IVC-Filter: möglichst kurze Verweilzeiten verbessern Rückholrate

Keyword(s):  
VASA ◽  
2011 ◽  
Vol 40 (2) ◽  
pp. 157-162 ◽  
Author(s):  
Piecuch ◽  
Wiewiora ◽  
Nowowiejska-Wiewiora ◽  
Szkodzinski ◽  
Polonski

The placement of an inferior vena cava (IVC) filter is a therapeutic method for selected patients with deep venous thrombosis and pulmonary embolism. However, insertion and placement of the filter may be associated with certain complications. For instance, retroperitoneal hematoma resulting from perforation of the wall by the filter is such a very rare but serious complication. We report the case of a 64-year-old woman with perforation of the IVC wall and consecutive hematoma caused by the filter who was treated surgically.


VASA ◽  
2021 ◽  
Vol 50 (1) ◽  
pp. 2-10 ◽  
Author(s):  
Xin Li ◽  
Giuseppe D’Amico ◽  
Cristiano Quintini ◽  
Teresa Diago Uso ◽  
Sameer Gadani ◽  
...  

Summary: Intravascular ultrasound (IVUS) has been used extensively in coronary applications. Its use in venous applications has increased as endovascular therapy has increasingly become the mainstay therapy for central venous diseases. IVUS has been used for both diagnostic and therapeutic purposes in managing venous stenotic disease, venous occlusive disease, and IVC filter placement and removal. IVUS has been proven to be effective in providing detailed measurement of the venous anatomy, which aid in determining the appropriate size and the approach for venous stent placement. In IVC filter placement, IVUS can provide detailed measurement and guide IVC filter placement in emergent and critical care settings. It also has certain utility in filter removal. At any rate, to date there are only a few studies examining its impact on patient outcomes. Prospective randomized controlled trials are warranted in the future.


2012 ◽  
Vol 23 (3) ◽  
pp. S119
Author(s):  
R.K. Ryu ◽  
R.J. Lewandowski ◽  
A.C. Eifler ◽  
R. Salem ◽  
R.A. Omary ◽  
...  

2021 ◽  
Vol 5 (2) ◽  
Author(s):  
Masatoshi Narikawa ◽  
Masayoshi Kiyokuni ◽  
Junya Hosoda ◽  
Toshiyuki Ishikawa

Abstract Background Transseptal puncture and pulmonary vein isolation (PVI) in patients with atrial fibrillation (AF) are generally performed via the inferior vena cava (IVC). However, in cases where the IVC is inaccessible, a specific strategy may be needed. Case summary An 86-year-old woman with paroxysmal AF and an IVC filter in situ was referred to our hospital for ablation therapy. An IVC filter for pulmonary embolism and deep venous thrombosis had been implanted 15 years prior, therefore we selected a transoesophageal echocardiography (TOE)-guided transseptal puncture using a superior vena cava (SVC) approach. After the single transseptal puncture, we performed fast anatomical mapping, voltage mapping by multipolar mapping catheter, and then PVI by contact force-guided radiofrequency catheter using a steerable sheath. Following the ablation, bidirectional conduction block between the four pulmonary veins and the left atrium was confirmed by both radiofrequency and mapping catheter. No complications occurred and no recurrence of AF was documented in the 12 months after the procedure. Discussion When performing a transseptal puncture during AF ablation, an SVC approach, via access through the right internal jugular vein, enables the sheath to directly approach the left atrium without angulation and improves operability of the ablation catheter. Combining the use of general anaesthesia, TOE, a steerable sheath, and contact force-guided ablation may contribute to achieving minimally invasive PVI with a single transseptal puncture via an SVC approach.


2021 ◽  
pp. 153857442110225
Author(s):  
Haidong Wang ◽  
Zhenhua Liu ◽  
Xiaofei Zhu ◽  
Jianlong Liu ◽  
Libo Man

Background: Inferior vena cava (IVC) filters are commonly used in China to prevent pulmonary embolisms in patients with deep vein thrombosis. However, IVC filter removal is complicated when the filter has penetrated the IVC wall and endovascular techniques usually fail. The purpose of this study was to evaluate the effectiveness and safety of retroperitoneal laparoscopic-assisted retrieval of wall-penetrating IVC filters after endovascular techniques have failed. Patients and Methods: We retrospectively evaluated a series of 8 patients who underwent retroperitoneal laparoscopic-assisted retrieval of a wall-penetrating IVC filter between December 2017 and November 2019. All patients had experienced at least 1 failure with endovascular retrieval before the study. The filters were slanted and the proximal retrieval hooks penetrated the posterior lateral IVC wall in all patients on computed tomography. Demographic information, operation parameters, and complications were recorded and analyzed. All patients were followed up for at least 12 months. Results: The procedure was successful in all patients. The median surgery time was 53.6 ± 12.7 min and the average blood loss was 45.0 ± 13.5 ml. No serious complication occurred during the patients’ hospitalization, which was an average of 6.4 days. The median follow-up time was 15.1 months, and no patient had deep vein thrombosis recurrence. Conclusions: Retroperitoneal laparoscopic-assisted retrieval is a feasible and effective technique, particularly when proximal retrieval hooks penetrate the posterior lateral wall of the IVC after endovascular techniques have failed. To some extent, the development of this technique at our institution has increased the success rate of filter removal and improved patient satisfaction.


Author(s):  
Francesco Giurazza ◽  
Andrea Contegiacomo ◽  
Marco Calandri ◽  
Cristina Mosconi ◽  
Francesco Modestino ◽  
...  

Author(s):  
Cassius Iyad Ochoa Chaar ◽  
Valentyna Kostiuk ◽  
Navid Gholitabar
Keyword(s):  

2012 ◽  
Vol 23 (3) ◽  
pp. S25
Author(s):  
J. Friese ◽  
B. Leake ◽  
C.J. Fleming ◽  
D.A. Woodrum ◽  
H. Bjarnason ◽  
...  

1993 ◽  
Vol 16 (4) ◽  
pp. 251-253 ◽  
Author(s):  
Timothy C. Goertzen ◽  
Timothy C. McCowan ◽  
Kevin L. Garvin ◽  
Robert P. Lieberman ◽  
Robert F. LeVeen

Sign in / Sign up

Export Citation Format

Share Document