scholarly journals Control of active/reactive power and low-voltage ride through for 40 kW three-phase grid-connected single-stage PV system

2017 ◽  
Vol 2017 (1) ◽  
pp. 1655-1659 ◽  
Author(s):  
Mostafa M. Hasaneen ◽  
Mohamed A.L. Badr ◽  
Ahmed M. Atallah
Energies ◽  
2019 ◽  
Vol 12 (15) ◽  
pp. 2899 ◽  
Author(s):  
Alexis B. Rey-Boué ◽  
N. F. Guerrero-Rodríguez ◽  
Johannes Stöckl ◽  
Thomas I. Strasser

This article deals with the vector control in dq axes of a three-phase grid-connected photovoltaic system with single-stage topology and low-voltage-ride-through capability. The photovoltaic generator is built using an array of several series-parallel Suntech PV modules and is modeled as a Lookup Table (two-dimensional; 2-D). The requirements adopted when grid voltage sags occur are based in both the IEC 61400-21 European normative and the allowed amount of reactive power to be delivered according to the Spanish grid code, which avoids the disconnection of the inverter under grid faults by a limitation in the magnitude of the three-phase output inverter currents. For this, the calculation of the positive- and negative-sequences of the grid voltages is made and a conventional three-phase Phase-Locked Loop is used for the inverter-grid synchronization, allowing the control of the active and reactive powers solely with the dq components of the inverter currents. A detailed enhanced flowchart of the control algorithm with low-voltage-ride-through capability is presented and several simulations and experiments using Matlab/SIMULINK and the Controller Hardware-in-the-Loop simulation technique, respectively, are run for several types of one- and three-phase voltage sags in order to validate its behavior.


Energies ◽  
2019 ◽  
Vol 12 (24) ◽  
pp. 4796 ◽  
Author(s):  
Eyad Radwan ◽  
Mutasim Nour ◽  
Emad Awada ◽  
Ali Baniyounes

This paper presents a control scheme for a photovoltaic (PV) system that uses a single-phase grid-connected inverter with low-voltage ride-through (LVRT) capability. In this scheme, two PI regulators are used to adjust the power angle and voltage modulation index of the inverter; therefore, controlling the inverter’s active and reactive output power, respectively. A fuzzy logic controller (FLC) is also implemented to manage the inverter’s operation during the LVRT operation. The FLC adjusts (or de-rates) the inverter’s reference active and reactive power commands based on the grid voltage sag and the power available from the PV system. Therefore, the inverter operation has been divided into two modes: (i) Maximum power point tracking (MPPT) during the normal operating conditions of the grid, and (ii) LVRT support when the grid is operating under faulty conditions. In the LVRT mode, the de-rating of the inverter active output power allows for injection of some reactive power, hence providing voltage support to the grid and enhancing the utilization factor of the inverter’s capacity. The proposed system was modelled and simulated using MATLAB Simulink. The simulation results showed good system performance in response to changes in reference power command, and in adjusting the amount of active and reactive power injected into the grid.


2020 ◽  
Vol 182 ◽  
pp. 02011
Author(s):  
WAN Qian ◽  
Xia Chengjun ◽  
Azeddine Houari ◽  
Zhao Xue ◽  
Xia Chengjun ◽  
...  

Renewable energy sources (RESs) generally connected with electric power system via power electronic interface. This paper presents a reactive power and voltage (Q/V) control strategy of three-phase photovoltaic (PV) system to offering reactive power based on the typical dual-loop control topology. It is worth mentioning that control strategy can support reactive power when a low voltage fault occurs in AC bus without additional compensation device. With the help of the decoupling control, the PV array can generate active power as much as possible in variable external solar radiation conditions. The voltage of PV arrays is adopted as the objective, which on account of the easy availability and controllability of voltage, to control output active power. Besides, accurately modeling process from a PV cell to PV array is described in the beginning to acquire the P-V and V-I characteristics of PV arrays, which promote the designment of Q/V control.


2019 ◽  
Vol 20 (1) ◽  
pp. 140-157
Author(s):  
N Hemalatha ◽  
Seyezhai Ramalingam

A grid-tied, single stage, three phase, PV system provides higher efficiency than a two-stage PV system. This paper presents a three-phase, single stage, grid-connected PV system with MPPT and reactive power injection capability into the grid using modified capacitor assisted extended boost quasi Z-source inverter (MCAEB q-ZSI) as the grid-tied PV inverter. The adaptability of the inverter for irradiance changes and the boost factor control with its shoot-through duty ratio adjustment made it highly recommended for the grid system. The shoot-through control technique like maximum constant boost control with a third harmonic injection enhances the performance of the inverter by reducing the low order ripples and voltage stress. The fuzzy voltage controller is proposed with the capacitor linearization algorithm to regulate the DC-link voltage. The current approach uses a fuzzy controller to control the real and the reactive power injection into the grid. The performance evaluation of the fuzzy and PI grid controller is carried out for the constant irradiance condition and from the investigation, parameters like boost factor (B), the shoot-through duty ratio(Ds), real power (P), reactive power (Q),  power factor and harmonics in the current injection are determined. A laboratory setup of the PV powered grid system is implemented, tested and validated with the simulation results. ABSTRAK: Dalam sistem fotovoltaik (PV) yang bersambung dengan satu peringkat, satu sistem elektronik kuasa yang mempunyai keuntungan dan kecekapan yang tinggi diperlukan untuk menginterupasi dengan utiliti tersebut. Dalam makalah ini, kapasitor yang diubah suai dibantu oleh pemacu kuadratik Z-source yang dilanjutkan (MCAEB q-ZSI) bertindak sebagai unit interfacing antara PV dan grid. Penyesuaian penyongsang untuk perubahan sinaran dan kawalan faktor rangsangan dengan pelarasan nisbah tugas menembak membuatnya sangat disyorkan untuk sistem grid. Teknik kawalan menembak seperti kawalan rangsangan berterusan maksimum dengan suntikan harmonik ketiga meningkatkan prestasi penyongsang dengan mengurangkan aruhan pesanan rendah dan tekanan voltan. Pendekatan semasa menggunakan pengawal kabur untuk mengawal suntikan kuasa sebenar dan reaktif ke grid. Penilaian prestasi pengawal grid fuzzy dan PI dilakukan untuk keadaan iradiasi malar dan dari penyiasatan, parameter seperti faktor rangsangan (B), nisbah tugas menembak (Ds), kuasa nyata (P), kuasa reaktif Q), faktor kuasa dan harmonik dalam suntikan semasa ditentukan.   


