scholarly journals Long-term surgical outcomes of primary retropupillary iris claw intraocular lens implantation for the treatment of intraocular lens dislocation

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Eun Young Choi ◽  
Chul Hee Lee ◽  
Hyun Goo Kang ◽  
Jae Yong Han ◽  
Suk Ho Byeon ◽  
...  

AbstractWe aimed to investigate the efficacy and safety of primary retropupillary iris claw intraocular lens (R-IOL) implantation in patients with complete intraocular lens (IOL) dislocation. In this single-center retrospective case series, we reviewed the medical records of patients who underwent R-IOL implantation surgery with pars plana vitrectomy for the treatment of IOL dislocation between September 2014 and July 2019. The primary outcome was change in visual acuity (VA) up to 24 months postoperatively. The secondary outcomes included changes in intraocular pressure (IOP), refractive errors, and endothelial cell count (ECC) over the same period. Data of 103 eyes (98 patients) were analyzed. The mean uncorrected VA was significantly improved at one month postoperatively (− 0.69 logMAR, P < 0.001), compared to the preoperative value. IOP (− 2.3 mmHg, P = 0.008) and ECC (− 333.4 cells/mm2, P = 0.027) significantly decreased one month post-surgery and remained stable thereafter. Postoperative mean spherical equivalents were similar to the prediction error throughout the follow-up period. IOP elevation (n = 8, 7.8%), cystoid macular edema (n = 4, 3.9%), and dislocation of the R-IOL (n = 10, 9.7%) were managed successfully. Overall, primary R-IOL implantation with pars plana vitrectomy is effective and safe for correcting IOL dislocation due to various causes.

2016 ◽  
Vol 7 (3) ◽  
pp. 433-439
Author(s):  
Spyridon E. Chalkiadakis ◽  
Efstratios A. Parikakis ◽  
Simon R.J. Taylor

Background: The surgical case of a dropped intraocular lens inside the vitreous cavity constitutes a real challenge for the operating surgeon. Herein, we describe a case series where an alternative optical rehabilitation technique for late intraocular lens-bag complex dislocation has been used. Methods: A modern vitrectomy device was used to remove the capsule with the dropped intraocular lens using sutureless 25-gauge pars plana vitrectomy. To ensure a better aesthetic result, with faster patient recovery and a reduced number of operations, the whole procedure was performed during the same operating session; an iris-claw intraocular lens for aphakia was selected for implantation. The implant was passed behind the constricted iris with the concave surface facing it. The lens was grasped with the manufacturer’s holding forceps and fixed onto the posterior surface of the iris using the special enclavation needles. Results: We have operated 12 eyes in two different clinical centres successfully, with minimal intra- and/or postoperative complications. Conclusion: We believe that this is a viable solution for the visual rehabilitation of patients, who would otherwise need more than one operation for a lens exchange.


2020 ◽  
Author(s):  
Takahiko Hayashi ◽  
Yasutsugu Ida ◽  
Toshiki Shimizu ◽  
Tsubasa Kuroki ◽  
Yuji Kobashigawa ◽  
...  

Abstract Background The aim of this study was to evaluate the clinical outcomes of pars plana vitrectomy (PPV) combined with penetrating keratoplasty (PKP) and transscleral-sutured intraocular lens (IOL) implantation (IOL-suture) in complex eyes.Methods In this prospective, consecutive interventional case series, patients who underwent PKP combined with PPV and IOL implantation from July 2014 to March 2018 at Yokohama Minami Kyosai Hospital were enrolled. The postoperative best corrected visual acuity (BCVA) (converted to logarithm of the minimal angle of resolution [logMAR] units), intraocular pressure (IOP, mmHg), endothelial cell density (ECD, cells/mm2), graft survival, complications, astigmatism, and spherical equivalent (dioptres [D]) were evaluated. Results This study included 11 eyes of 11 patients (three females and eight males; mean age, 61.8 ± 13.9 years) with an injury (n = 6) or bullous keratopathy (n = 5). The BCVA significantly improved from 1.50 ± 0.66 logMAR preoperatively to 0.78 ± 0.59 logMAR (p < 0.001) postoperatively. The baseline ECD significantly decreased from 2396 ± 238 cells/mm2 preoperatively to 1132 ± 323 cells/mm2 (p < 0.001) postoperatively. Despite two rejection episodes, graft survival rates were 100%. The mean follow-up period was 38.0 ± 20.5 months. Two patients required combined glaucoma surgery, and three patients underwent subsequent glaucoma surgery. Postoperative astigmatism and spherical equivalent were 3.9 ± 3.2 D and 0.29 ± 2.18 D, respectively.Conclusion The combination of PKP, PPV, and IOL-suture implantation could be a safe and effective approach for eyes requiring anterior segment surgery; however, these eyes are associated with a higher incidence of glaucoma surgery.


