Performance Improvement of Digital Hearing Aid Systems

Author(s):  
Isiaka Ajewale Alimi

Digital hearing aids addresses the issues of noise and speech intelligibility that is associated with the analogue types. One of the main functions of the digital signal processor (DSP) of digital hearing aid systems is noise reduction which can be achieved by speech enhancement algorithms which in turn improve system performance and flexibility. However, studies have shown that the quality of experience (QoE) with some of the current hearing aids is not up to expectation in a noisy environment due to interfering sound, background noise and reverberation. It is also suggested that noise reduction features of the DSP can be further improved accordingly. Recently, we proposed an adaptive spectral subtraction algorithm to enhance the performance of communication systems and address the issue of associated musical noise generated by the conventional spectral subtraction algorithm. The effectiveness of the algorithm has been confirmed by different objective and subjective evaluations. In this study, an adaptive spectral subtraction algorithm is implemented using the noise-estimation algorithm for highly non-stationary noisy environments instead of the voice activity detection (VAD) employed in our previous work due to its effectiveness. Also, signal to residual spectrum ratio (SR) is implemented in order to control the amplification distortion for speech intelligibility improvement. The results show that the proposed scheme gives comparatively better performance and can be easily employed in digital hearing aid system for improving speech quality and intelligibility.

2021 ◽  
Author(s):  
Fatos Myftari

This thesis is concerned with noise reduction in hearing aids. Hearing - impaired listeners and hearing - impaired users have great difficulty understanding speech in a noisy background. This problem has motivated the development and the use of noise reduction algorithms to improve the speech intelligibility in hearing aids. In this thesis, two noise reduction algorithms for single channel hearing instruments are presented, evaluated using objective and subjective tests. The first noise reduction algorithm, conventional Spectral Subtraction, is simulated using MATLAB 6.5, R13. The second noise reduction algorithm, Spectral Subtraction in wavelet domanin is introduced as well. This algorithm is implemented off line, and is compared with conventional Spectral Subtraction. A subjective evaluation demonstrates that the second algorithm has additional advantages in speech intelligibility, in poor listening conditions relative to conventional Spectral Subtraction. The subjective testing was performed with normal hearing listeners, at Ryerson University. The objective evaluation shows that the Spectral Subtraction in wavelet domain has improved Signal to Noise Ratio compared to conventional Spectral Subtraction.


2020 ◽  
Vol 31 (01) ◽  
pp. 017-029
Author(s):  
Paul Reinhart ◽  
Pavel Zahorik ◽  
Pamela Souza

AbstractDigital noise reduction (DNR) processing is used in hearing aids to enhance perception in noise by classifying and suppressing the noise acoustics. However, the efficacy of DNR processing is not known under reverberant conditions where the speech-in-noise acoustics are further degraded by reverberation.The purpose of this study was to investigate acoustic and perceptual effects of DNR processing across a range of reverberant conditions for individuals with hearing impairment.This study used an experimental design to investigate the effects of varying reverberation on speech-in-noise processed with DNR.Twenty-six listeners with mild-to-moderate sensorineural hearing impairment participated in the study.Speech stimuli were combined with unmodulated broadband noise at several signal-to-noise ratios (SNRs). A range of reverberant conditions with realistic parameters were simulated, as well as an anechoic control condition without reverberation. Reverberant speech-in-noise signals were processed using a spectral subtraction DNR simulation. Signals were acoustically analyzed using a phase inversion technique to quantify improvement in SNR as a result of DNR processing. Sentence intelligibility and subjective ratings of listening effort, speech naturalness, and background noise comfort were examined with and without DNR processing across the conditions.Improvement in SNR was greatest in the anechoic control condition and decreased as the ratio of direct to reverberant energy decreased. There was no significant effect of DNR processing on speech intelligibility in the anechoic control condition, but there was a significant decrease in speech intelligibility with DNR processing in all of the reverberant conditions. Subjectively, listeners reported greater listening effort and lower speech naturalness with DNR processing in some of the reverberant conditions. Listeners reported higher background noise comfort with DNR processing only in the anechoic control condition.Results suggest that reverberation affects DNR processing using a spectral subtraction algorithm in such a way that decreases the ability of DNR to reduce noise without distorting the speech acoustics. Overall, DNR processing may be most beneficial in environments with little reverberation and that the use of DNR processing in highly reverberant environments may actually produce adverse perceptual effects. Further research is warranted using commercial hearing aids in realistic reverberant environments.


