scholarly journals Intraocular lens dislocation: a novel in-situ scleral refixation technique using a 25 Gauge trocar in the anterior chamber

2018 ◽  
Vol 3 (1) ◽  
pp. e000174
Author(s):  
Fabrizio Giansanti ◽  
Ruggero Tartaro ◽  
Tomaso Caporossi ◽  
Vittoria Murro ◽  
Alfonso Savastano ◽  
...  

ObjectiveIntraocular lens (IOL) repositioning using a closed-eye approach could be carried out in some selected cases. Our study focuses on the efficacy and safety of a IOL closed-eye repositioning technique using scleral suture, which is performed using a trocar as an intrastromal limbal guide.Methods and analysisThirty-one eyes of 31 patients with late IOL dislocation operated on between January 2015 and May 2017 were included in this retrospective non-comparative consecutive case series study. The patients had a single-piece in-the-bag dislocation or a 3-pieces in-the-bag or out-of-the-bag dislocation. The patients underwent an anterior vitrectomy and a scleral refixation in a closed chamber using a 10/0 polypropylene suture passed through a 25 Gauge trocar inserted in the anterior chamber.ResultsThe mean follow-up time was 19.54 months. Average preoperative best-corrected visual acuity (BCVA) was 0.73 LogMar (±0.21 SD); while average postoperative BCVA was 0.27 LogMar (±0.23 SD). Fifteen patients underwent anterior pars plana vitrectomy (PPV) while 16 patients did not; moreover, two patients underwent PPV. Six patients had an increase of postoperative intraocular pressure, two patients had postoperative decentration, two patients had postoperative cystoid macular oedema, none of the patients had major complications such as retinal detachment, choroidal detachment, malignant glaucoma, irreversible corneal decompensation and endophthalmitis.ConclusionWe can affirm that our technique may be safe and useful in the case of 3-piece in-the bag or out-of the bag dislocated IOLs and also in the case of in-the-bag single-piece dislocated IOLs.

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Eun Young Choi ◽  
Chul Hee Lee ◽  
Hyun Goo Kang ◽  
Jae Yong Han ◽  
Suk Ho Byeon ◽  
...  

AbstractWe aimed to investigate the efficacy and safety of primary retropupillary iris claw intraocular lens (R-IOL) implantation in patients with complete intraocular lens (IOL) dislocation. In this single-center retrospective case series, we reviewed the medical records of patients who underwent R-IOL implantation surgery with pars plana vitrectomy for the treatment of IOL dislocation between September 2014 and July 2019. The primary outcome was change in visual acuity (VA) up to 24 months postoperatively. The secondary outcomes included changes in intraocular pressure (IOP), refractive errors, and endothelial cell count (ECC) over the same period. Data of 103 eyes (98 patients) were analyzed. The mean uncorrected VA was significantly improved at one month postoperatively (− 0.69 logMAR, P < 0.001), compared to the preoperative value. IOP (− 2.3 mmHg, P = 0.008) and ECC (− 333.4 cells/mm2, P = 0.027) significantly decreased one month post-surgery and remained stable thereafter. Postoperative mean spherical equivalents were similar to the prediction error throughout the follow-up period. IOP elevation (n = 8, 7.8%), cystoid macular edema (n = 4, 3.9%), and dislocation of the R-IOL (n = 10, 9.7%) were managed successfully. Overall, primary R-IOL implantation with pars plana vitrectomy is effective and safe for correcting IOL dislocation due to various causes.


2020 ◽  
Vol 11 (1) ◽  
pp. 48-53
Author(s):  
Abdullah A. Al-Owaid ◽  
Motazz A.  Alarfaj ◽  
Faris A. Alarfaj ◽  
Abdulaziz Awad

The dislocation of a posterior chamber intraocular lens (PC IOL) because of constant eye rubbing is unusual and has never been reported in a child with Leber’s congenital amaurosis (LCA). A 4-year-old full-term girl with an ocular history of LCA presented to the emergency room with a single-piece PC IOL dislocated into the anterior chamber (AC) of the left eye. There was no history of trauma or any other surgical intervention. A specific behavior known as Franceschetti’s oculo-digital sign is a characteristic feature of LCA; this sign consists of repeated pressing, poking, and rubbing of the eyes with knuckles and fingers to stimulate the photoreceptors. This behavior caused the dislocation of the PC IOL into the AC. The dislocated IOL was explanted, and the patient was provided with aphakic glasses.


