Blinded re-analysis of CT-data with HeartNavigator®: Improved TAVI planning versus TEE and CT alone

2013 ◽  
Vol 61 (S 01) ◽  
Author(s):  
C Schmidtke ◽  
D Richardt ◽  
M Strauch ◽  
J Barkhausen ◽  
HH Sievers ◽  
...  
Keyword(s):  
2007 ◽  
Vol 46 (01) ◽  
pp. 38-42 ◽  
Author(s):  
V. Schulz ◽  
I. Nickel ◽  
A. Nömayr ◽  
A. H. Vija ◽  
C. Hocke ◽  
...  

SummaryThe aim of this study was to determine the clinical relevance of compensating SPECT data for patient specific attenuation by the use of CT data simultaneously acquired with SPECT/CT when analyzing the skeletal uptake of polyphosphonates (DPD). Furthermore, the influence of misregistration between SPECT and CT data on uptake ratios was investigated. Methods: Thirty-six data sets from bone SPECTs performed on a hybrid SPECT/CT system were retrospectively analyzed. Using regions of interest (ROIs), raw counts were determined in the fifth lumbar vertebral body, its facet joints, both anterior iliacal spinae, and of the whole transversal slice. ROI measurements were performed in uncorrected (NAC) and attenuation-corrected (AC) images. Furthermore, the ROI measurements were also performed in AC scans in which SPECT and CT images had been misaligned by 1 cm in one dimension beforehand (ACX, ACY, ACZ). Results: After AC, DPD uptake ratios differed significantly from the NAC values in all regions studied ranging from 32% for the left facet joint to 39% for the vertebral body. AC using misaligned pairs of patient data sets led to a significant change of whole-slice uptake ratios whose differences ranged from 3,5 to 25%. For ACX, the average left-to-right ratio of the facet joints was by 8% and for the superior iliacal spines by 31% lower than the values determined for the matched images (p <0.05). Conclusions: AC significantly affects DPD uptake ratios. Furthermore, misalignment between SPECT and CT may introduce significant errors in quantification, potentially also affecting leftto- right ratios. Therefore, at clinical evaluation of attenuation- corrected scans special attention should be given to possible misalignments between SPECT and CT.


2010 ◽  
pp. 110220121911010
Author(s):  
KATSUHIKO KIMURA ◽  
Yasumasa Fukase ◽  
Michiko Makino ◽  
Chihiro Masaki ◽  
Tetsuji Nakamoto ◽  
...  

2002 ◽  
Vol 9 (4) ◽  
pp. 520-528 ◽  
Author(s):  
Albert Rott ◽  
Thomas Boehm ◽  
Joachim Söldner ◽  
Jürgen R. Reichenbach ◽  
Jürgen Heyne ◽  
...  

Author(s):  
Aylin Akbulut ◽  
Suleyman Kalayci ◽  
Gokhan Koca ◽  
Meliha Korkmaz

Background: Supernumerary kidney is an accessory organ with its own encapsulated parenchyma, blood vessels and ureters, either separated from the normal kidney or connected to it via fibrous tissue and ectopic kidney is a migration abnormality of the kidney. Here, we have evaluated a rare case of the supernumerary and ectopic kidney with DMSA, MAG3 and also CT fusion of the images. Methods: The absolute divided renal function was calculated for each kidney by DMSA. The MAG3 scintigraphy showed no obstruction in the ureteropelvic junction. Furthermore, the renogram curve and Tmax and time to ½ values were assessed. Two months after the conventional scintigraphies, the patient was referred to a CT scan and the fusion of DMSA SPECT and CT data was generated on a workstation. Results: The ectopic supernumerary kidney was functioning very well except a small hypoactive area, visible on DMSA, which was possibly a minimal pelvicalyceal dilatation. However, consequent CT scan did not show any pathology. Conclusion: It is important to evaluate particularly complicated or rare cases with multimodality systems with 3D or fusion techniques for the accurate diagnosis.


2021 ◽  
pp. 028418512110225
Author(s):  
Hideyuki Hayashi ◽  
Kazuto Ashizawa ◽  
Masashi Takahashi ◽  
Katsuya Kato ◽  
Hiroaki Arakawa ◽  
...  

Background Chest radiography (CR) is employed as the evaluation of pneumoconiosis; however, we sometimes encounter cases in which computed tomography (CT) is more effective in detecting subtle pathological changes or cases in which CR yields false-positive results. Purpose To compare CR to CT in the diagnosis of early-stage pneumoconiosis. Material and Methods CR and CT were performed for 132 workers with an occupational history of mining. We excluded 23 cases of arc-welder’s lung. Five readers who were experienced chest radiologists or pulmonologists independently graded the pulmonary small opacities on CR of the remaining 109 cases. We then excluded 37 cases in which the CT data were not sufficient for grading. CT images of the remaining 72 cases were graded by the five readers. We also assessed the degree of pulmonary emphysema in those cases. Results The grade of profusion on CR (CR score) of all five readers was identical in only 5 of 109 cases (4.6%). The CR score coincided with that on CT in 40 of 72 cases (56%). The CT score was higher than that on CR in 13 cases (18%). On the other hand, the CT score was lower than that on CR in 19 cases (26%). The incidence of pulmonary emphysema was significantly higher in patients whose CR score was higher than their CT score. Conclusion CT is more sensitive than CR in the evaluation of early-stage pneumoconiosis. In cases with emphysema, the CR score tends to be higher in comparison to that on CT.


Author(s):  
Darius M. Thiesen ◽  
Dimitris Ntalos ◽  
Alexander Korthaus ◽  
Andreas Petersik ◽  
Karl-Heinz Frosch ◽  
...  

Abstract Introduction For successful intramedullary implant placement at the femur, such as nailing in unstable proximal femur fractures, the use of an implant that at least reaches or exceeds the femoral isthmus and yields sufficient thickness is recommended. A number of complications after intramedullary femoral nailing have been reported, particularly in Asians. To understand the anatomical features of the proximal femur and their ethnic differences, we aimed to accurately calculate the femoral isthmus dimensions and proximal distance of Asians and Caucasians. Methods In total, 1189 Asian and Caucasian segmented 3D CT data sets of femurs were analyzed. The individual femoral isthmus diameter was precisely computed to investigate whether gender, femur length, age, ethnicity or body mass index have an influence on isthmus diameters. Results The mean isthmus diameter of all femurs was 10.71 ± 2.2 mm. A significantly larger diameter was found in Asians when compared to Caucasians (p < 0.001). Age was a strong predictor of the isthmus diameter variability in females (p < 0.001, adjusted r2 = 0.299). With every year of life, the isthmus showed a widening of 0.08 mm in women. A Matched Pair Analysis of 150 female femurs showed a significant difference between isthmus diameter in Asian and Caucasian femurs (p = 0.05). In 50% of the cases the isthmus was found in a range of 2.4 cm between 16.9 and 19.3 cm distal to the tip of the greater trochanter. The female Asian femur differs from Caucasians as it is wider at the isthmus. Conclusions In absolute values, the proximal isthmus distance did not show much variation but is more proximal in Asians. The detailed data presented may be helpful in the development of future implant designs. The length and thickness of future standard implants may be considered based on the findings.


Sign in / Sign up

Export Citation Format

Share Document