scholarly journals Treatment of distal clavicle fracture of Neer type II with locking plate in combination with titanium cable under the guide

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Jun Wang ◽  
Jie Guan ◽  
Minbo Liu ◽  
Yongfeng Cui ◽  
Yuhang Zhang

AbstractTo observe and compare the curative effect of a locking plate plus titanium cable under the Guide device and clavicular hook plate in the treatment of Neer type II distal clavicle fractures. A prospective cohort study was conducted to analyse the clinical data of 36 patients with distal clavicle fractures from January 2016 to January 2019. The results were analysed. According to the random number method, the patients were divided into two groups: the titanium cable group (fixed with a titanium cable in combination with a locking plate) and hook plate group (fixed with a clavicular hook plate only). Under the guidance of a special device (for which a patent was obtained), in the titanium cable group, the coracoclavicular ligament was fixed with tension reduction, and then the distal clavicular fracture was fixed with a locking plate. In the hook plate group, the distal clavicle fracture was fixed with a hook plate. The incision length, operation time, bleeding volume and VAS score before, 1 week after and 1 year after the operation were compared between the two groups. The effect of the operation was evaluated by the Constant-Murley score before and 1 year after the operation. X-ray films were taken 2 days, 3 months, half a year and 1 year after the operation to observe the reduction and healing of fractures. At the same time, complications were recorded. The amount of bleeding was the same in the two groups. The operation time in the hook plate group was relatively short, and the difference was statistically significant (P < 0.05). The VAS score in the titanium cable group was significantly lower than that in the hook plate group one year after the operation. The Constant-Murley score in the titanium cable group and hook plate group was significantly higher 1 year after the operation. The number of postoperative complications in the titanium cable group was significantly lower than that in the hook plate group. The treatment of Neer type II distal clavicle fractures with a titanium cable plus a locking plate has a good curative effect, few complications and good postoperative recovery and thus is worth popularizing.

2019 ◽  
Vol 14 (1) ◽  
Author(s):  
Liang Li ◽  
Tian-yan Li ◽  
Peichao Jiang ◽  
Guizhen Lin ◽  
Hongxiao Wu ◽  
...  

Abstract Background The purpose of this meta-analysis was to compare clavicle hook plates versus distal clavicle locking plates for the treatment of Neer type II distal clavicle fractures. Methods PubMed (1996 to January 2019), Embase (1980 to January 2019), Web of Science (1990 to January 2019), the Cochrane Library (January 2019), and the China National Knowledge Infrastructure (January 2019) were systematically searched without language restrictions for literature retrieval. The Constant-Murley shoulder joint function score at 3 and 6 months after the operation and the postoperative complications after the operation (shoulder joint pain, abduction restriction, fracture delay healing, subacromial impingement) were the outcomes. Stata 12.0 was used for the meta-analysis. Results A total of 9 clinical trials involving 446 patients were finally included in this meta-analysis. The results showed that the improvement in the Constant-Murley shoulder joint function score in the distal locking plate group was better than that in the clavicle hook plate group at 3 and 6 months after the operation (P < 0.05). There were fewer cases of shoulder joint pain and restricted shoulder abduction range of motion in the distal locking plate group, and the difference was statistically significant (P < 0.05). There were no statistically significant differences in fracture delay healing and subacromial impingement between the two groups (P > 0.05). Conclusion Compared with the clavicular hook plate, the distal clavicle locking plate for the treatment of Neer type II distal clavicle fractures is associated with better shoulder function recovery and fewer complications related to pain and abduction restriction.


2021 ◽  
Vol 11 (5) ◽  
pp. 1477-1480
Author(s):  
Zhong-Guo Liu ◽  
Yue-Wei Yu ◽  
Huang-Lin Xie ◽  
Qing-Xin Xie

Objective: The aim of this study was to introduce a modified surgical procedure using anatomic locking plate (ALP) fixation and coracoclavicular (CC) stabilisation with multistrand titanium cable (MTC) to repair unstable distal clavicle fractures, and to estimate clinical effects of these people. Materials and methods: Between July 2016 and April 2018, we treated 7 patients with unstable distal clavicle fracture by ALP fixation and CC stabilisation with MTC. After the surgery, we followed up every patient for at least 24 months and analysed their clinical results. Results: The average term required for fracture healing was 9.9 (range, 9–12 weeks) and all cases are successful in fracture healing. The average Constant score was 94.6 points (range, 92–100) at the last follow-up; the modified University of California, Los Angeles (UCLA) shoulder rating scale was 33.4 points (range, 31–35) at the last follow-up. There was no infection, hardware failure and iatrogenic fracture in all the cases. Conclusions: ALP fixation and CC stabilisation with MTC is a really good method for the treatment of unstable distal clavicle fractures. This surgical technique can provide stable fixation for early functional exercise, and prevent extra shoulder joint damage.