2016 ◽  
Vol 7 (3) ◽  
pp. 433-439
Author(s):  
Spyridon E. Chalkiadakis ◽  
Efstratios A. Parikakis ◽  
Simon R.J. Taylor

Background: The surgical case of a dropped intraocular lens inside the vitreous cavity constitutes a real challenge for the operating surgeon. Herein, we describe a case series where an alternative optical rehabilitation technique for late intraocular lens-bag complex dislocation has been used. Methods: A modern vitrectomy device was used to remove the capsule with the dropped intraocular lens using sutureless 25-gauge pars plana vitrectomy. To ensure a better aesthetic result, with faster patient recovery and a reduced number of operations, the whole procedure was performed during the same operating session; an iris-claw intraocular lens for aphakia was selected for implantation. The implant was passed behind the constricted iris with the concave surface facing it. The lens was grasped with the manufacturer’s holding forceps and fixed onto the posterior surface of the iris using the special enclavation needles. Results: We have operated 12 eyes in two different clinical centres successfully, with minimal intra- and/or postoperative complications. Conclusion: We believe that this is a viable solution for the visual rehabilitation of patients, who would otherwise need more than one operation for a lens exchange.


2013 ◽  
Vol 5 ◽  
pp. OED.S12672
Author(s):  
Kagmeni Giles ◽  
Moukouri Ernest ◽  
Domngang Christelle ◽  
Nguefack-Tsague Georges ◽  
Cheuteu Raoul ◽  
...  

We assessed the outcomes of the use of anterior chamber foldable lens for unilateral aphakia correction at the University Teaching Hospital of Yaounde. In this retrospective, non-comparative, consecutive case series study, we reviewed the records of patients who underwent an operation for aphakia correction by the means of injection of an angular supported foldable lens between January 2009 and December 2011 in the University Teaching Hospital Yaounde. Student's paired t-test was carried out to compare preoperative and postoperative visual acuity (VA) and intraocular pressure (TOP). P-values less than 0.05 were considered statistically significant. Twenty-one patients were included in the study; twelve were male (57.1%) and nine were female (42.9%). The mean age was 55.38 ± 17.67 years (range 9–75 years). The mean follow-up duration was 5.95 ± 3.14 months (range 2–12 months). The mean logMAR visual acuity was 1.26 ± 0.46 pre-operatively and 0.78 ± 0.57 post-operatively ( P = 0.003). The change in intraocular pressure was not statistically significant. Complications included intraocular hypertension (over 21 mmHg) in 3 patients (14.3%) and macular edema, pupillar ovalization, and retinal detachment in one patient each. The results indicate that injection of an angular support foldable lens in the anterior chamber is a useful technique for the correction of aphakia in eyes without capsular support. More extended follow-up, however, and a larger series of patients are needed to ascertain the effectiveness and safety of this procedure.


2018 ◽  
Vol 16 (2) ◽  
pp. 124-133
Author(s):  
Rosemary Tomy ◽  
Rajkumar Maheshwari ◽  
Ansa Parveen Kunhu Muhammed ◽  
Venkataramana Kalikivayi ◽  
Sajeev Cherian Jacob

