Accelerated IC test procedure for measuring capacitor ratios using DC extraction techniques

1995 ◽  
Vol 31 (13) ◽  
pp. 1050-1051 ◽  
Author(s):  
T. Manku ◽  
N.R. Swart
1999 ◽  
Vol 15 (2) ◽  
pp. 91-98 ◽  
Author(s):  
Lutz F. Hornke

Summary: Item parameters for several hundreds of items were estimated based on empirical data from several thousands of subjects. The logistic one-parameter (1PL) and two-parameter (2PL) model estimates were evaluated. However, model fit showed that only a subset of items complied sufficiently, so that the remaining ones were assembled in well-fitting item banks. In several simulation studies 5000 simulated responses were generated in accordance with a computerized adaptive test procedure along with person parameters. A general reliability of .80 or a standard error of measurement of .44 was used as a stopping rule to end CAT testing. We also recorded how often each item was used by all simulees. Person-parameter estimates based on CAT correlated higher than .90 with true values simulated. For all 1PL fitting item banks most simulees used more than 20 items but less than 30 items to reach the pre-set level of measurement error. However, testing based on item banks that complied to the 2PL revealed that, on average, only 10 items were sufficient to end testing at the same measurement error level. Both clearly demonstrate the precision and economy of computerized adaptive testing. Empirical evaluations from everyday uses will show whether these trends will hold up in practice. If so, CAT will become possible and reasonable with some 150 well-calibrated 2PL items.


1981 ◽  
Vol 20 (03) ◽  
pp. 174-178 ◽  
Author(s):  
A. I. Barnett ◽  
J. Cynthia ◽  
F. Jane ◽  
Nancy Gutensohn ◽  
B. Davies

A Bayesian model that provides probabilistic information about the spread of malignancy in a Hodgkin’s disease patient has been developed at the Tufts New England Medical Center. In assessing the model’s reliability, it seemed important to use it to make predictions about patients other than those relevant to its construction. The accuracy of these predictions could then be tested statistically. This paper describes such a test, based on 243 Hodgkin’s disease patients of known pathologic stage. The results obtained were supportive of the model, and the test procedure might interest those wishing to determine whether the imperfections that attend any attempt to make probabilistic forecasts have gravely damaged their accuracy.


1974 ◽  
Vol 32 (02/03) ◽  
pp. 483-491
Author(s):  
E. A Loeliger ◽  
M. J Boekhout-Mussert ◽  
L. P van Halem-Visser ◽  
J. D. E Habbema ◽  
H de Jonge

SummaryThe present study concerned the reproducibility of the so-called prothrombin time as assessed with a series of more commonly used modifications of the Quick’s onestage assay procedure, i.e. the British comparative reagent, homemade human brain thromboplastin, Simplastin, Simplastin A, and Thrombotest. All five procedures were tested manually on pooled lyophilized normal and patients’ plasmas. In addition, Simplastin A and Thrombotest were investigated semiautomatically on individual freshly prepared patients’ plasmas. From the results obtained, the following conclusions may be drawn :The reproducibility of results obtained with manual reading on lyophilized plasmas is satisfactory for all five test procedures. For Simplastin, the reproducibility of values in the range of insufficient anticoagulation is relatively low due to the low discrimination power of the test procedure in the near-normal range (so-called low sensitivity of rabbit brain thromboplastins). The reproducibility of Thrombotest excels as a consequence of its particularly easily discerned coagulation endpoint.The reproducibility of Thrombotest, when tested on freshly prepared plasmas using Schnitger’s semiautomatic coagulometer (a fibrinometer-liJce apparatus), is no longer superior to that of Simplastin A.The constant of proportionality between the coagulation times formed with Simplastin A and Thrombotest was estimated at 0.64.Reconstituted Thrombotest is stable for 24 hours when stored at 4° C, whereas reconstituted Simplastin A is not.The Simplastin A method and Thrombotest seem to be equally sensitive to “activation” of blood coagulation upon storage.


2009 ◽  
Vol 5 (1) ◽  
pp. 32
Author(s):  
Melanie Maytin ◽  
Laurence M Epstein ◽  
◽  

Prior to the introduction of successful intravascular countertraction techniques, options for lead extraction were limited and dedicated tools were non-existent. The significant morbidity and mortality associated with these early extraction techniques limited their application to life-threatening situations such as infection and sepsis. The past 30 years have witnessed significant advances in lead extraction technology, resulting in safer and more efficacious techniques and tools. This evolution occurred out of necessity, similar to the pressure of natural selection weeding out the ineffective and highly morbid techniques while fostering the development of safe, successful and more simple methods. Future developments in lead extraction are likely to focus on new tools that will allow us to provide comprehensive device management and the design of new leads conceived to facilitate future extraction. With the development of these new methods and novel tools, the technique of lead extraction will continue to require operators that are well versed in several methods of extraction. Garnering new skills while remembering the lessons of the past will enable extraction technologies to advance without repeating previous mistakes.