2018 ◽  
Vol 21 (4) ◽  
pp. 227-233
Author(s):  
Byungil Yoon ◽  
Jae Yoon Kim ◽  
Jae Sung Lee ◽  
Hyoung Seok Jung

BACKGROUND: The purpose of this study was to compare the radiologic results of patients who underwent surgery with a hook plate and a locking plate in distal clavicle fractures.METHODS: Sixty patients underwent surgical treatment for Neer type IIa, IIb, III, and V distal clavicle fracture. Twenty-eight patients underwent fracture fixation with a hook plate and 32 with a locking plate. Coracoclavicular distance was measured on standard anteroposterior radiographs before and after the surgery, and union was confirmed by radiograph or computed tomography taken at 6 months postoperatively. Other radiologic complications like osteolysis was also checked.RESULTS: Bony union was confirmed in 59 patients out of 60 patients, and 1 patient in the hook plate group showed delayed union. Coracoclavicular distance was decreased more in the hook plate group after surgery (p < 0.01). After 6 weeks of the hook plate removal, the coracoclavicular distance was increased a little compared to before metal removal, but there was no difference compared to the contralateral shoulder. Eleven out of 28 patients (39.3%) showed osteolysis on the acromial undersurface in the hook plate group.CONCLUSIONS: Both the hook plate group and the locking plate group showed satisfactory radiologic results in distal clavicle fractures. Both hook plate and locking plate could be a good treatment option if it is used in proper indication in distal clavicle fracture with acromioclavicular subluxation or dislocation.


2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Fan Zhang ◽  
Qiang Fu ◽  
Yongchuan Li ◽  
Nan Lu ◽  
Aimin Chen ◽  
...  

Abstract Background There is controversy about the optimal strategy treatment of unstable distal clavicle fractures. We explored use of a surgical strategy: combination of a distal clavicle locking plate and a titanium cable. The purpose of this retrospective case series study was to evaluate the clinical outcomes of this new strategy in treating Neer type II distal clavicle fractures. Methods Twenty-one patients with Neer type II distal clavicle fracture were treated with a distal clavicle locking plate and a titanium cable. All patients were followed for at least one year. We retrospectively collected and reviewed follow-up data. The clinical outcomes were assessed for union rate, functional score, and complication rate. Results All patients achieved bony union within 6 months. The average follow-up period was 20.6 months (range12–48 months). The mean Constant score at one-year follow-up was 94.6 ± 3.3 (range 84–98), and the mean UCLA (University of California, Los Angeles) score was 33.3 ± 2.6 (range 27–35). Only one complication (wound infection) was observed during follow-up. Two patients received another operation for implant removal due to local irritation. Conclusions Use of a distal clavicle locking plate in combination with a titanium cable for treatment of Neer type II fractures results in high union rate, a low complication rate, and good shoulder function. This combined surgical strategy can be considered an effective method for treating unstable distal clavicle fractures.


2017 ◽  
Vol 20 (4) ◽  
pp. 230-235
Author(s):  
Woo Dong Nam ◽  
Sung Hoon Moon ◽  
Ki Yong Choi

BACKGROUND: Neer type II distal clavicle fractures have the drawback of coracoclavicular instability and insufficient distal bony fragment, thereby making it difficult to achieve adequate fixation. Although various surgical treatments have been described for Neer type II fracture, the optimal treatment remains controversial. This study reports the clinical results and usefulness of anatomical locking plate with additional K-wire fixation.METHODS: A totally of 21 patients with type II distal clavicle fracture were included in the study. The surgical procedure reduced the fracture temporarily; it included insertion of one or two K-wire from the lateral margin of the distal fragment to the proximal fragment through the fracture site, followed by application and fixation of the locking plate. The bony union and migration of K-wire was evaluated in the follow-up radiography. The coracoclavicular distance and acromioclavicular joint arthrosis were assessed at the final follow-up. The Constant Score (CS) and Korean Shoulder Score (KSS) were evaluated for clinical scoring.RESULTS: Bone union was achieved in all cases. At the final follow-up, coracoclavicular distance of the injured shoulder was increased, as compared to the intact shoulder (p=0.002), with no accompanying clinical symptoms. No K-wire migration was observed. At the final follow-up, K-wire irritation was observed in two cases and acromioclavicular arthrosis in one case, with no other adverse effects. Pain visual analogue scale, CS, and KSS were improved in all cases.CONCLUSIONS: The method of anatomical locking plate with additional K-wire fixation could be useful in achieving beneficial clinical results.


2016 ◽  
Vol 29 (1) ◽  
pp. 55 ◽  
Author(s):  
Kyung Yong Kim ◽  
Joon Yub Kim ◽  
Won Bok Lee ◽  
Myong Gon Jung ◽  
Jeong Hyun Yoo ◽  
...  

2018 ◽  
Vol 46 (11) ◽  
pp. 4678-4683 ◽  
Author(s):  
Jian Xiong ◽  
Jian-Hai Chen ◽  
Yu Dang ◽  
Dian-Ying Zhang ◽  
Zhong-Guo Fu ◽  
...  

Objective This study was performed to compare the clinical efficacy of three internal fixation methods for distal clavicle fractures (Neer type II): clavicular hook plate (Group A), anatomical plate (Group B), and arthroscopic Endobutton (Group C). Methods From 2001 to 2014, 58 patients with Neer type II distal clavicle fractures were treated at our institution. The clinical results were assessed with the visual analog scale (VAS), Constant score, and Simple Shoulder Test (SST) score. Results All patients had anatomic reduction and bone healing at the final follow-up. Groups B and C had considerably less intraoperative blood loss than Group A. The incision was significantly shorter in Group C than in Groups A and B. The mean VAS score was significantly higher in the affected than unaffected shoulder. The Constant and SST scores were significantly higher in the unaffected than affected shoulder. The VAS, Constant, and SST scores of the affected shoulders were not significantly different among the three groups. Conclusions Arthroscopic Endobutton fixation has long-term clinical results similar to those of other surgical protocols for distal clavicle fractures (Neer type II). We recommend this technique because of less blood loss, shorter incision length, and less shoulder irritation than other methods.


Sign in / Sign up

Export Citation Format

Share Document