Purpose: To assess the indications and visual outcome of eyes undergoing posterior iris fixated intraocular lens (IFIOL) implantation for aphakia, to identify reasons for poor visual outcome, and report occurrence of complications. Methods: In this retrospective case series study, all cases of posterior IFIOL fixation performed over a 30-month period were identified retrospectively. Preoperative and postoperative evaluations comprised objective and subjective refraction, best corrected visual acuity (BCVA), slit lamp biomicroscopy, applanation tonometry, and dilated fundus examination. Results: Fifty-six eyes of 56 patients were analyzed. Mean age was 60.55 ± 17.2 years. The most common indication for IFIOL implantation was surgical aphakia following complicated cataract surgery (n = 33; 58.9%) followed by trauma (n = 10; 17.9%), dropped nucleus/IOL during primary surgery (n = 6; 10.7%), and subluxated/dislocated lens-induced glaucomas (n = 5; 8.9%). BCVA better than or equal to their preoperative BCVA was achieved in 96.43% patients. The surgical aphakia and paediatric/adolescent groups had the best visual results while the dropped nucleus/IOL group and subluxated lens-induced glaucoma groups fared poorly. On the long-term follow-up visit, the most common complication noted was pigment dusting on the corneal endothelium (65.7%). Conclusion: The long-term results suggest that posterior IFIOL implantation is a safe and effective method for correction of aphakia and can be used for a wide range of indications in eyes without adequate capsule support. It may be considered an easier and faster alternative with minimal manipulation to anterior segment structures in paediatric and post-traumatic aphakic eyes.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Yanxiu Sun ◽  
Maximilian Hammer ◽  
Timur M. Yildirim ◽  
Ramin Khoramnia ◽  
Gerd U. Auffarth

AbstractAn Intraocular Lens (IOL) fixated on the iris either anteriorly, as a phakic IOL, or posteriorly, as an aphakic IOL, can influence pupil motility. In this interventional case series study, we evaluated pupil size under different levels of illumination (scotopic = 0.04 lx, low-mesopic = 0.4 lx and high-mesopic = 4 lx) for anterior iris-claw IOL fixation for correcting myopia or hyperopia (IFPH), retropupillary iris-claw IOL fixation to correct aphakia or as treatment for late in-the-bag IOL dislocation/subluxation (IFRP), and capsular-fixation IOL in-the-bag implantation (IB). Pupil size was measured preoperatively for the IFPH- and IB-group as well as 6 months after surgery for all groups. We analyzed a total of 70 eyes: 22 eyes of 11 patients with phakic IOLs, 22 eyes of 20 patients in the IFRP group and 26 eyes of 13 patients in the IB group. Both IFPH and IB showed a smaller postoperative scotopic pupil size, compared with the preoperative values. When compared to postoperative values of IB and IFPH, IFRP showed a significantly smaller postoperative scotopic pupil size (IFPH: 5.89 ± 0.83 mm, IFRP: 4.37 ± 0.83 mm, IB: 5.34 ± 0.98 mm, p < 0.001) while no differences were seen at high-mesopic lighting. Neither of the surgical techniques seems to impair the constriction of the pupil.


2022 ◽  
Author(s):  
Mahmoud Ekram ◽  
Ahmed Mohamed Kamal Elshafei ◽  
Asmaa Anwar Mohamed ◽  
Mohamed Farouk Sayed Othman Abdelkader

Abstract Purpose: To evaluate the anatomical effects of implantable phakic contact lens (IPCL) (Care Group, India) on anterior segment and its visual outcomes .Patients and methods: In a prospective interventional case series study, 60 highly myopic eyes of 32 patients were subjected to IPCL implantation in the Ophthalmology Department of Minia University Hospital, Egypt from January 2019 to June 2021. All patients had complete ophthalmic examination and were followed up for 1 year. Pentacam was used for preoperative and postoperative estimation of anterior chamber depth (ACD), anterior chamber angle (ACA), anterior chamber volume (ACV) and IPCL vault in the 1st, 3rd, and 12th months. Assessment of corneal endothelium was done using specular microscope preoperatively and after 12 months. Preoperative and postoperative refraction and visual acuity were measured. Results: There was a statistically significant decrease in ACD, ACA, and ACV. There was no significant difference between preoperative and postoperative mean intraocular pressure (IOP) by the 12th month (P=0.163). The mean preoperative endothelial cell count (ECD) was significantly reduced from 2929.3±248 cells/mm2 to 2737.9±303 cells/mm2 at the 12th month (P<0.001). with a statistically highly significant improvement of mean Log Mar uncorrected visual acuity (UCVA) from 1.48±0.19 preoperatively to 0.46±0.11 by the end of follow up (P<0.001) with insignificant difference between preoperative best corrected visual acuity (BCVA) and postoperative UCVA (P=0.209). In the 12th month, the mean vault was 240±540 μm. No sight threatening complications occurred.Conclusion: Although IPCL induced anatomical changes, it was safe and effective for correction of high myopia.


