scholarly journals Based on atmospheric physics and ecological principle to assess the accuracies of field CO 2 /H 2 O measurements from infrared gas analyzers in closed‐path eddy‐covariance systems

2021 ◽  
Author(s):  
Xinhua Zhou ◽  
Tian Gao ◽  
Yunchao Pang ◽  
Hayden Mahan ◽  
Xiufen Li ◽  
...  
2009 ◽  
Vol 9 (21) ◽  
pp. 8365-8375 ◽  
Author(s):  
C. J. P. P. Smeets ◽  
R. Holzinger ◽  
I. Vigano ◽  
A. H. Goldstein ◽  
T. Röckmann

Abstract. Long term methane flux measurements have been mostly performed with plant or soil enclosure techniques on specific components of an ecosystem. New fast response methane analyzers make it possible to use the eddy covariance (EC) technique instead. The EC technique is advantageous because it allows continuous flux measurements integrating over a larger and more representative area including the complete ecosystem, and allows fluxes to be observed as environmental conditions change naturally without disturbance. We deployed the closed-path Fast Methane analyzer (FMA) from Los Gatos Research Ltd and demonstrate its performance for EC measurements at a Ponderosa pine plantation at the Blodgett Forest site in central California. The fluctuations of the CH4 concentration measured at 10 Hz appear to be small and their standard deviation is comparable to the magnitude of the signal noise (±5 ppbv). Consequently, the power spectra typically have a white noise signature at the high frequency end (a slope of +1). Nevertheless, in the frequency range important for turbulent exchange, the cospectra of CH4 compare very well with all other scalar cospectra confirming the quality of the FMA measurements are good for the EC technique. We furthermore evaluate the complications of combined open and closed-path measurements when applying the Webb-Pearman-Leuning (WPL) corrections (Webb et al., 1980) and the consequences of a phase lag between the water vapor and methane signal inside the closed path system. The results of diurnal variations of CH4 concentrations and fluxes are summarized and compared to the monthly results of process-based model calculations.


2018 ◽  
Vol 11 (11) ◽  
pp. 6075-6090 ◽  
Author(s):  
Brian J. Butterworth ◽  
Brent G. T. Else

Abstract. The Arctic marine environment plays an important role in the global carbon cycle. However, there remain large uncertainties in how sea ice affects air–sea fluxes of carbon dioxide (CO2), partially due to disagreement between the two main methods (enclosure and eddy covariance) for measuring CO2 flux (FCO2). The enclosure method has appeared to produce more credible FCO2 than eddy covariance (EC), but is not suited for collecting long-term, ecosystem-scale flux datasets in such remote regions. Here we describe the design and performance of an EC system to measure FCO2 over landfast sea ice that addresses the shortcomings of previous EC systems. The system was installed on a 10 m tower on Qikirtaarjuk Island – a small rock outcrop in Dease Strait located roughly 35 km west of Cambridge Bay, Nunavut, in the Canadian Arctic Archipelago. The system incorporates recent developments in the field of air–sea gas exchange by measuring atmospheric CO2 using a closed-path infrared gas analyzer (IRGA) with a dried sample airstream, thus avoiding the known water vapor issues associated with using open-path IRGAs in low-flux environments. A description of the methods and the results from 4 months of continuous flux measurements from May through August 2017 are presented, highlighting the winter to summer transition from ice cover to open water. We show that the dried, closed-path EC system greatly reduces the magnitude of measured FCO2 compared to simultaneous open-path EC measurements, and for the first time reconciles EC and enclosure flux measurements over sea ice. This novel EC installation is capable of operating year-round on solar and wind power, and therefore promises to deliver new insights into the magnitude of CO2 fluxes and their driving processes through the annual sea ice cycle.


