scholarly journals Endoscopic ultrasound-guided gastroenterostomy using large-diameter (20 mm) lumen apposing metal stent (LLAMS)

2021 ◽  
Vol 09 (06) ◽  
pp. E895-E900
Author(s):  
Zain A. Sobani ◽  
Swathi Paleti ◽  
Tarun Rustagi

Abstract Background and study aims Endoscopic ultrasound-guided gastroenterostomy (EUS-GE) using a 15-mm lumen apposing metal stent (LAMS) has emerged as a viable alternative to surgical gastrojejunostomy for management of gastric outlet obstruction (GOO). However, given the size of the anastomosis created with a 15-mm LAMS, long-term luminal patency and clinical outcomes may be suboptimal. The aim of this study was to evaluate the technical feasibility, efficacy, and safety of EUS-GE with a large-diameter (20 mm) LAMS (LLAMS). Patients and methods A retrospective analysis of a prospectively maintained database of all patients undergoing EUS-GE with LLAMS between December 1, 2018 and September 30, 2020 was performed. All EUS-GEs were performed using a cautery-enhanced LLAMS. Results Thirty-three patients were referred for endoscopic management of GOO. Two patients were excluded due to a lack of an adequate window for EUS-GE. The remaining 31 patients (93.94 %) (mean age: 61.35 ± 16.52 years; 54.84 % males) underwent EUS-GE using LLAMS for malignant (n = 23) and benign (n = 8) GOO. Technical success was achieved in all patients (100 %) with attempted EUS-GE. Complete clinical success (tolerance of regular diet) was achieved in 93.55 % of patients (n = 29). Two patients (6.45 %) had partial clinical success and died of unrelated causes prior to advancing diet beyond full liquids. Overall mean follow-up was 140.84 ± 160.41 days (median 70, range 4–590). All stents remained patent with no evidence of recurrent GOO symptoms. One patient (3.23 %) developed an asymptomatic clean-based jejunal ulcer on 3-month follow-up endoscopy. Conclusions EUS-GE with LLAMS is a technically feasible, effective and safe option for patients with GOO allowing for tolerability of regular diet. Future prospective, ideally randomized studies comparing long-term outcomes of EUS-GE with 20- and 15-mm LAMS are required.

Endoscopy ◽  
2021 ◽  
Author(s):  
Nam Q. Nguyen ◽  
Christopher M. Hamerski ◽  
Andrew Nett ◽  
Rabindra R. Watson ◽  
Morgan Rigopoulos ◽  
...  

Abstract Background This study evaluated an oroenteric catheter (OEC)-assisted technique to distend the enteric loop for endoscopic ultrasound-guided gastroenterostomy (EUS-GE) in patients with gastric outlet obstruction (GOO). Methods Patient outcomes were reviewed. Proximal enteric loops were filled with water via an OEC (7 Fr or 8 Fr), providing a target for EUS-GE using a lumen-apposing metal stent (15-mm caliber). Clinical success was defined as toleration of a non-liquid diet by Day 3. Results 42 patients (mean age 73.1 [SEM 2.8] years; 23 male) underwent EUS-GE for malignant (n = 37) and benign (n = 5) duodenal strictures. EUS-GE creation was successful in 41/42 (98 %), with mean procedure time of 36 (SEM 3) minutes and no serious complications. Clinical success was achieved in 39/42 (93 %) at 5.7 (SEM 2.6) months’ follow-up. Of 14 patients who died, 13 (93 %) maintained oral intake until death. EUS-GE provided good symptom relief in all 28 surviving patients until follow-up. Conclusions OEC-assisted EUS-GE provided satisfactory relief of GOO symptoms, with high technical success (98 %) and no serious complications.


2020 ◽  
Vol 08 (09) ◽  
pp. E1194-E1201 ◽  
Author(s):  
Janine B. Kastelijn ◽  
Leon M.G. Moons ◽  
Francisco J. Garcia-Alonso ◽  
Manuel Pérez-Miranda ◽  
Viliam Masaryk ◽  
...  

Abstract Background and study aims Endoscopic ultrasound-guided gastroenterostomy (EUS-GE) with a lumen-apposing metal stent (LAMS) is a novel, minimally invasive technique in the palliative treatment of malignant gastric outlet obstruction (GOO). Several studies have demonstrated feasibility and safety of EUS-GE, but evidence on long-term durability is limited. The aim of this study was to evaluate patency of EUS-GE in treatment of malignant GOO. Patients and Methods An international multicenter study was performed in seven centers in four European countries. Patients who underwent EUS-GE with a LAMS between March 2015 and March 2019 for palliative treatment of symptomatic malignant GOO were included retrospectively. Our main outcome was recurrent obstruction due to LAMS dysfunction; other outcomes of interest were technical success, clinical success, adverse events (AEs), and survival. Results A total of 45 patients (mean age 69.9 ± 12.3 years and 48.9 % male) were included. Median duration of follow-up was 59 days (interquartile range [IQR] 41–128). Recurrent obstruction occurred in two patients (6.1 %), after 33 and 283 days of follow-up. Technical success was achieved in 39 patients (86.7 %). Clinical success was achieved in 33 patients (73.3 %). AEs occurred in 12 patients (26.7 %), of which five were fatal. Median overall survival was 57 days (IQR 32–114). Conclusions EUS-GE showed a low rate of recurrent obstruction. The relatively high number of fatal AEs underscores the importance of careful implementation of EUS-GE in clinical practice.


