Speech Intelligibility of Children With Cochlear Implants, Tactile Aids, or Hearing Aids

1993 ◽  
Vol 36 (1) ◽  
pp. 186-203 ◽  
Author(s):  
Mary Joe Osberger ◽  
Monica Maso ◽  
Leslie K. Sam
2021 ◽  
Vol 11 (2) ◽  
pp. 200-206
Author(s):  
Gennaro Auletta ◽  
Annamaria Franzè ◽  
Carla Laria ◽  
Carmine Piccolo ◽  
Carmine Papa ◽  
...  

Background: The aim of this study was to compare, in users of bimodal cochlear implants, the performance obtained using their own hearing aids (adjusted with the standard NAL-NL1 fitting formula) with the performance using the Phonak Naìda Link Ultra Power hearing aid adjusted with both NAL-NL1 and a new bimodal system (Adaptive Phonak Digital Bimodal (APDB)) developed by Advanced Bionics and Phonak Corporations. Methods: Eleven bimodal users (Naìda CI Q70 + contralateral hearing aid) were enrolled in our study. The users’ own hearing aids were replaced with the Phonak Naìda Link Ultra Power and fitted following the new formula. Speech intelligibility was assessed in quiet and noisy conditions, and comparisons were made with the results obtained with the users’ previous hearing aids and with the Naída Link hearing aids fitted with the NAL-NL1 generic prescription formula. Results: Using Phonak Naìda Link Ultra Power hearing aids with the Adaptive Phonak Digital Bimodal fitting formula, performance was significantly better than that with the users’ own rehabilitation systems, especially in challenging hearing situations for all analyzed subjects. Conclusions: Speech intelligibility tests in quiet settings did not reveal a significant difference in performance between the new fitting formula and NAL-NL1 fittings (using the Naída Link hearing aids), whereas the performance difference between the two fittings was very significant in noisy test conditions.


1995 ◽  
Vol 16 (04) ◽  
pp. 370-380 ◽  
Author(s):  
Karen Iler Kirk ◽  
Mary Osberger ◽  
Amy McConkey Robbins ◽  
Allyson Riley ◽  
Susan Todd ◽  
...  

Akustika ◽  
2021 ◽  
pp. 163-167
Author(s):  
Sergei Levin ◽  
Gaziz Tufatulin ◽  
Inna Koroleva ◽  
Viktoriia Vasilyeva ◽  
Elena Levina

The aim was to study amount of attenuation of input signal at the hearing aid (HA) or cochlear implant sound processor (SP) microphone by different protective tools or clothes. Materials and methods. The acoustic measurements were conducted in the soundproof cabin using artificial head with HA/SP and different protective tools, which can influence on microphone function. Probe microphone was integrated in the microphone input of SP and connected with HA verification system. Results. The biggest amount of signal attenuation was observed using water-resistant cases for SP. Changes affect the speech spectrum, therefore using such protective tools can lead to decrease of speech intelligibility. Maximum attenuation was 9.36±0.33 dB at 4000 Hz. Non-hermetic membrane protective cases gave maximum attenuation 7.67±0.18 dB (5000 Hz). Clothes which cover head lead to significant change of signal at microphone up to 9.24±0.16 dB mostly at high-frequencies, which less influences on speech intelligibility. The results confirm that clothes and protective tools for HA of SP show significant attenuation of sounds.


2003 ◽  
Vol 12 (4) ◽  
pp. 440-451 ◽  
Author(s):  
Steven B. Chin ◽  
Patrick L. Tsai ◽  
Sujuan Gao

The objective of this study was to compare the connected speech intelligibility of children who use cochlear implants with that of children who have normal hearing. Previous research has shown that speech intelligibility improves from before cochlear implantation to after implantation and that the speech intelligibility of children who use cochlear implants compares favorably with that of children who use conventional hearing aids. However, no research has yet addressed the question of how the speech intelligibility of children who use cochlear implants compares to that of children with normal hearing. In the current study, archival data on connected speech intelligibility from 51 children with cochlear implants were compared with newly collected data from 47 children with normal hearing. Results showed that for children with cochlear implants, greater intelligibility was associated with both increased chronological age and increased duration of cochlear implant use. Consistent with previous studies, children with normal hearing achieved adult-like or near-adult-like intelligibility around the age of 4 years, but a similar peak in intelligibility was not observed for the children who used cochlear implants. On the whole, children with cochlear implants were significantly less intelligible than children with normal hearing, when controlling both for chronological age and for length of auditory experience. These results have implications for the socialization and education of children with cochlear implants, particularly with respect to on-time placement in mainstream educational environments with age peers.


