Putting to work organic sensing molecules in aqueous media: fluorene derivative-containing polymers as sensory materials for the colorimetric sensing of cyanide in water

2010 ◽  
Vol 46 (42) ◽  
pp. 7951 ◽  
Author(s):  
Saúl Vallejos ◽  
Pedro Estévez ◽  
Félix C. García ◽  
Felipe Serna ◽  
José L. de la Peña ◽  
...  
2011 ◽  
Vol 2 (5) ◽  
pp. 1129 ◽  
Author(s):  
Saúl Vallejos ◽  
Hamid El Kaoutit ◽  
Pedro Estévez ◽  
Félix Clemente García ◽  
José Luis de la Peña ◽  
...  

Tetrahedron ◽  
2012 ◽  
Vol 68 (2) ◽  
pp. 690-696 ◽  
Author(s):  
Shigehiro Sumiya ◽  
Takayuki Doi ◽  
Yasuhiro Shiraishi ◽  
Takayuki Hirai

2012 ◽  
Vol 53 (48) ◽  
pp. 6544-6547 ◽  
Author(s):  
Yu Lian Duan ◽  
Yong Gang Shi ◽  
Jian Hua Chen ◽  
Xiang Hua Wu ◽  
Guang Ke Wang ◽  
...  

2009 ◽  
Vol 74 (13) ◽  
pp. 4849-4854 ◽  
Author(s):  
Dae-Sik Kim ◽  
Yun-Mi Chung ◽  
Mieun Jun ◽  
Kyo Han Ahn

2014 ◽  
Vol 43 (35) ◽  
pp. 13299-13306 ◽  
Author(s):  
Samadhan R. Patil ◽  
Jitendra P. Nandre ◽  
Devising Jadhav ◽  
Shilpa Bothra ◽  
S. K. Sahoo ◽  
...  

An imatinib intermediate was developed for the colorimetric sensing of Cu2+ions in aqueous solution.


Nanomaterials ◽  
2021 ◽  
Vol 11 (8) ◽  
pp. 1897
Author(s):  
Abdelaziz Elgamouz ◽  
Chahlaa Nassab ◽  
Alaa Bihi ◽  
Somaya A. I. Mohamad ◽  
Aisha H. S. A. Almusafri ◽  
...  

The β-cyclodextrin shell of synthesized silver nanoparticles (βCD-AgNPs) are found to enhance the detection of hydrogen peroxide in urine when compared to the Horse Radish Peroxidase assay kit. Nanoparticles are confirmed by the UV-Vis absorbance of their localized surface plasmonic resonance (LSPR) at 384 nm. The mean size of the βCD-AgNPs is 53 nm/diameter; XRD analysis shows a face-centered cubic structure. The crystalline structure of type 4H hexagonal nature of the AgNPs with 2.4 nm β-CD coating onto is confirmed using aberration corrected high-resolution transmission electron microscopy (HRTEM). A silver atomic lattice at 2.50 Å and 2.41 Å corresponding to (100) and (101) Miller indices is confirmed using the HRTEM. The scope of βCD-AgNPs to detect hydrogen peroxide (H2O2) in aqueous media and human urine is investigated. The test is optimized by examining the effect of volumes of nanoparticles, the pH of the medium, and the kinetic and temperature effect on H2O2 detection. The βCD-AgNPs test is used as a refined protocol, which demonstrated improved sensitivity towards H2O2 in urine compared to the values obtained by the Horse Radish Assay kit. Direct assessment of H2O2 by the βCD-AgNPs test presented always with a linear response in the nM, μM, and mM ranges with a limit of detection of 1.47 nM and a quantitation limit of 3.76 nM. While a linear response obtained from 1.3 to 37.3 nmoles of H2O2/mole creatinine with a slope of 0.0075 and regression coefficient of 0.9955 when the βCD-AgNPs is used as refined test of creatinine. Values ranging from 34.62 ± 0.23 nmoles of H2O2/mole of creatinine and 54.61 ± 1.04 nmoles of H2O2/mole of creatinine when the matrix is not diluted and between 32.16 ± 0.42 nmoles of H2O2/mole of creatinine and 49.66 ± 0.80 nmoles of H2O2/mole of creatinine when the matrix is twice diluted are found in freshly voided urine of seven apparent healthy men aged between 20 and 40 years old.


Sign in / Sign up

Export Citation Format

Share Document