scholarly journals In situ Rb-Sr dating by collision cell, multicollection inductively-coupled plasma mass-spectrometry with pre-cell mass-filter, (CC-MC-ICPMS/MS).

Author(s):  
Dan Bevan ◽  
Christopher David Coath ◽  
Jamie Lewis ◽  
Johannes B Schwieters ◽  
Nicholas Selwyn Lloyd ◽  
...  

We document the utility for in situ Rb-Sr dating of a one-of-a-kind tribrid mass spectrometer, ‘Proteus’, coupled to a UV laser ablation system. Proteus combines a pre-cell quadrupole mass-filter,collision cell,...

2013 ◽  
Vol 273 ◽  
pp. 614-618
Author(s):  
Ru Ping Ma ◽  
Chuan Qioang Sun

As the main body of the inductively coupled plasma mass spectrometer (ICP-MS), quadrupole mass filter’s performance will largely affect the overall performance of the instrument. Its main performance parameters include the range of mass analysis resolution and the abundance sensitivity. In this article, we have analyzed simulated and then studied its several main performance parameters which affects the instrument.


Author(s):  
Timothy R. Holbrook ◽  
Doriane Gallot-Duval ◽  
Thorsten Reemtsma ◽  
Stephan Wagner

Characterization and investigation into complex nano-fraction samples have traditionally been done using nebulizer single particle inductively coupled plasma mass spectrometry (neb-spICP-MS). Here a method was developed and tested for the...


Author(s):  
Christopher H. Ingles ◽  
John A. Mavrogenes

ABSTRACT Laser ablation-inductively coupled plasma-mass spectrometry was used to traverse hydrothermal vein sphalerite from different ore-forming stages of the Porgera Au-Ag mine, Papua New Guinea. Elements were measured in situ over the growth of crystals to investigate the greatly varying concentrations of cations in sphalerite and their positions in the lattice. Traverse profiles for 16 elements were obtained and aligned to transmitted light images where possible. Each sample contained an array of elements, with many displaying orders of magnitude concentration differences. Results show the simultaneous incorporation of Cu and Sn in sphalerite, as well as Cu and Ag, In and Sn, As and Sb, Fe and Mn, and Cu and Ga. The relation [4Zn2+ ↔ 2Cu+ + Sn2+ + Sn4+] is proposed to explain the 1:1 Cu–Sn correlation. Further relations can be seen, including a Ga “ceiling” or Cu “floor”, where Ga incorporation becomes dependent on Cu concentrations. Furthermore, silver was also observed to correlate with Au, Mn, Ni, Pb, and Bi. Meta-stable solid solutions between pairs such as Cu, Ag; Fe, Mn; As, Sb; and In, Sn are also suggested. Each of these pairs are neighbors on the periodic table of elements, which suggests that simple solid solution can occur, and positive correlations for all four solid solutions were found in one sample alone. While the concept of charge-specific solid solutions in sphalerite has been discussed in the literature with reference to monovalent cations, the results presented herein also indicate solid solutions of higher oxidation states, containing many cations. Furthermore, while cations in charge-specific solid solutions have been proposed to compete for lattice sites in sphalerite, simultaneous in situ coupled concentrations at Porgera suggest otherwise. Cationic substitution equations displaying decimal ratios of each element in solid solution can then provide a novel method to distinguish between solid solution concentrations in different samples. For example, displaying 1:1 ratios of Cu–Ag and Sb–As: [2Zn2+ ↔ (Cu+0.5, Ag+0.5) + (As3+0.5, Sb3+0.5)], or for a 100:1 Fe–Mn ratio: [Zn2+ ↔ (Fe2+0.99, Mn2+0.01)].


Author(s):  
Hai-Ou Gu ◽  
Sun He

This study presents a method for high-precision stable potassium (K) isotope analysis using Multi-Collector Inductively Coupled Plasma Mass Spectrometry (MC-ICPMS) without collision cell in low resolution mode. Cold plasma technique...


Sign in / Sign up

Export Citation Format

Share Document