scholarly journals Monocyte HLA-DR expression and neutrophil CD64 expression as biomarkers of infection in critically ill neonates and infants

2015 ◽  
Vol 78 (6) ◽  
pp. 683-690 ◽  
Author(s):  
Justin E. Juskewitch ◽  
Roshini S. Abraham ◽  
Stacy C. League ◽  
Sarah M. Jenkins ◽  
Carin Y. Smith ◽  
...  
2016 ◽  
Vol 38 (1) ◽  
pp. 149-154
Author(s):  
Jon Kaufman ◽  
Daniel Phadke ◽  
Suhong Tong ◽  
Jennifer Eshelman ◽  
Sarah Newman ◽  
...  

2002 ◽  
Vol 48 (11) ◽  
pp. 2030-2043 ◽  
Author(s):  
Glenn F Billman ◽  
Amy B Hughes ◽  
Golde G Dudell ◽  
Elizabeth Waldman ◽  
Lisa M Adcock ◽  
...  

Abstract Background: The management of critically ill infants and neonates includes frequent determination of arterial blood gas, electrolyte, and hematocrit values. An objective of attached point-of-care patient monitoring is to provide clinically relevant data without the adverse consequences associated with serial phlebotomy. Methods: We prospectively determined the mean difference (and SD of the difference) from laboratory methods of an in-line, ex vivo monitor, the VIA LVM Blood Gas and Chemistry Monitoring System® (VIA LVM Monitor; Metracor Technologies, Inc.), in 100 critically ill neonates and infants at seven children’s hospitals. In doing so, we examined monitor stability with continuous use. In vivo patient test results from laboratory benchtop analyzers were compared with those from the VIA LVM Monitor on paired samples. In a separate in vitro comparison, benchtop analyzer and monitor test results were compared on whole-blood split samples. Results: A total of 1414 concurrent, paired-sample measurements were obtained. The mean differences (SD of differences) from laboratory methods and r values for the combined data for the VIA LVM Monitor from the seven sites were 0.001 (0.026) and 0.97 for pH, 0.7 (3.6) mmHg and 0.94 for Pco2, 4.2 (9.6) mmHg and 0.98 for Po2, 0.0 (2.9) mmol/L and 0.87 for sodium, 0.1 (0.2) mmol/L and 0.96 for potassium, and 0.3% (2.9%) and 0.90 for hematocrit. Performance results were similar among the study sites with increasing time of monitor use and between in vivo paired-sample and in vitro split-sample test results. Conclusion: The VIA LVM Monitor can be used to assess critically ill neonates and infants.


2012 ◽  
Vol 33 (7) ◽  
pp. 1069-1077 ◽  
Author(s):  
Francis Lam ◽  
Adnan T. Bhutta ◽  
Joseph D. Tobias ◽  
Jeffrey M. Gossett ◽  
Laura Morales ◽  
...  

2008 ◽  
Vol 63 (6) ◽  
pp. 674-679 ◽  
Author(s):  
Karel Allegaert ◽  
Ron H N van Schaik ◽  
Steve Vermeersch ◽  
Rene Verbesselt ◽  
Veerle Cossey ◽  
...  

2012 ◽  
Vol 38 (3) ◽  
pp. 445-452 ◽  
Author(s):  
Antoine Gros ◽  
Mikael Roussel ◽  
Elise Sauvadet ◽  
Arnaud Gacouin ◽  
Sophie Marqué ◽  
...  

Critical Care ◽  
2008 ◽  
Vol 12 (Suppl 2) ◽  
pp. P279 ◽  
Author(s):  
K Allegaert ◽  
R Verbesselt ◽  
R Van Schaik ◽  
J Van den Anker ◽  
C Vanhole ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document