Single Incision, Dual Window Approach for a Comminuted Distal Radius Fracture

Author(s):  
Arianna Gianakos ◽  
Priya Patel ◽  
Christian M. Athens ◽  
John T. Capo

Abstract Introduction Complex distal radius fractures often involve a fragment of the volar-ulnar articular surface and the radial styloid. The volar ulnar corner of the distal radius is an important constraint to volar translation of the carpus and thus requires stable fixation to prevent wrist displacement. The traditional volar Henry approach often requires undue tension on the median nerve while retracting for access to the ulnar aspect of the radius. To protect the median nerve from iatrogenic injury and to improve exposure of the surgical site, we propose a single incision, dual window approach to the distal radius for complex bi-columnar fractures. Methods This technique combines the trans-Flexor Carpi Radialis (FCR) approach with a subcutaneous dissection to the ulnar aspect of the wrist. This window utilizes the interval between the ulnar neurovascular bundle and the carpal tunnel contents. Results This technique allows the surgeon to work through either window and thus visualize and directly fixate the various fracture fragments. We have treated complex articular distal radius fractures associated with ulnar communition with this novel technique and it has provided direct reduction with improved fragment access. The surgical technique, a case presentation and results are detailed in this report. Conclusion This case report has demonstrated that complex bi-columnar fractures of the distal radius can be effectively approached and fixated with a single incision dual window approach.

2012 ◽  
Vol 37 (8) ◽  
pp. 765-771 ◽  
Author(s):  
A. S. Gavaskar ◽  
S. Muthukumar ◽  
N. Chowdary

The goal was to evaluate the efficacy of 2.4 mm column-specific plating for intra-articular distal radius fractures. In total, 105 patients with AO type C distal radius fractures were operated on using the locking distal radius system, Synthes. Follow-up assessments including clinical (wrist and forearm range of motion, grip strength), radiological (articular step, radial length and inclination, volar tilt, and ulnar variance), and functional scores (Disabilities of the Arm, Shoulder, and Hand; Patient Rated Wrist Evaluation) were made at regular intervals until 1 year. Union was obtained in all patients. Articular surface was anatomically reconstructed in 74 patients (70.5%). Clinical and functional evaluation showed significant continuous improvements over the first year. C1 fractures had a better chance of anatomical reduction compared with C2 and C3 fractures. Fracture type, quality of reduction, and presence of degenerative changes did not show a significant effect on functional outcome scores. Column-specific fixation of the distal radius can achieve satisfactory results in complex intra-articular fractures.


2017 ◽  
Vol 43 (2) ◽  
pp. 142-147 ◽  
Author(s):  
Daniel Martinez-Mendez ◽  
Alejandro Lizaur-Utrilla ◽  
Joaquin de-Juan-Herrero

We compared outcomes in elderly patients with intra-articular distal radius fractures treated by closed reduction and plaster immobilization or open reduction and internal fixation with a volar plate. Ninety-seven patients older than 60 years were randomly allocated to conservative (47 patients) or surgical (50 patients) treatment. Over a 2-year period, we assessed patient-rated wrist evaluation score, DASH (disability arm, shoulder and hand) questionnaire, pain, wrist range of motion, grip strength, and radiological parameters. The functional outcomes and quality of life were significantly better after volar plating fixation compared with conservative treatment. We found that restoration of the articular surface, radial inclination, and ulnar variance affected the outcomes, but the articular step-off did not. Twenty-five per cent of the patients with conservative treatment had secondary loss of reduction. We conclude that surgical plating leads to better outcomes than conservative treatment for elderly patients with intra-articular distal radius fractures. Level of evidence: I


Author(s):  
Ha Sung Park ◽  
Shin Woo Choi ◽  
Joo-Yul Bae

Purpose: During volar plate fixation of distal radius fractures, we have encountered patients with an anomalous course of the palmar cutaneous branch (PCB) of the median nerve within the sheath of the flexor carpi radialis (FCR) tendon. The purpose of this study was to assess the frequency and location of variations of the PCB within the sheath of the FCR tendon.Methods: This retrospective study enrolled 83 patients who underwent volar locking plate fixations through a modified Henry approach for distal radius fractures from July 2018 to April 2020. When we encountered an anomalous PCB within the sheath of the FCR tendon, we documented the specific finding and location where the PCB entered the sheath of the FCR tendon.Results: There were nine patients (10.8%) who had an anomalous course of PCB penetrating the sheath of the FCR tendon. The average entering point of PCB into the sheath of the FCR tendon was 3.07 cm from the distal wrist crease (range, 2.5–3.6 cm).Conclusion: An anomalous course of the PCB entering the sheath of the FCR tendon was observed at a high frequency (10.8%). Care must be taken not to injure the PCB during a dissecting of the FCR sheath during a modified Henry approach for a distal radius fracture.


