Degradation of phenol, into mineral compounds, in aqueous solutions using Zero-Valent Iron Powder (ZVIP)

2005 ◽  
Vol 124 ◽  
pp. 81-89 ◽  
Author(s):  
J. Rima ◽  
E. Aoun ◽  
K. Hanna ◽  
Q. X. Li
2007 ◽  
Vol 123 (3) ◽  
pp. 203-208 ◽  
Author(s):  
Hui Zhang ◽  
Ming Jiang ◽  
Zhengqi Wang ◽  
Feng Wu

2021 ◽  
Vol 232 ◽  
pp. 149-164
Author(s):  
Hui Xu ◽  
Minzhang Chen ◽  
Yajuan Zhang ◽  
Pengdong Chen ◽  
Yong Chen

2019 ◽  
Vol 27 (5(137)) ◽  
pp. 150-159
Author(s):  
Simona Kliś ◽  
Maciej Thomas ◽  
Krzysztof Barbusiński ◽  
Klaudiusz Gołombek ◽  
Łukasz Krzemiński ◽  
...  

The article compares the classic Fenton reagent (Fe2+/H2O2) with its modification with zero-valent iron (ZVI/H2O2) to remove azo dye Acid Red 27 from aqueous solutions at a concentration of 100 mg/L. For both methods, the most favorable parameter values ​​were determined at which visual discoloration of the solutions tested was obtained (for Fe2+/H2O2:pH 3.5, H2O2=60 mg/L, Fe2+/H2O2=0.3, t=15 min, and for ZVI/H2O2: pH 3, H2O2=40 mg/L, ZVI=80 mg/L, t=15 min). Under these conditions, the COD value was reduced by 71.5% and 69.2% for the classic Fenton and its modification, respectively. A reduction in toxicity was also obtained for Vibrio fischeri bacteria to below 25% by using the Microtox test. ZVI digestion at acidic pH for 10 minutes allowed to shorten the reaction time by about four times - from 15 to 4 minutes. BET analysis showed that the specific surface area increases with the digestion time, which significantly accelerates the reaction. The visual discoloration of aqueous solutions was obtained, and the final COD values ​​were very small, ranging from 49-53 mg O2/L. According to the Vibrio fischeri toxicity classification test for water samples, all solutions of dyes tested can be considered as non-toxic (toxicity value <25%). In the study presented, results of decreasing the COD value and concentration of the dye in the ZVI/H2O2 method obtained are slightly worse compared to the Fe2+/H2O2 method. However, taking the decolorisation time as a criterion, a four times faster decolorisation time was obtained in the ZVI/H2O2 method, compared to the Fe2+/H2O2 method.


2020 ◽  
Vol 7 (4) ◽  
pp. 045002
Author(s):  
Shang-Qun Li ◽  
Chuang Yu ◽  
Ze-Xiang Wu ◽  
Xiao-Qing Cai ◽  
Fu-Sheng Zha

RSC Advances ◽  
2019 ◽  
Vol 9 (67) ◽  
pp. 39475-39487 ◽  
Author(s):  
Tingyi Liu ◽  
Zhengchao Zhang ◽  
Zhaohui Wang ◽  
Zhong-Liang Wang ◽  
Richard Bush

A zirconium 1,4-dicarboxybenzene metal–organic framework (UiO-66 MOF) was successfully used as a template to enhance the distribution and activity of nanoscale zero-valent iron (NZVI).


2017 ◽  
Vol 243 ◽  
pp. 205-211 ◽  
Author(s):  
Jiwei Liu ◽  
Teza Mwamulima ◽  
Yongmei Wang ◽  
Yi Fang ◽  
Shaoxian Song ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document