2018 ◽  
Vol 2018 ◽  
pp. 1-6 ◽  
Author(s):  
Daisuke Uchida ◽  
Hironari Kato ◽  
Yosuke Saragai ◽  
Saimon Takada ◽  
Sho Mizukawa ◽  
...  

Background and Aims. Recurrent pancreatitis associated with pancreatic strictures requires treatment with endoscopic retrograde pancreatography (ERP), but it is sometimes technically unsuccessful. Endoscopic ultrasound-guided pancreatic drainage (EUS-PD) was developed as an alternative to a surgical approach after failed ERP; however, the indications for EUS-PD are unclear. In this study, we evaluated the outcomes of EUS-PD and established the indications for EUS-PD. Methods. A total of 15 patients had indications for EUS-PD for recurrent pancreatitis due to pancreatic strictures. There were eight patients with benign pancreatic strictures and seven with malignant pancreatic strictures. The success rate, adverse events, and long-term outcomes were evaluated. Results. The technical success rates of benign and malignant strictures were 75% (6/8) and 100% (7/7), respectively, and clinical success was achieved in 100% (6/6) and 87.5% of cases (6/7), respectively. Rendezvous procedures were performed in two patients with benign strictures. The adverse event (AE) rate was 26.7% (4/15) and included cases of peritonitis, bleeding, and stent migration. Reinterventions were performed in three patients with benign strictures and two with malignant strictures. Conclusions. EUS-PD was an appropriate treatment for not only benign strictures but also malignant strictures with recurrent pancreatitis after failed ERP. However, the AE rate was high, and reinterventions were required in some cases during long-term follow-up. The indications for EUS-PD should be considered carefully, and careful follow-up is needed.


Endoscopy ◽  
2021 ◽  
Author(s):  
Amanda Marino ◽  
Ali Bessissow ◽  
Corey Miller ◽  
David Valenti ◽  
Louis Boucher ◽  
...  

Abstract Introduction We recently developed a double-balloon device, using widely available existing technology, to facilitate endoscopic ultrasound-guided gastroenterostomy (EUS-GE). Our aim is to assess the feasibility of this modified approach to EUS-guided double-balloon-occluded gastroenterostomy bypass (M-EPASS). Methods This was a single-center retrospective study of consecutive patients undergoing M-EPASS from January 2019 to August 2020. The double-balloon device consists of two vascular balloons that optimize the distension of a targeted small-bowel segment for EUS-guided stent insertion. The primary end point was the rate of technical success. Results 11 patients (45 % women; mean [standard deviation (SD)] age 64.9 [8.6]) with malignant gastric outlet obstruction were included. Technical and clinical success (ability to tolerate an oral diet) were achieved in 91 % (10/11) and 80 % (8/10) of patients, respectively. There was one adverse event (9 %) due to stent migration. Two patients (18 %) required re-intervention for stent obstruction secondary to food impaction. The mean (SD) time to a low residue diet was 3.5 (2.4) days. Conclusion M-EPASS appears to facilitate the technique of EUS-GE, potentially enhancing its safety and clinical adoption. Larger studies are needed to validate this innovative approach to gastric outlet obstruction.


Endoscopy ◽  
2020 ◽  
Author(s):  
Gianfranco Donatelli ◽  
Fabrizio Cereatti ◽  
Andrea Spota ◽  
David Danan ◽  
Thierry Tuszynski ◽  
...  

Abstract Background Management of biliary disorders in patients with altered anatomy may be challenging. Endoscopic ultrasound (EUS)-guided gastrointestinal anastomosis using a lumen-apposing metal stent (LAMS) was introduced to allow endoscopic retrograde cholangiography (ERC) in such cases. However, the appropriate stent indwelling time remains uncertain. We report long-term LAMS deployment after duodenojejunal or jejunojejunal anastomosis (EUS-DJA) to allow endoscopic reinterventions in cases of recurrences. Methods 11 consecutive patients underwent EUS-DJA with long-standing LAMS between January 2017 and December 2018. Over a 12-month period, ERC treatment was carried out with multiple endoscopic sessions across the DJA. Results Technical success was 91 % (10/11) for EUS-DJA and 100 % for ERC. Four patients presented stricture recurrence at a mean of 489 days (standard deviation [SD] 31.7) after the end of ERC treatment. A novel ERC across the LAMS anastomosis was feasible in all cases. At a mean of 781 days (SD 253.1), all LAMS remained in place with no evidence of complications. Conclusion Long-term LAMS placement after EUS-DJA may be feasible and safe for direct access to the excluded limb.


2021 ◽  
Vol 29 (4) ◽  
pp. 250
Author(s):  
Nonthalee Pausawasdi ◽  
Manus Rugivarodom ◽  
Pongprueth Rujirachun ◽  
Phunchai Charatchareonwitthaya ◽  
Tanyaporn Chantarojanasiri ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document