2020 ◽  
Vol 15 (1) ◽  
Author(s):  
Lingde Kong ◽  
Meng Fu ◽  
Jian Lu ◽  
Yanqing Zhou ◽  
Zuzhuo Zhang ◽  
...  

Abstract Background The objective of this study was to predict the function of the forearm rotation on the basis of the articular surface of the sigmoid notch from three-dimensional reconstruction images. Methods We retrospectively reviewed patients who underwent volar plate fixation for intra-articular distal radius fractures (DRFs) in our institution between January 2017 and July 2019. The 3D image of the sigmoid notch on the fractured distal radius was reconstructed and looked up from the ulnar view to determine the existence of gaps or steps. Patients with or without gaps/steps on the sigmoid notch were included in the case group or control group, respectively. The patients’ basic data and postoperative data were collected and compared. Results A total of 81 patients were included. There were 33 patients in the case group, and 48 patients in the control group. There was no significant difference between the two groups at baseline. The total range of motion (ROM) of rotation in the case group and control group was 130.3 ± 6.2° and 145.3 ± 6.7°, respectively (P < 0.001). The percentage of rotation ROM of contralateral limb in the case group and control group was 72.3 ± 3.1% and 80.7 ± 3.6%, respectively (P < 0.001). VAS during forearm rotation was 2.1 ± 0.7 in the case group, which is significantly higher than that in the control group (1.5 ± 0.5, P < 0.001). Conclusion This study proposed a new method to assess the articular surface of the sigmoid notch which is based on 3D reconstruction images. With the assistance of this method, we found that gaps or steps on the sigmoid notch not only limit forearm pronation rotation and supination rotation, but also cause apparent wrist pain during forearm rotation movement and poor wrist ability.


2017 ◽  
Vol 2017 ◽  
pp. 1-5
Author(s):  
Hiroyuki Obata ◽  
Tomonori Baba ◽  
Kentaro Futamura ◽  
Osamu Obayashi ◽  
Atsuhiko Mogami ◽  
...  

Recent reports suggest the presence of a rare fracture type for which reduction and fixation cannot be achieved with volar locking plate (VLP). In particular, it is difficult to achieve reduction and fixation with volar lunate facet (VLF) fragments present on the volar ulnar aspect of the lunate facet, because of the anatomical structure and biomechanics in this region. Herein, we report two challenging cases of difficulty in fixation of the VLF fragment in distal radius fracture. For this fracture type, it is most important to identify the volar ulnar bone fragment before surgery; it may also be necessary to optimize distal placement of the VLP via a dual-window approach and to apply additional fixations, such as a small plate, anchor, and/or external fixation.


Hand Surgery ◽  
2007 ◽  
Vol 12 (03) ◽  
pp. 199-204 ◽  
Author(s):  
Mark Henry ◽  
Christopher Stutz

Loss of median nerve function or a neuropathic pain syndrome may occur in around 20% of distal radius fractures if post-traumatic oedema in the carpal canal generates excessive pressure on the median nerve. No method currently exists to reliably distinguish which patients may benefit from a concomitant carpal tunnel release. This case series details the results of following a prospective plan designed to minimise median nerve related complications associated with distal radius fractures by measuring Semmes-Weinstein monofilament scores in 374 radius fracture patients who underwent surgical stabilisation. One hundred and sixty-nine patients with the clinical symptoms of median nerve compression, a decrement in monofilament score of grade 1 (out of 5) compared to the contralateral side or at least 4.31 g underwent concomitant carpal tunnel release. The remaining 205 patients did not have carpal tunnel release. There were no cases of neuropathic pain or loss of median nerve function.


1993 ◽  
Vol 42 (4) ◽  
pp. 1608-1614
Author(s):  
Makoto Tamai ◽  
Hikaru Tashima ◽  
Yoshifumi Shimomura ◽  
Ichiro Itonaga ◽  
Takashi Fukumoto ◽  
...  

Sign in / Sign up

Export Citation Format