1994 ◽  
Vol 2 (0) ◽  
pp. 438-443
Author(s):  
Richard S. Tyler ◽  
George B. Haskell ◽  
Aaron J. Parkinson

2017 ◽  
Vol 21 (1) ◽  
pp. 57-60 ◽  
Author(s):  
Mohammad Rezaei ◽  
Maryam Emadi ◽  
Peyman Zamani ◽  
Farhad Farahani ◽  
Gohar Lotfi

1996 ◽  
Vol 5 (1) ◽  
pp. 23-32 ◽  
Author(s):  
Chris Halpin ◽  
Barbara Herrmann ◽  
Margaret Whearty

The family described in this article provides an unusual opportunity to relate findings from genetic, histological, electrophysiological, psychophysical, and rehabilitative investigation. Although the total number evaluated is large (49), the known, living affected population is smaller (14), and these are spread from age 20 to age 59. As a result, the findings described above are those of a large-scale case study. Clearly, more data will be available through longitudinal study of the individuals documented in the course of this investigation but, given the slow nature of the progression in this disease, such studies will be undertaken after an interval of several years. The general picture presented to the audiologist who must rehabilitate these cases is that of a progressive cochlear degeneration that affects only thresholds at first, and then rapidly diminishes speech intelligibility. The expected result is that, after normal language development, the patient may accept hearing aids well, encouraged by the support of the family. Performance and satisfaction with the hearing aids is good, until the onset of the speech intelligibility loss, at which time the patient will encounter serious difficulties and may reject hearing aids as unhelpful. As the histological and electrophysiological results indicate, however, the eighth nerve remains viable, especially in the younger affected members, and success with cochlear implantation may be expected. Audiologic counseling efforts are aided by the presence of role models and support from the other affected members of the family. Speech-language pathology services were not considered important by the members of this family since their speech production developed normally and has remained very good. Self-correction of speech was supported by hearing aids and cochlear implants (Case 5’s speech production was documented in Perkell, Lane, Svirsky, & Webster, 1992). These patients received genetic counseling and, due to the high penetrance of the disease, exhibited serious concerns regarding future generations and the hope of a cure.


1986 ◽  
Vol 51 (4) ◽  
pp. 362-369 ◽  
Author(s):  
Donna M. Risberg ◽  
Robyn M. Cox

A custom in-the-ear (ITE) hearing aid fitting was compared to two over-the-ear (OTE) hearing aid fittings for each of 9 subjects with mild to moderately severe hearing losses. Speech intelligibility via the three instruments was compared using the Speech Intelligibility Rating (SIR) test. The relationship between functional gain and coupler gain was compared for the ITE and the higher rated OTE instruments. The difference in input received at the microphone locations of the two types of hearing aids was measured for 10 different subjects and compared to the functional gain data. It was concluded that (a) for persons with mild to moderately severe hearing losses, appropriately adjusted custom ITE fittings typically yield speech intelligibility that is equal to the better OTE fitting identified in a comparative evaluation; and (b) gain prescriptions for ITE hearing aids should be adjusted to account for the high-frequency emphasis associated with in-the-concha microphone placement.


Author(s):  
Isiaka Ajewale Alimi

Digital hearing aids addresses the issues of noise and speech intelligibility that is associated with the analogue types. One of the main functions of the digital signal processor (DSP) of digital hearing aid systems is noise reduction which can be achieved by speech enhancement algorithms which in turn improve system performance and flexibility. However, studies have shown that the quality of experience (QoE) with some of the current hearing aids is not up to expectation in a noisy environment due to interfering sound, background noise and reverberation. It is also suggested that noise reduction features of the DSP can be further improved accordingly. Recently, we proposed an adaptive spectral subtraction algorithm to enhance the performance of communication systems and address the issue of associated musical noise generated by the conventional spectral subtraction algorithm. The effectiveness of the algorithm has been confirmed by different objective and subjective evaluations. In this study, an adaptive spectral subtraction algorithm is implemented using the noise-estimation algorithm for highly non-stationary noisy environments instead of the voice activity detection (VAD) employed in our previous work due to its effectiveness. Also, signal to residual spectrum ratio (SR) is implemented in order to control the amplification distortion for speech intelligibility improvement. The results show that the proposed scheme gives comparatively better performance and can be easily employed in digital hearing aid system for improving speech quality and intelligibility.


Sign in / Sign up

Export Citation Format

Share Document