Long-term outcome of endovascular therapy for ischaemic stroke

2017 ◽  
Vol 13 (7) ◽  
pp. 387-388
Author(s):  
Charlotte Zerna ◽  
Mayank Goyal
Stroke ◽  
2020 ◽  
Vol 51 (Suppl_1) ◽  
Author(s):  
Issei Kan ◽  
Toshihiro Ishibashi ◽  
Ichiro Yuki ◽  
Masayuki Ebara ◽  
Hideki Arakawa ◽  
...  

Objectives: Long term outcome of large / giant unruptured intracranial aneurysms (LG-UIAs) after endovascular therapy is still unknown. We retrospectively analyzed long-term results of patients with LG-UIAs who were followed up more than 5 years after endovascular therapy. Methods: We included patients from our complete database with UIAs greater than 10mm and treated at our hospital from January 2003 to December 2013. Retreatment rate of targeted aneurysms, rupture rate, and the modified Rankin scale (mRS) at last visit were evaluated till December 2018. Results: From 142 patients treated during the period were excluded 3 patients with perioperative rupture and 38 patients with less than 5 years follow-up period, finally analyzing 101 patients. The median aneurysm size was 12.0 mm (IQR 10.8-15). The median follow-up period was 9.4 years (IQR: 7-11), the longest being 13.3 years. Retreatment was performed on 36 patients (35.6%). Comparing cumulative re-treatment rates in groups with aneurysm sizes <15 mm and> 20 mm, it was predominantly higher for aneurysms> 20 mm (P = 0.02, Figure1 ). Rupture of targeted aneurysms was observed in 2 cases (1.98%, Figure2 ), and the longest period from last treatment was up to 12 years. The mRS 0-1 at the first treatment and the final visit were 98% and 93%, respectively, and mRS deterioration remained at 5%. Conclusion: The retreatment rate tended to increase in proportion to the size of the aneurysm, however the final neurological outcome was favorable when considering the natural history of these aneurysms. Since aneurysmal rupture could occur after 12 years of treatment, long-term follow-up should be considered for LG-UIAs.


2015 ◽  
Vol 114 (09) ◽  
pp. 614-622 ◽  
Author(s):  
Young Dae Kim ◽  
Dongbeom Song ◽  
Hyo Suk Nam ◽  
Kijeong Lee ◽  
Joonsang Yoo ◽  
...  

SummaryPatent foramen ovale (PFO) is a potential cause of cryptogenic stroke, given the possibility of paradoxical embolism from venous to systemic circulation. D-dimer level is used to screen venous thrombosis. We investigated the risk of embolism and mortality according to the presence of PFO and D-dimer levels in cryptogenic stroke patients. A total of 570 first-ever cryptogenic stroke patients who underwent transesophageal echocardiography were included in this study. D-dimer was assessed using latex agglutination assay during admission. The association of long-term outcomes with the presence of PFO and D-dimer levels was investigated. PFO was detected in 241 patients (42.3 %). During a mean 34.0 ± 22.8 months of follow-up, all-cause death occurred in 58 (10.2 %) patients, ischaemic stroke in 33 (5.8 %), and pulmonary thromboembolism in 6 (1.1 %). Multivariate Cox regression analysis showed that a D-dimer level of > 1,000 ng/ml was an independent predictor for recurrent ischaemic stroke in patients with PFO (hazard ratio 5.341, 95 % confidence interval 1.648–17.309, p=0.005), but not in those without PFO. However, in patients without PFO, a D-dimer level of > 1,000 ng/ml was independently related with all-cause mortality. The risk of pulmonary thromboembolism tended to be high in patients with high D-dimer levels, regardless of PFO. Elevated D-dimer levels in cryptogenic stroke were predictive of the long-term outcome, which differed according to the presence of PFO. The coexistence of PFO and a high D-dimer level increased the risk of recurrent ischaemic stroke. The D-dimer test in cryptogenic stroke patients may be useful for predicting outcomes and deciding treatment strategy.


PLoS ONE ◽  
2020 ◽  
Vol 15 (4) ◽  
pp. e0231261
Author(s):  
Lorenz Ertl ◽  
Hartmut Brückmann ◽  
Maximilian Patzig ◽  
Franziska Dorn ◽  
Gunther Fesl

2014 ◽  
Vol 78 (2) ◽  
pp. 457-464 ◽  
Author(s):  
Hideaki Aihara ◽  
Yoshimitsu Soga ◽  
Shinsuke Mii ◽  
Jin Okazaki ◽  
Terutoshi Yamaoka ◽  
...  

2008 ◽  
Vol 15 (4) ◽  
pp. 408-416 ◽  
Author(s):  
Sebastian Sixt ◽  
Abdul Karim Alawied ◽  
Aljoscha Rastan ◽  
Uwe Schwarzwälder ◽  
Martin Kleim ◽  
...  

Angiology ◽  
2017 ◽  
Vol 69 (4) ◽  
pp. 308-315 ◽  
Author(s):  
Arne M. Müller ◽  
Nicolas Langwieser ◽  
Christian Bradaric ◽  
Bernhard Haller ◽  
Massimiliano Fusaro ◽  
...  

We evaluated safety and long-term outcome of endovascular therapy for steno-occlusive iliac artery disease. All endovascular procedures of iliac artery lesions performed at our institution between 2001 and 2014 (n = 676) were retrospectively analyzed. The overall technical success rate was 99% and yielded 100% for stenoses (n = 596) and 95% for chronic total occlusions (n = 80). Lesion complexity defined by the Trans-Atlantic Inter-Society Consensus (TASC) II classification had no impact on success rates (TASC A + B vs C + D; 99.5% vs 98.6%, P = .359). During a median follow-up of 11 months, the overall rate of restenosis was 9.4%. After 1 and 3 years, the primary patency rates were 94% and 86% and the secondary patency rate was 100%, respectively. The TASC II classification had no impact on long-term patency rates (TASC A + B vs C + D; 86% vs 81%). In a multivariable analysis, stent diameter remained the only significant predictor for restenosis (hazard ratio: 0.58; 95% confidence interval: 0.41%-0.81%; P = .002). In this single-center retrospective study, endovascular therapy for steno-occlusive iliac artery disease was associated with high technical and clinical success rates as well as an excellent long-term patency rate irrespective of lesion complexity.


Sign in / Sign up

Export Citation Format

Share Document