2021 ◽  
Vol 2 (3) ◽  
pp. 127-130
Author(s):  
Jin Yang ◽  
◽  
Xiao-Di Qiu ◽  
Lei Cai ◽  
Yi Lu ◽  
...  

AIM: To describe a technique of managing intraocular lens (IOL) with deep dislocation in the vitreous cavity by performing pars plana vitrectomy (PPV) with only one pars plana incision under the direct illumination of the surgical microscope. METHODS: Patients who had in-the-bag or out-of-the-bag (spontaneous) IOL dislocation after uneventful phacoemulsification cataract extractions, with the dislocated IOL or IOL-capsular bag complex dropping completely into the vitreous since 2013 were included in our studies. The postoperative patients were followed up for 6mo. Detailed description of technique and retrospective description of eight typical cases were demonstrated in this study. RESULTS: A total of 40 surgeries were conducted using this technique. The main possible predisposing conditions included: post-vitrectomy, posterior capsule rupture or broken zonules, a history of ocular trauma, long axial length, secondary IOL implantation, chronic uveitis, retinitis pigmentosa and post-glaucoma surgery. In all eyes, the IOLs were successfully removed. No intraoperative or postoperative complications related to the procedures occurred. The preoperative corrected distance visual acuity (CDVA) ranged from 20/133 to 20/25, and at 6mo postoperatively, the CDVA was similar or the same. The intraocular pressure was all within the normal range. CONCLUSION: One-port PPV under direct vision with microscope illumination is a simple and safe surgical technique to managing IOL dislocation, which shortens the surgical time, and largely avoids surgical complications.


2020 ◽  
Vol 20 (1) ◽  
Author(s):  
Takahiko Hayashi ◽  
Ida Yasutsugu ◽  
Toshiki Shimizu ◽  
Tsubasa Kuroki ◽  
Yuji Kobashigawa ◽  
...  

Abstract Background The aim of this study was to evaluate the clinical outcomes of pars plana vitrectomy (PPV) combined with penetrating keratoplasty (PKP) and transscleral-sutured intraocular lens (IOL) implantation (IOL-suture) in complex eyes. Methods In this prospective, consecutive interventional case series, patients who underwent PKP combined with PPV and IOL implantation from July 2014 to March 2018 at Yokohama Minami Kyosai Hospital were enrolled. The postoperative best corrected visual acuity (BCVA) (converted to logarithm of the minimal angle of resolution [logMAR] units), intraocular pressure (IOP, mmHg), endothelial cell density (ECD, cells/mm2), graft survival, complications, astigmatism, and spherical equivalent (dioptres [D]) were evaluated. Results This study included 11 eyes of 11 patients (three females and eight males; mean age, 61.8 ± 13.9 years) with an injury (n = 6) or bullous keratopathy (n = 5). The BCVA significantly improved from 1.50 ± 0.66 logMAR preoperatively to 0.78 ± 0.59 logMAR (p < 0.001) postoperatively. The baseline ECD significantly decreased from 2396 ± 238 cells/mm2 preoperatively to 1132 ± 323 cells/mm2 (p < 0.001) postoperatively. Despite two rejection episodes, graft survival rates were 100%. The mean follow-up period was 38.0 ± 20.5 months. Two patients required combined glaucoma surgery, and three patients underwent subsequent glaucoma surgery. Postoperative astigmatism and spherical equivalent were 3.9 ± 3.2 D and 0.29 ± 2.18 D, respectively. Conclusion The combination of PKP, PPV, and IOL-suture implantation could be a safe and effective approach for eyes requiring anterior segment surgery; however, these eyes are associated with a higher incidence of glaucoma surgery.