2008 ◽  
Vol 122 (10) ◽  
pp. 1052-1056 ◽  
Author(s):  
M I Trotter ◽  
I Donaldson

AbstractObjectives:(1) To assess the subjective tinnitus perception of patients with audiologically proven hearing loss presenting to a tinnitus clinic, both before and after hearing aid provision; (2) to investigate subjective tinnitus perception in patients with unilateral and bilateral hearing loss; and (3) to assess the impact on tinnitus perception, if any, of a digital hearing aid programme in patients provided with hearing aids.Design:Prospective data collection for patients attending a tinnitus clinic over a 25-year period (1980–2004).Setting:University teaching hospital otolaryngology department.Participants:A total of 2153 consecutive patients attending a consultant-delivered specialist tinnitus clinic.Main outcomes measures:A visual analogue scale was used to assess the degree of tinnitus perception improvement, if any, comparing before versus after unilateral or bilateral aiding (in those with audiometrically proven hearing loss). A further assessment compared the effect of digital hearing aid programme introduction on symptomatic tinnitus perception in patients provided with unilateral or bilateral aids.Results:A total of 1440 patients were given hearing aids (826 unilateral and 614 bilateral). There was little difference in tinnitus perception, comparing overall aiding results in unilaterally or bilaterally aided patients. Overall, 554 (67 per cent) of unilaterally aided patients and 424 (69 per cent) of bilaterally aided patients reported some improvement in their tinnitus perception following aiding. There was a statistically significant improvement in tinnitus perception, comparing analogue aids with digital hearing aids, following introduction of a digital hearing aid programme in 2000, in both unilaterally (p < 0.001) and bilaterally (p < 0.001) aided patients.Conclusions:Provision of hearing aids in patients with audiometrically demonstrable hearing loss can play a very important part in tinnitus control. The additional improvement in tinnitus control observed following introduction of programmable digital aids had a summative effect in the management of these patients.


2011 ◽  
Vol 22 (05) ◽  
pp. 265-273 ◽  
Author(s):  
Francis Kuk ◽  
Heidi Peeters ◽  
Chi Lau ◽  
Petri Korhonen

Background: The maximum power output (MPO) of a hearing aid was typically discussed in the context of avoiding loudness discomfort. However, an MPO that is too low, as in the cases to avoid discomfort for people with a severe loudness tolerance problem and hearing losses that exceed the fitting range of the hearing aids, could negatively affect sound quality and speech intelligibility in noise. Purpose: The current study was designed to demonstrate the degradation in speech intelligibility in noise on the HINT (Hearing in Noise Test) when the MPO of the wearers' hearing aids was lowered by 10 dB from the default. The interactions with noise reduction (NR) algorithms (classic [NR-classic] and Speech Enhancer [NR-SE]) were also examined. Research Design: A single-blinded, factorial repeated-measures design was used to study the effect of noise input level (68 dBC, 75 dBC), MPO setting (default and default-10), and NR algorithm (off, classic, SE) on HINT performance. Study Sample: Eleven adults with a severe sensorineural hearing loss participated. Intervention: Participants were fit with the Widex m4-19 behind-the-ear hearing aids binaurally in the default frequency response and MPO settings. The hearing aids were adjusted to six MPO (default, default-10) by NR (off, classic, SE conditions). Testing was completed within one 2 hr session. Data Collection and Analysis: The RTS (reception threshold for speech) for 50% correct on the HINT was measured in each of the six hearing aid conditions at two input levels (68 and 75 dBC) with speech and noise stimuli presented from the front. Repeated-measures ANOVAs were conducted using SPSS software to examine significant differences. Results: A repeated-measures ANOVA showed that noise level was not significant while NR algorithm and MPO were significant. The interaction between noise level and NR algorithm was also significant. Post hoc analysis with Bonferroni adjustment for the effect of NR algorithm showed that performance with NR-off was significantly poorer than performance with NR-classic and NR-SE (p < 0.05). However, NR-classic and NR-SE were not significantly different from each other (p > 0.05). Conclusions: An MPO that was 10 dB lower than the default could negatively affect the signal-to-noise ratio (SNR) of the listening environment. However, NR could compensate for the degradation in SNR.