2018 ◽  
Vol 28 (4) ◽  
pp. 419-424 ◽  
Author(s):  
Jorge L Alió ◽  
Ana B Plaza-Puche ◽  
Jorge L Alió del Barrio ◽  
Pedro Amat-Peral ◽  
Vicente Ortuño ◽  
...  

Purpose: To evaluate clinical and visual outcomes, quality of near vision, and intraocular optical quality of patients bilaterally implanted with a trifocal PanOptix intraocular lens. Methods: In this prospective consecutive case-series study, 52 eyes of 26 bilateral patients (mean age, 60.2 ± 7.4 years) were implanted with the AcrySof IQ Panoptix intraocular lens. Visual acuity, defocus curve, contrast sensitivity (Pelli-Robson test), near activity visual questionnaire, and internal aberrations with Osiris were evaluated. A prototype light-distortion analyzer was used to quantify the postoperative light-distortion indices. The follow-up was 6 months after surgery. Results: Uncorrected, corrected distance, and uncorrected near visual acuities improved with the surgery (p ≤ 0.02). Distance corrected near visual acuity was 0.13 ± 0.10, 0.13 ± 0.13, and 0.13 ± 0.08 at 1, 3, and 6 months after surgery, respectively (p = 0.82). Distance corrected intermediate visual acuities were 0.09 ± 0.13, 0.13 ± 0.15, and 0.12 ± 0.12 at 1, 3, and 6 months, postoperatively. Binocular contrast sensitivity was 1.86 ± 0.15 Log Units. Defocus curve provided a visual acuity equal or better to 0.30 LogMAR between defocus levels of +0.50 to −3.00 D. The near activity visual questionnaire scores improved significantly with the surgery (p < 0.01). Conclusion: The AcrySof IQ Panoptix intraocular lens is able to restore visual function with an acceptable intermediate and near vision after cataract surgery with good contrast sensitivity and an improvement in the near activity visual questionnaire.


2020 ◽  
Vol 2020 ◽  
pp. 1-7
Author(s):  
Hossam M. Moharram ◽  
Shaaban Abd-Elhamid Mehany Elwan ◽  
Mahmoud M. Nassar ◽  
Mohamed F. Abdelkader

Purpose. One of the most difficult refractory glaucomas is the neovascular type (NVG), and its association with dense cataract adds to this difficulty. This study aimed to provide results of the triple surgical procedure for such conditions. Methods. 12 eyes of 12 patients with NVG and dense cataract were included in this case series study. The mean age of patients was 57.25 ± 5.9 years. The mean preoperative intraocular pressure (IOP) was 47.25 ± 4.04 mmHg with maximum antiglaucoma therapy. The mean best corrected distant visual acuity (BCDVA) in LogMAR was 2.13 ± 0.38. All patients received intravitreal injection of 1.25 mg (0.05 ml) bevacizumab followed by phacoemulsification, pars plana vitrectomy (PPV) including panretinal photocoagulation (PRP), and trabeculectomy with mitomycin C (MMC). Mean IOP and BCDVA changes were the main outcome results of this study. Results. The follow-up period was 2 years. The mean BCDVA was improved to 1.22 ± 0.35, 1.13 ± 0.34, 1.12 ± 0.37, 1.06 ± 0.38, and 1.01 ± 0.37 at 1, 3, 6, 12, and 24 months, respectively, after this procedure. This improvement was statistically significant when compared with preoperative BCDVA (P<0.0001). The mean postoperative IOP was dropped to 20.08 ± 4.1, 17.08 ± 2.1, 17.17 ± 5, 15.75 ± 4.7, and 16.17 ± 6.1 mmHg, respectively. At the last follow-up, the mean IOP was statistically significantly lower than preoperative IOP (P<0.0001) at the previously mentioned time points. The success rate was complete in 90.9% of eyes and qualified in 100% of eyes. Iris and angle neovascularization had regressed significantly in all patients, and no serious complications occurred during the follow-up period. Conclusions. This triple surgery can safely improve patients with NVG and dense cataract regarding BCDVA and IOP control. This trial is registered with NCT04143620.