2016 ◽  
Author(s):  
I. Mammarella ◽  
O. Peltola ◽  
A. Nordbo ◽  
L. Järvi ◽  
Ü. Rannik

Abstract. We have carried out an inter-comparison between EddyUH and EddyPro®, two public software packages for post-field processing of eddy covariance data. Datasets including carbon dioxide, methane and water vapour fluxes measured over two months at a wetland in Southern Finland and carbon dioxide and water vapour fluxes measured over three months at an urban site in Helsinki, were processed and analysed. The purpose was to estimate the flux uncertainty due to the use of different software packages and to evaluate the most critical processing steps, determining the largest deviations in the calculated fluxes. Turbulent fluxes calculated with a reference combination of processing steps were in good agreement, the systematic difference between the two software packages being up to 2% and 6.7% for half-hour and cumulative sum values, respectively. The raw data preparation and processing steps were consistent between the software packages, and most of the deviations in the estimated fluxes were due to the flux corrections. Among the different calculation procedures analysed, the spectral correction had biggest impact for closed-path latent heat fluxes, reaching nocturnal median value of 15% at the wetland site. We found up to 43% median value of deviation (with respect to the run with all corrections included) if closed path carbon dioxide flux is calculated without the dilution correction, while the methane fluxes were up to 10% lower without both dilution and spectroscopic corrections. The density (and spectroscopic) correction was the most critical step for open-path systems. However, we found also large spectral correction factors for the open-path methane fluxes, due to the sensor separation effect.


2021 ◽  
Author(s):  
Xinhua Zhou ◽  
Tian Gao ◽  
Eugene S. Takle ◽  
Xiaojie Zhen ◽  
Andrew E. Suyker ◽  
...  

Abstract. Air temperar (T) plays a fundamental role in many aspects of the flux exchanges between the atmosphere and ecosystems. Additionally, it is critical to know where (in relation to other essential measurements) and at what frequency T must be measured to accurately describe such exchanges. In closed-path eddy-covariance (CPEC) flux systems, T can be computed from the sonic temperature (Ts) and water vapor mixing ratio that are measured by the fast-response senosrs of three-dimensional sonic anemometer and infrared gas analyzer, respectively. T then is computed by use of either T = Ts (1 + 0.51q)−1, where q is specific humidity, or T = Ts (1 + 0.32e / P)−1, where e is water vapor pressure and P is atmospheric pressure. Converting q and e / P into the same water vapor mixing ratio analytically reveals the difference between these two equations. This difference in a CPEC system could reach ±0.18 K, bringing an uncertainty into the accuracy of T from both equations and raises the question of which equation is better. To clarify the uncertainty and to answer this question, the derivation of T equations in terms of Ts and H2O-related variables is thoroughly studied. The two equations above were developed with approximations. Therefore, neither of their accuracies were evaluated, nor was the question answered. Based on the first principles, this study derives the T equation in terms of Ts and water vapor molar mixing ratio (χH2O) without any assumption and approximation. Thus, this equation itself does not have any error and the accuracy in T from this equation (equation-computed T) depends solely on the measurement accuracies of Ts and χH2O. Based on current specifications for Ts and χH2O in the CPEC300 series and given their maximized measurement uncertainties, the accuracy in equation-computed T is specified within ±1.01 K. This accuracy uncertainty is propagated mainly (±1.00 K) from the uncertainty in Ts measurements and little (±0.03 K) from the uncertainty in χH2O measurements. Apparently, the improvement on measurement technologies particularly for Ts would be a key to narrow this accuracy range. Under normal sensor and weather conditions, the specified accuracy is overestimated and actual accuracy is better. Equation-computed T has frequency response equivalent to high-frequency Ts and is insensitive to solar contamination during measurements. As synchronized at a temporal scale of measurement frequency and matched at a spatial scale of measurement volume with all aerodynamic and thermodynamic variables, this T has its advanced merits in boundary-layer meteorology and applied meteorology.


Tellus B ◽  
2012 ◽  
Vol 64 (1) ◽  
pp. 19048 ◽  
Author(s):  
Masahito Ueyama ◽  
Ryuichi Hirata ◽  
Masayoshi Mano ◽  
Ken Hamotani ◽  
Yoshinobu Harazono ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document