2013 ◽  
Vol 2013 ◽  
pp. 1-9 ◽  
Author(s):  
Yongheng Yang ◽  
Frede Blaabjerg

The progressive growing of single-phase photovoltaic (PV) systems makes the Distribution System Operators (DSOs) update or revise the existing grid codes in order to guarantee the availability, quality, and reliability of the electrical system. It is expected that the future PV systems connected to the low-voltage grid will be more active with functionalities of low-voltage ride-through (LVRT) and the grid support capability, which is not the case today. In this paper, the operation principle is demonstrated for a single-phase grid-connected PV system in a low-voltage ride-through operation in order to map future challenges. The system is verified by simulations and experiments. Test results show that the proposed power control method is effective and the single-phase PV inverters connected to low-voltage networks are ready to provide grid support and ride-through voltage fault capability with a satisfactory performance based on the grid requirements for three-phase renewable energy systems.


2021 ◽  
Author(s):  
◽  
Hao Wen

Grid codes is a technical specification which defines the parameters a power system that are connected to the national power systems has to ensure safe, secure and eco-nomic proper functioning of the electric system. One of these requirements is to stay connected to the grid during faults. In such scenarios, the generating unit should remain connected to the grid for a certain period and provide reactive power to support the grid. This is called low voltage ride-through capability. At the early stage, low voltage ride-through requirements were imposed for large scale generators connected to the trans-mission network. However, with the increased penetration of distributed generation, such as PV panels implemented in the distribution network, the low voltage ride-through requirements are also required for distributed generation. With the maturity of PV technology, the cost of PV generation has decreased. Therefore, the total installed capacity of grid-connected PV generation has increased; this has cre-ated new challenges to the low voltage ride-through. Power quality and transient per-formance are the most critical aspects of the grid-connected PV systems under grid faults. PV generation is permitted to switch off from the grid during a fault; however, with the high penetration of the installed PV system, it will degrade the power quality if the same method applied. It is necessary to make sure that the inverter currents remain sinusoidal and within the acceptable limits at the instant of the fault, during and after the fault clearance for different types of faults. Accordingly, this thesis proposes two low voltage ride-through strategies for a 3-phase grid-connected PV system in different reference frames. The presented low voltage ride-through control algorithm in the synchronous reference frame, which fulfils a voltage compensation unit and the reactive power injection block is designed to protect the inverter from overcurrent failure under both symmetrical and asymmetrical faults, reduce the double grid frequency oscillations and provides reac-tive power support by applying a voltage compensation unit. The inverter can also inject sinusoidal current during asymmetrical faults. The method does not require a hard switch from the Maximum Power Point Tracking to a non-Maximum Power Point Tracking algorithm, which ensures a smooth transition. The proposed method in the stationary reference frame provides a fast post-fault recov-ery, which is essential to minimize the fault impacts on the loads and the converter. The method, which consists of a new reference currents calculation block and the voltage compensation unit, maintains the converter current within acceptable limits, produces sinusoidal current even during asymmetrical faults, improves the post-fault recovery performance, and provides independent control for active and reactive powers.


2014 ◽  
Vol 2014 ◽  
pp. 1-13 ◽  
Author(s):  
Faa-Jeng Lin ◽  
Kuang-Chin Lu ◽  
Hsuan-Yu Lee

This study presents a new active and reactive power control scheme for a single-stage three-phase grid-connected photovoltaic (PV) system during grid faults. The presented PV system utilizes a single-stage three-phase current-controlled voltage-source inverter to achieve the maximum power point tracking (MPPT) control of the PV panel with the function of low voltage ride through (LVRT). Moreover, a formula based on positive sequence voltage for evaluating the percentage of voltage sag is derived to determine the ratio of the injected reactive current to satisfy the LVRT regulations. To reduce the risk of overcurrent during LVRT operation, a current limit is predefined for the injection of reactive current. Furthermore, the control of active and reactive power is designed using a two-dimensional recurrent fuzzy cerebellar model articulation neural network (2D-RFCMANN). In addition, the online learning laws of 2D-RFCMANN are derived according to gradient descent method with varied learning-rate coefficients for network parameters to assure the convergence of the tracking error. Finally, some experimental tests are realized to validate the effectiveness of the proposed control scheme.