scholarly journals Comparison of Velocity- and Acceleration-Selective Arterial Spin Labeling with [15O]H2O Positron Emission Tomography

2015 ◽  
Vol 35 (8) ◽  
pp. 1296-1303 ◽  
Author(s):  
Sophie Schmid ◽  
Dennis FR Heijtel ◽  
Henri JMM Mutsaerts ◽  
Ronald Boellaard ◽  
Adriaan A Lammertsma ◽  
...  

In the last decade spatially nonselective arterial spin labeling (SNS-ASL) methods such as velocity-selective ASL (VS-ASL) and acceleration-selective ASL have been introduced, which label spins based on their flow velocity or acceleration rather than spatial localization. Since labeling also occurs within the imaging plane, these methods suffer less from transit delay effects than traditional ASL methods. However, there is a need for validation of these techniques. In this study, a comparison was made between these SNS-ASL techniques with [15O]H2O positron emission tomography (PET), which is regarded as gold standard to measure quantitatively cerebral blood flow (CBF) in humans. In addition, the question of whether these techniques suffered from sensitivity to arterial cerebral blood volume (aCBV), as opposed to producing pure CBF contrast, was investigated. The results show high voxelwise intracranial correlation (0.72 to 0.89) between the spatial distribution of the perfusion signal from the SNS-ASL methods and the PET CBF maps. A similar gray matter (GM) CBF was measured by dual VS-ASL compared with PET (46.7 ± 4.1 versus 47.1 ± 6.5 mL/100 g/min, respectively). Finally, only minor contribution of aCBV patterns in GM to all SNS-ASL methods was found compared with pseudo-continuous ASL. In conclusion, VS-ASL provides a similar quantitative CBF, and all SNS-ASL methods provide qualitatively similar CBF maps as [15O]H2O PET.

2016 ◽  
Vol 36 (5) ◽  
pp. 842-861 ◽  
Author(s):  
Audrey P Fan ◽  
Hesamoddin Jahanian ◽  
Samantha J Holdsworth ◽  
Greg Zaharchuk

Noninvasive imaging of cerebral blood flow provides critical information to understand normal brain physiology as well as to identify and manage patients with neurological disorders. To date, the reference standard for cerebral blood flow measurements is considered to be positron emission tomography using injection of the [15O]-water radiotracer. Although [15O]-water has been used to study brain perfusion under normal and pathological conditions, it is not widely used in clinical settings due to the need for an on-site cyclotron, the invasive nature of arterial blood sampling, and experimental complexity. As an alternative, arterial spin labeling is a promising magnetic resonance imaging technique that magnetically labels arterial blood as it flows into the brain to map cerebral blood flow. As arterial spin labeling becomes more widely adopted in research and clinical settings, efforts have sought to standardize the method and validate its cerebral blood flow values against positron emission tomography-based cerebral blood flow measurements. The purpose of this work is to critically review studies that performed both [15O]-water positron emission tomography and arterial spin labeling to measure brain perfusion, with the aim of better understanding the accuracy and reproducibility of arterial spin labeling relative to the positron emission tomography reference standard.


2009 ◽  
Vol 30 (1) ◽  
pp. 222-229 ◽  
Author(s):  
Reinoud PH Bokkers ◽  
Jochem P Bremmer ◽  
Bart NM van Berckel ◽  
Adriaan A Lammertsma ◽  
Jeroen Hendrikse ◽  
...  

Arterial spin labeling (ASL) perfusion magnetic resonance imaging (MRI) with image acquisition at multiple inversion times is a noninvasive ASL technique able to compensate for spatial heterogeneities in transit times caused by collateral blood flow in patients with severe stenosis of the cerebropetal blood vessels. Our aim was to compare ASL-MRI and H215O positron emission tomography (PET), the gold standard for cerebral blood flow (CBF) assessment, in patients with a symptomatic internal carotid artery (ICA) occlusion. Fourteen patients (63±14 years) with a symptomatic ICA occlusion underwent both ASL-MRI and H215O PET. The ASL-MRI was performed using a pulsed STAR labeling technique at multiple inversion times within 7 days of the PET. The CBF was measured in the gray-matter of the anterior, middle and posterior cerebral artery, and white-matter. Both PET and ASL-MRI showed a significantly decreased CBF in the gray-matter of the middle cerebral artery in the hemisphere ipsilateral to the ICA occlusion. The average gray-matter CBF measured with ASL-MRI (71.8±4.3 mL/min/100 g) was higher ( P<0.01) than measured with H215O PET (43.1±1.0 mL/min/100 g). In conclusion, ASL-MRI at multiple TIs is capable of depicting areas of regions with low CBF in patients with an occlusion of the ICA, although a systematic overestimation of CBF relative to H215O PET was noted.


2018 ◽  
Vol 39 (1) ◽  
pp. 173-181 ◽  
Author(s):  
Masanobu Ibaraki ◽  
Kazuhiro Nakamura ◽  
Hideto Toyoshima ◽  
Kazuhiro Takahashi ◽  
Keisuke Matsubara ◽  
...  

Pseudo-continuous arterial spin labeling (pCASL) is a completely non-invasive method of cerebral perfusion measurement. However, cerebral blood flow (CBF) quantification is hampered by arterial transit artifacts characterized by bright vascular signals surrounded by decreased signals in tissue regions, which commonly appear in patients with reduced cerebral perfusion pressure. The spatial coefficient of variation (CoV) of pCASL CBF images has been proposed as an alternative region-of-interest (ROI)-based hemodynamic measure to predict prolonged arterial transit time (ATT). This retrospective study investigates the utility of spatial CoV by comparison with 15O positron emission tomography (PET). For patients with cerebrovascular steno-occlusive disease ( n = 17), spatial CoV was positively correlated with ATT independently measured by pulsed arterial spin labeling ( r = 0.597, p < 0.001), confirming its role as an ATT-like hemodynamic measure. Comparisons with 15O PET demonstrated that spatial CoV was positively correlated with vascular mean transit time ( r = 0.587, p < 0.001) and negatively correlated with both resting CBF ( r = −0.541, p = 0.001) and CBF response to hypercapnia ( r = −0.373, p = 0.030). ROI-based spatial CoV calculated from single time-point pCASL can potentially detect subtle perfusion abnormalities in clinical settings.