2020 ◽  
Author(s):  
Takahiko Hayashi ◽  
Yasutsugu Ida ◽  
Toshiki Shimizu ◽  
Tsubasa Kuroki ◽  
Yuji Kobashigawa ◽  
...  

Abstract Background The aim of this study was to evaluate the clinical outcomes of pars plana vitrectomy (PPV) combined with penetrating keratoplasty (PKP) and transscleral-sutured intraocular lens (IOL) implantation (IOL-suture) in complex eyes. Methods In this prospective, consecutive interventional case series, patients who underwent PKP combined with PPV and IOL implantation from July 2014 to Mar 2017 at Yokohama Minami Kyosai Hospital were enrolled. The postoperative best corrected visual acuity (BCVA) (converted to logarithm of the minimal angle of resolution [logMAR] units), intraocular pressure (IOP, mmHg), endothelial cell density (ECD, cells/mm2), graft survival, complications, astigmatism, and spherical equivalent (dioptres [D]) were evaluated. Results This study included 11 eyes of 11 patients (three females and eight males; mean age, 61.8 ± 13.9 years) with an injury (n = 6) or bullous keratopathy (n = 5). The BCVA significantly improved from 1.50 ± 0.66 logMAR preoperatively to 0.78 ± 0.59 logMAR (p < 0.001) postoperatively. The baseline ECD significantly decreased from 2396 ± 238 cells/mm2 preoperatively to 1132 ± 323 cells/mm2 (p < 0.001) postoperatively. Despite two rejection episodes, graft survival rates were 100%. The mean follow-up period was 38.0 ± 20.5 months. Two patients required combined glaucoma surgery, and three patients underwent subsequent glaucoma surgery. Postoperative astigmatism and the spherical equivalent were 3.9 ± 3.2 D and 0.29 ± 2.18 D, respectively. Conclusion The combination of PKP, PPV, and IOL-suture implantation could be a safe and effective approach for eyes requiring anterior segment surgery; however, these eyes are associated with a higher incidence of glaucoma surgery.


2021 ◽  
Vol 10 (6) ◽  
pp. 1199
Author(s):  
Bogumiła Sędziak-Marcinek ◽  
Adam Wylęgała ◽  
Elżbieta Chełmecka ◽  
Mateusz Marcinek ◽  
Edward Wylęgała

An iris-claw intraocular lens (IOL) has been widely used as a secondary implant in aphakic patients. The study presents the results of implanting the anterior chamber iris-claw Artisan IOL in cases of where an appropriate posterior capsular support is lacking. The study included 132 patients subjected to primary IOL implantation during complicated cataract surgery with damage to the posterior capsule (I), secondary implantation in aphakia (II), secondary implantation during penetrating keratoplasty (III), and secondary implantation during pars plana vitrectomy with luxated IOL extraction (IV). We analyzed the records of best-corrected visual acuity (BCVA), spherical equivalent (SE), intraocular pressure (IOP), and corneal endothelial cell count (cECC), taken before and 1, 2, 3, and 4 years after the surgery. BCVA depended on the time after IOL implantation and the primary indication. Four years post-surgery, the SE values were the lowest in group III. IOP was the same in all groups both before and after the surgery, but 4 years after the surgery IOP values in group IV were higher than in group III. The cECC decreased every year after the surgery in all groups, but four years after the IOL implantation, the lowest cECC values were observed in group IV. At the same time, all groups of patients showed improved BCVA, stable refraction, and a low percentage of postoperative complications.


2020 ◽  
Author(s):  
Takahiko Hayashi ◽  
Yasutsugu Ida ◽  
Toshiki Shimizu ◽  
Tsubasa Kuroki ◽  
Yuji Kobashigawa ◽  
...  