2021 ◽  
Author(s):  
Fatos Myftari

This thesis is concerned with noise reduction in hearing aids. Hearing - impaired listeners and hearing - impaired users have great difficulty understanding speech in a noisy background. This problem has motivated the development and the use of noise reduction algorithms to improve the speech intelligibility in hearing aids. In this thesis, two noise reduction algorithms for single channel hearing instruments are presented, evaluated using objective and subjective tests. The first noise reduction algorithm, conventional Spectral Subtraction, is simulated using MATLAB 6.5, R13. The second noise reduction algorithm, Spectral Subtraction in wavelet domanin is introduced as well. This algorithm is implemented off line, and is compared with conventional Spectral Subtraction. A subjective evaluation demonstrates that the second algorithm has additional advantages in speech intelligibility, in poor listening conditions relative to conventional Spectral Subtraction. The subjective testing was performed with normal hearing listeners, at Ryerson University. The objective evaluation shows that the Spectral Subtraction in wavelet domain has improved Signal to Noise Ratio compared to conventional Spectral Subtraction.


2015 ◽  
Vol 719-720 ◽  
pp. 1082-1088
Author(s):  
Feng Jie Xue ◽  
Zhao Yang Guo ◽  
Xin An Wang

Speech processing in hearing aid often operates in noisy environments. So noise reduction algorithm is very important for hearing aid. This paper reviews conventional wiener filter algorithm and points out its remained problems----musical residual noise and low speech intelligibility for low input signal-to-noise ratios (SNR). To solve the problems, the proposed algorithm divides the frequency (0-8000 Hz) into 16 bands in Mel-frequency scale and processes the signal separately to remove musical residual noise. Meanwhile, a new Voice Activity Detector (VAD) applied for digital hearing aid is also presented. Based on the accurate judgment of speech frame, the filter processes the speech frame and non-speech frame in different ways. The method is realized in matlab to test output SNR and PESQ (Perceptual Evaluation of Speech Quality). It is also realized in android app for real-time test. Both of the experimental results demonstrate the advances of the proposed algorithm.


2017 ◽  
Vol 96 (3) ◽  
pp. E33-E38
Author(s):  
Petros V. Vlastarakos ◽  
Alastair I. Cameron ◽  
Thomas P. Nikolopoulos

We conducted a retrospective study to determine the success rate of initial fittings in digital hearing aid (DHA) users. We also addressed the implications of national health systems’ continuing to provide access to these devices. We identified 1,597 consecutively presenting adults who had undergone a first fitting or a new fitting (i.e., an upgrade from an analogue hearing aid in the first or second ear) of a behind-the-ear DHA during the previous year. We further sought to identify all nominal reprogram appointments that had taken place within 6 months after the first or new fitting, we found 460 such appointments (28.8%). Of these, 419 appointments had been for typical reasons other than patient dissatisfaction with the fitting itself—for example, poor hearing, a further hearing loss, an uncomfortably loud hearing aid level, difficulty with speech in noise, an imbalance between bilateral hearing aids, and a faulty or lost hearing aid. Only 41 of the 1,597 first or new fittings (2.6%) were considered unsatisfactory by patients and necessitated a follow-up reprogramming appointment. Overall, DHA fittings were generally successful, as most patients (1,137/1,597 [71.2%]) did not require any follow-up appointment during the study period. Principles of cost-effectiveness demand the maximum practicable efficiency in the utilization of resources to ensure the continuous delivery of high-quality audiologic services through national health systems. This can be achieved by scheduling group appointments to reduce costs and to increase the time allocated to fitting and training patients.


