Abstract Background and Aims Ultrasound guidance of central venous catheter (CVC) insertion improves the safety and efficacy of its placement, but still it may not ensure correct placement of catheter tip. In our study, we aimed to identify the correct placement of CVC tip and to detect mechanical complications, by visualizing it in real time with the help of sonography and comparing this to the chest X-ray findings. Patients and Methods This was a cross-sectional observational study conducted on 80 patients with American Society of Anesthesiologists grades 1 and 2, in the age group of 18 to 65 years, who required central venous catheterization in intensive care unit. The CVC tip placement was identified with ultrasound and then the finding was compared with postinsertion chest X-ray. Results In only 9 out of the 80 patients (11.3%) malposition was detected on ultrasound and was corrected immediately, whereas in remaining 71 patients (88.8%) no intervention was required. It was observed that all the patients had correct position of CVC tip on postprocedural chest X-ray. Accidental arterial cannulation occurred in two (2.5%) patients in whom right internal jugular vein was cannulated and in two (2.5%) patients who had arrhythmia. Conclusion Ultrasonography (USG) examination can be used as a diagnostic tool method for confirmation of CVC tip and identification of cannulation-related complications. Thus, we can say that USG might obviate the need for post-CVC insertion chest X-ray.

2020 ◽  
Vol 132 (4) ◽  
pp. 781-794 ◽  
Author(s):  
Jasper M. Smit ◽  
Mark E. Haaksma ◽  
Endry H. T. Lim ◽  
Thei S. Steenvoorden ◽  
Michiel J. Blans ◽  
...  

Abstract Background Mechanical complications arising after central venous catheter placement are mostly malposition or pneumothorax. To date, to confirm correct position and detect pneumothorax, chest x-ray film has been the reference standard, while ultrasound might be an accurate alternative. The aim of this study was to evaluate diagnostic accuracy of ultrasound to detect central venous catheter malposition and pneumothorax. Methods This was a prospective, multicenter, diagnostic accuracy study conducted at the intensive care unit and postanesthesia care unit. Adult patients who underwent central venous catheterization of the internal jugular vein or subclavian vein were included. Index test consisted of venous, cardiac, and lung ultrasound. Standard reference test was chest x-ray film. Primary outcome was diagnostic accuracy of ultrasound to detect malposition and pneumothorax; for malposition, sensitivity, specificity, and other accuracy parameters were estimated. For pneumothorax, because chest x-ray film is an inaccurate reference standard to diagnose it, agreement and Cohen’s κ-coefficient were determined. Secondary outcomes were accuracy of ultrasound to detect clinically relevant complications and feasibility of ultrasound. Results In total, 758 central venous catheterizations were included. Malposition occurred in 23 (3.3%) out of 688 cases included in the analysis. Ultrasound sensitivity was 0.70 (95% CI, 0.49 to 0.86) and specificity 0.99 (95% CI, 0.98 to 1.00). Pneumothorax occurred in 5 (0.7%) to 11 (1.5%) out of 756 cases according to chest x-ray film and ultrasound, respectively. In 748 out of 756 cases (98.9%), there was agreement between ultrasound and chest x-ray film with a Cohen’s κ-coefficient of 0.50 (95% CI, 0.19 to 0.80). Conclusions This multicenter study shows that the complication rate of central venous catheterization is low and that ultrasound produces a moderate sensitivity and high specificity to detect malposition. There is moderate agreement with chest x-ray film for pneumothorax. In conclusion, ultrasound is an accurate diagnostic modality to detect malposition and pneumothorax. Editor’s Perspective What We Already Know about This Topic What This Article Tells Us That Is New


2021 ◽  
Vol 10 (4) ◽  
pp. e001222
Author(s):  
Enyo A Ablordeppey ◽  
Byron Powell ◽  
Virginia McKay ◽  
Shannon Keating ◽  
Aimee James ◽  
...  