Abstract Background The aim of this study was to evaluate the clinical outcomes of pars plana vitrectomy (PPV) combined with penetrating keratoplasty (PKP) and transscleral-sutured intraocular lens (IOL) implantation (IOL-suture) in complex eyes.Methods In this prospective, consecutive interventional case series, patients who underwent PKP combined with PPV and IOL implantation from July 2014 to March 2018 at Yokohama Minami Kyosai Hospital were enrolled. The postoperative best corrected visual acuity (BCVA) (converted to logarithm of the minimal angle of resolution [logMAR] units), intraocular pressure (IOP, mmHg), endothelial cell density (ECD, cells/mm2), graft survival, complications, astigmatism, and spherical equivalent (dioptres [D]) were evaluated. Results This study included 11 eyes of 11 patients (three females and eight males; mean age, 61.8 ± 13.9 years) with an injury (n = 6) or bullous keratopathy (n = 5). The BCVA significantly improved from 1.50 ± 0.66 logMAR preoperatively to 0.78 ± 0.59 logMAR (p < 0.001) postoperatively. The baseline ECD significantly decreased from 2396 ± 238 cells/mm2 preoperatively to 1132 ± 323 cells/mm2 (p < 0.001) postoperatively. Despite two rejection episodes, graft survival rates were 100%. The mean follow-up period was 38.0 ± 20.5 months. Two patients required combined glaucoma surgery, and three patients underwent subsequent glaucoma surgery. Postoperative astigmatism and spherical equivalent were 3.9 ± 3.2 D and 0.29 ± 2.18 D, respectively.Conclusion The combination of PKP, PPV, and IOL-suture implantation could be a safe and effective approach for eyes requiring anterior segment surgery; however, these eyes are associated with a higher incidence of glaucoma surgery.


2018 ◽  
Vol 9 (1) ◽  
pp. 179-184
Author(s):  
Ratna Sitompul

Intraocular lens (IOL) dislocation is a rare complication of cataract extraction requiring prompt surgery. This case report aims to raise awareness of such cases and the importance of post-surgery follow-up. A 58-year-old female patient was found with anterior IOL dislocation a week after phacoemulsification surgery in her right eye. Visual acuity of the right eye was 1/60 with ciliary injection and IOL dislocation to the anterior chamber of the right eye. The patient underwent surgery of the right eye and the IOL haptic was found to be broken. In this case report, the factors affecting IOL dislocation are axis length, broken IOL haptic, and patient activity that increased intraocular pressure. Cataract extraction surgery, although common, needs to be conducted carefully, and it is important for ophthalmologists and general practitioners to detect this condition, especially in rural areas where facilities are limited, as IOL dislocation could occur and requires immediate treatment to achieve a better result.


2018 ◽  
Vol 3 (1) ◽  
pp. e000174
Author(s):  
Fabrizio Giansanti ◽  
Ruggero Tartaro ◽  
Tomaso Caporossi ◽  
Vittoria Murro ◽  
Alfonso Savastano ◽  
...  

ObjectiveIntraocular lens (IOL) repositioning using a closed-eye approach could be carried out in some selected cases. Our study focuses on the efficacy and safety of a IOL closed-eye repositioning technique using scleral suture, which is performed using a trocar as an intrastromal limbal guide.Methods and analysisThirty-one eyes of 31 patients with late IOL dislocation operated on between January 2015 and May 2017 were included in this retrospective non-comparative consecutive case series study. The patients had a single-piece in-the-bag dislocation or a 3-pieces in-the-bag or out-of-the-bag dislocation. The patients underwent an anterior vitrectomy and a scleral refixation in a closed chamber using a 10/0 polypropylene suture passed through a 25 Gauge trocar inserted in the anterior chamber.ResultsThe mean follow-up time was 19.54 months. Average preoperative best-corrected visual acuity (BCVA) was 0.73 LogMar (±0.21 SD); while average postoperative BCVA was 0.27 LogMar (±0.23 SD). Fifteen patients underwent anterior pars plana vitrectomy (PPV) while 16 patients did not; moreover, two patients underwent PPV. Six patients had an increase of postoperative intraocular pressure, two patients had postoperative decentration, two patients had postoperative cystoid macular oedema, none of the patients had major complications such as retinal detachment, choroidal detachment, malignant glaucoma, irreversible corneal decompensation and endophthalmitis.ConclusionWe can affirm that our technique may be safe and useful in the case of 3-piece in-the bag or out-of the bag dislocated IOLs and also in the case of in-the-bag single-piece dislocated IOLs.


Sign in / Sign up

Export Citation Format

Share Document