] curve, 0.93). Similarly, the CXCL13 LFA yielded elevated CXCL13 levels in 31 patients with definite LNB (median arbitrary value, 223.5) compared to the non-LNB control patients (median arbitrary value, 0; P < 0.0001) and had a sensitivity and specificity of 91.2% and 93.5%, respectively (cutoff arbitrary value, 22.5; area under the ROC curve, 0.94). The correlation between the CXCL13 levels obtained by ELISA and LFA was strong (Spearman correlation coefficient r = 0.89; P < 0.0001). The CXCL13 ELISA and the CXCL13 LFA are comparable diagnostic tools for the detection of CXCL13 in the CSF of patients with definite LNB. The advantage of the CXCL13 LFA is the shorter time to result.


2018 ◽  
Vol 34 (1) ◽  
pp. 51-56 ◽  
Author(s):  
Masanori ISHII ◽  
Pattarachaya PREECHAKASEDKIT ◽  
Kentaro YAMADA ◽  
Orawon CHAILAPAKUL ◽  
Koji SUZUKI ◽  
...  

2016 ◽  
Vol 54 (6) ◽  
pp. 1557-1565 ◽  
Author(s):  
Martin Heller ◽  
Nimmo Gicheru ◽  
Georgina Tjipura-Zaire ◽  
Cecilia Muriuki ◽  
Mingyan Yu ◽  
...  

Contagious bovine pleuropneumonia (CBPP) is a severe respiratory disease that is widespread in sub-Saharan Africa. It is caused byMycoplasma mycoidessubsp.mycoides, a bacterium belonging to theMycoplasma mycoidescluster. In the absence of an efficient CBPP vaccine, improved and easy-to-use diagnostic assays for recurrent testing combined with isolation and treatment of positive animals represent an option for CBPP control in Africa. Here we describe the comprehensive screening of 17 immunogenicMycoplasma mycoidessubsp.mycoidesproteins using well-characterized bovine sera for the development of a novel cocktail enzyme-linked immunosorbent assay (ELISA) for laboratory use. Two recombinantMycoplasmaimmunogens, MSC_0136 and MSC_0636, were used to set up a standardized cocktail ELISA protocol. According to the results from more than 100 serum samples tested, the sensitivity and specificity of the novel cocktail ELISA were 85.6% and 96.4%, respectively, with an overall diagnostic accuracy comparable to that of the Office International des Epizooties (OIE)-prescribed serological assays. In addition, we provide a proof of principle for a field-applicable, easy-to-use commercially produced prototype lateral-flow test for rapid (<30-min) diagnosis of CBPP.


1996 ◽  
Vol 14 (12) ◽  
pp. 1653-1662 ◽  
Author(s):  
Tracy Jordan ◽  
Lee Walus ◽  
Alex Velickovic ◽  
Thomas Last ◽  
Susan Doctrow ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document