scholarly journals Synthesis of Pb(ii)-imprinted poly(methacrylic acid) polymeric particles loaded with 1-(2-pyridylazo)-2-naphthol (PAN) for micro-solid phase preconcentration of Pb2+ on-line coupled to flame atomic absorption spectrometry

RSC Advances ◽  
2017 ◽  
Vol 7 (52) ◽  
pp. 33001-33011 ◽  
Author(s):  
Andréia M. Basaglia ◽  
Marcela Z. Corazza ◽  
Mariana G. Segatelli ◽  
César R. T. Tarley

A new ion-selective imprinted polymer based on poly(methacrylic acid) loaded with 1-(2-pyridylazo)-2-naphthol (PAN) (IIP/PAN) has been synthesized, characterized and evaluated for the preconcentration of Pb2+ with on-line determination by flame atomic absorption spectrometry.

Separations ◽  
2019 ◽  
Vol 6 (2) ◽  
pp. 22
Author(s):  
Viktoria Kazantzi ◽  
Aristidis Anthemidis

A novel time-based flow-injection–solid-phase extraction system (FI–SPE) coupled with flame atomic absorption spectrometry (FAAS) for automatic on-line preconcentration and determination of thallium was developed. The efficiency of poly-tetrafluoroethylene (PTFE) turnings packed into a column as sorbent material was investigated for thallium extraction. Total thallium was determined by oxidizing thallium(I) to thallium(III), adding bromine in acidic solution. The formed [TlBr4]− anionic bromo complex was retained onto the PTFE turnings by on-line mixing with sodium diethyl dithiocarbamate (DDTC). The preconcentrated Tl(III)-DDTC complex was then effectively eluted with methyl isobutyl ketone (MIBK) and introduced into the flame atomizer for measurement and quantification. The column proved to be effective, stable, and reproducible, with a long lifetime. The enrichment factor was 105 for 60 s preconcentration time, and the sampling frequency 40 h−1. The detection limit was 1.93 μg L−1, and the relative standard deviation (RSD) was 3.2% at 50.0 μg L−1 concentration. The accuracy of the proposed method was estimated by analyzing certified reference materials and environmental and biological samples.


2007 ◽  
Vol 72 (6) ◽  
pp. 585-590 ◽  
Author(s):  
Morteza Talebi ◽  
Homeyra Safigholi

Arapid, simple, and sensitive procedure based on modified solid phase extraction was developed for the pre-concentration and determination of trace amount of lead in water resources. Lead was reacted with ammonium pyrrolidinedithiocarbamate (APDC) to make a complex. The complex was then collected in a column packed with surfactant-coated alumina. The parameters affecting the collection efficiency and desorption rate of the lead complexes from the column were investigated and optimized. The collection efficiency of the lead complex on the adsorbent was excellent under the optimized conditions. The results obtained from the recovery test showed the capability and reliability of the method for the analysis of trace amounts of lead. The proposed pre-concentration procedure made it possible to apply conventional flame atomic absorption spectrometry (FAAS) for the sensitive determination of trace amounts of lead in water resources. .


Sign in / Sign up

Export Citation Format

Share Document