IntroductionAvoiding low value medical practices is an important focus in current healthcare utilisation. Despite advantages of point-of-care ultrasound (POCUS) over chest X-ray including improved workflow and timeliness of results, POCUS-guided central venous catheter (CVC) position confirmation has slow rate of adoption. This demonstrates a gap that is ripe for the development of an intervention.MethodsThe intervention is a deimplementation programme called DRAUP (deimplementation of routine chest radiographs after adoption of ultrasound-guided insertion and confirmation of central venous catheter protocol) that will be created to address one unnecessary imaging modality in the acute care environment. We propose a three-phase approach to changing low-value practices. In phase 1, we will be guided by the Consolidated Framework for Implementation Research framework to explore barriers and facilitators of POCUS for CVC confirmation in a single centre, large tertiary, academic hospital via focus groups. The qualitative methods will inform the development and adaptation of strategies that address identified determinants of change. In phase 2, the multifaceted strategies will be conceptualised using Morgan’s framework for understanding and reducing medical overuse. In phase 3, we will locally implement these strategies and assess them using Proctor’s outcomes (adoption, deadoption, fidelity and penetration) in an observational study to demonstrate proof of concept, gaining valuable insights on the programme. Secondary outcomes will include POCUS-guided CVC confirmation efficacy measured by time and effectiveness measured by sensitivity and specificity of POCUS confirmation after CVC insertion.With limited data available to inform interventions that use concurrent implementation and deimplementation strategies to substitute chest X-ray for POCUS using the DRAUP programme, we propose that this primary implementation and secondary effectiveness pilot study will provide novel data that will expand the knowledge of implementation approaches to replacing low value or unnecessary care in acute care environments.Ethics and disseminationApproval of the study by the Human Research Protection Office has been obtained. This work will be disseminated by publication of peer-reviewed manuscripts, presentation in abstract form at scientific meetings and data sharing with other investigators through academically established means.Trial registration numberClinicalTrials.gov Identifier, NCT04324762, registered on 27 March 2020.


2020 ◽  

Study objective: Central venous catheterization is an essential component of intensive care of critically ill patients, and proper positioning of the catheter is essential to prevent position-related complications. This study was conducted by using digital tape measurement to objectively assess clinician preferences for central venous catheter positioning based on specific position levels and landmarks on post-procedural chest radiographs. Design: A cross-sectional study using electronic questionnaire survey. Setting: Single academic teaching hospital participated in this study. Participants: The study enrolled 276 physicians from multiple clinical disciplines. Interventions: None. Measurements: A seven-level reference system labeled on a sample chest radiograph was used to identify the acceptable lower and upper limits and landmarks used to determine the optimal central venous catheter tip position as well as the pattern of clinical practices based on the specialty and level of experience of participants. Main results: Among the 276 respondents, the ratio of cumulative acceptance for the lower and upper catheter tip limit was 62% and 66.3% within a 4-cm range below or above the carina, respectively. Intensive care unit (ICU) physicians showed a greater tendency to choose a catheter tip 4 cm below and 6 cm above the carina (p = 0.004 and 0.002, respectively) as did experienced physicians (p = 0.007 and < 0.001, respectively). The commonest reason for catheter tip withdrawal was arrhythmia (50% of cases). Physicians in the ICU and experienced physicians were more concerned about the risk of cardiac perforation than other respondents (p < 0.001 and < 0.001, respectively). The carina was the most commonly used landmark in 71.7% of all physicians, although 50% of radiologists also used other landmarks. Conclusions: The acceptable limit of the catheter tip is 4 cm above and below the carina (-4 to +4), as determined on chest radiography, without a need for tip adjustment.


2014 ◽  
Vol 32 (1) ◽  
pp. 78-81 ◽  
Author(s):  
Francesca Cortellaro ◽  
Luca Mellace ◽  
Stefano Paglia ◽  
Giorgio Costantino ◽  
Sara Sher ◽  
...  

2012 ◽  
Vol 14 (1) ◽  
pp. 97-98 ◽  
Author(s):  
Simonetta Nataloni ◽  
Andrea Carsetti ◽  
Vincenzo Gabbanelli ◽  
Abele Donati ◽  
Erica Adrario ◽  
...  

Critical Care ◽  
2014 ◽  
Vol 18 (Suppl 1) ◽  
pp. P129 ◽  
Author(s):  
MS Vallecoccia ◽  
F Cavallaro ◽  
M Biancone ◽  
D Settanni ◽  
C Marano ◽  
...  

2006 ◽  
Vol 42 (3) ◽  
pp. 154-155
Author(s):  
M.A. Hernández-Hernández ◽  
B. Suberviola-Cañas ◽  
M.M. Cabello-Nájera