High-precision Mg-isotope measurements of terrestrial and extraterrestrial material by HR-MC-ICPMS—implications for the relative and absolute Mg-isotope composition of the bulk silicate Earth

2011 ◽  
Vol 26 (3) ◽  
pp. 565 ◽  
Author(s):  
Martin Bizzarro ◽  
Chad Paton ◽  
Kirsten Larsen ◽  
Martin Schiller ◽  
Anne Trinquier ◽  
...  
Author(s):  
Shuyang Li ◽  
Yanli Deng ◽  
Hongtao Zheng ◽  
Xing Liu ◽  
Peidong Tang ◽  
...  

This work provides a new purification procedure for high precision Sb isotopic analysis by using a thiol silica gel column, which is applied to determine Sb isotope composition in natural water samples affected by mining activities.


2017 ◽  
Vol 32 (7) ◽  
pp. 1388-1399 ◽  
Author(s):  
Elsa Yobregat ◽  
Caroline Fitoussi ◽  
Bernard Bourdon

A new protocol using Eichron™ Sr-resin for high-resolution Sr and Ba isotope measurements using thermal ionization mass spectrometry for cosmochemical samples.


2012 ◽  
Vol 5 (3) ◽  
pp. 4003-4040 ◽  
Author(s):  
L. Huang ◽  
A. Chivulescu ◽  
D. Ernst ◽  
W. Zhang ◽  
Y.-S. Lee

Abstract. Maintaining consistent traceability of high precision measurements of CO2 isotopes is critical in being able to observe accurate atmospheric trends of δ13C (CO2). Although a number of laboratories/organizations around the world have been involved in baseline measurements of atmospheric CO2 isotopes for several decades, the reports on their traceability measures are rare. In this paper, a principle and an approach for the traceability maintenance of high precision isotope measurements (δ13C and δ18O) in atmospheric CO2 is described. The uncertainties of the traceability have been estimated based on the history of annual calibrations over the last 10 yr. The overall uncertainties of CO2 isotope measurements for individual ambient samples carried out by our program at Environment Canada are estimated (excluding the uncertainty associated with the sampling). The values are 0.02‰ and 0.05‰ in δ13C and δ18O, respectively, close to the WMO targets for data compatibility. The annual rate of change in δ13C of the primary anchor used in our program (which is the laboratory standard linking ambient measurements back to the primary VPDB scale) is close to zero (−0.0016 ± 0.0012‰ per year) over the period of 10 yr (2001–2011). The average annual decreasing rate of δ13C in air CO2 measurements at Alert over the period from 1999 to 2010 has been confirmed and verified, which is −0.025 ± 0.003‰ per year. The total change of δ13C in the annual mean value during this period is ∼−0.27‰. The concept of "Big Delta" is introduced and its role in maintaining traceability of the isotope measurements is described and discussed extensively. Finally, the challenges and a strategy for maintaining traceability are also discussed and suggested.


2019 ◽  
Vol 44 (1) ◽  
pp. 85-102 ◽  
Author(s):  
Janaína N. Ávila ◽  
Trevor R. Ireland ◽  
Peter Holden ◽  
Peter Lanc ◽  
Andrew Latimore ◽  
...  

2019 ◽  
Vol 259 ◽  
pp. 288-301 ◽  
Author(s):  
Yu-Han Qi ◽  
Fei Wu ◽  
Dmitri A. Ionov ◽  
Igor S. Puchtel ◽  
Richard W. Carlson ◽  
...  

2020 ◽  
Vol 551 ◽  
pp. 119761
Author(s):  
Matthew Jerram ◽  
Pierre Bonnand ◽  
Andrew C. Kerr ◽  
Euan G. Nisbet ◽  
Igor S. Puchtel ◽  
...  

2019 ◽  
Vol 43 (2) ◽  
pp. 291-300 ◽  
Author(s):  
Zhen Zeng ◽  
Xiaohua Li ◽  
Yi Liu ◽  
Fang Huang ◽  
Hui‐Min Yu

Sign in / Sign up

Export Citation Format

Share Document