1986 ◽  
Vol 51 (4) ◽  
pp. 362-369 ◽  
Author(s):  
Donna M. Risberg ◽  
Robyn M. Cox

A custom in-the-ear (ITE) hearing aid fitting was compared to two over-the-ear (OTE) hearing aid fittings for each of 9 subjects with mild to moderately severe hearing losses. Speech intelligibility via the three instruments was compared using the Speech Intelligibility Rating (SIR) test. The relationship between functional gain and coupler gain was compared for the ITE and the higher rated OTE instruments. The difference in input received at the microphone locations of the two types of hearing aids was measured for 10 different subjects and compared to the functional gain data. It was concluded that (a) for persons with mild to moderately severe hearing losses, appropriately adjusted custom ITE fittings typically yield speech intelligibility that is equal to the better OTE fitting identified in a comparative evaluation; and (b) gain prescriptions for ITE hearing aids should be adjusted to account for the high-frequency emphasis associated with in-the-concha microphone placement.


2021 ◽  
Vol 11 (2) ◽  
pp. 200-206
Author(s):  
Gennaro Auletta ◽  
Annamaria Franzè ◽  
Carla Laria ◽  
Carmine Piccolo ◽  
Carmine Papa ◽  
...  

Background: The aim of this study was to compare, in users of bimodal cochlear implants, the performance obtained using their own hearing aids (adjusted with the standard NAL-NL1 fitting formula) with the performance using the Phonak Naìda Link Ultra Power hearing aid adjusted with both NAL-NL1 and a new bimodal system (Adaptive Phonak Digital Bimodal (APDB)) developed by Advanced Bionics and Phonak Corporations. Methods: Eleven bimodal users (Naìda CI Q70 + contralateral hearing aid) were enrolled in our study. The users’ own hearing aids were replaced with the Phonak Naìda Link Ultra Power and fitted following the new formula. Speech intelligibility was assessed in quiet and noisy conditions, and comparisons were made with the results obtained with the users’ previous hearing aids and with the Naída Link hearing aids fitted with the NAL-NL1 generic prescription formula. Results: Using Phonak Naìda Link Ultra Power hearing aids with the Adaptive Phonak Digital Bimodal fitting formula, performance was significantly better than that with the users’ own rehabilitation systems, especially in challenging hearing situations for all analyzed subjects. Conclusions: Speech intelligibility tests in quiet settings did not reveal a significant difference in performance between the new fitting formula and NAL-NL1 fittings (using the Naída Link hearing aids), whereas the performance difference between the two fittings was very significant in noisy test conditions.


2021 ◽  
Vol 25 ◽  
pp. 233121652110144
Author(s):  
Ilja Reinten ◽  
Inge De Ronde-Brons ◽  
Rolph Houben ◽  
Wouter Dreschler

Single microphone noise reduction (NR) in hearing aids can provide a subjective benefit even when there is no objective improvement in speech intelligibility. A possible explanation lies in a reduction of listening effort. Previously, we showed that response times (a proxy for listening effort) to an auditory-only dual-task were reduced by NR in normal-hearing (NH) listeners. In this study, we investigate if the results from NH listeners extend to the hearing-impaired (HI), the target group for hearing aids. In addition, we assess the relevance of the outcome measure for studying and understanding listening effort. Twelve HI subjects were asked to sum two digits of a digit triplet in noise. We measured response times to this task, as well as subjective listening effort and speech intelligibility. Stimuli were presented at three signal-to-noise ratios (SNR; –5, 0, +5 dB) and in quiet. Stimuli were processed with ideal or nonideal NR, or unprocessed. The effect of NR on response times in HI listeners was significant only in conditions where speech intelligibility was also affected (–5 dB SNR). This is in contrast to the previous results with NH listeners. There was a significant effect of SNR on response times for HI listeners. The response time measure was reasonably correlated ( R142 = 0.54) to subjective listening effort and showed a sufficient test–retest reliability. This study thus presents an objective, valid, and reliable measure for evaluating an aspect of listening effort of HI listeners.