Zentraler aortaler Blutdruck: Bedeutender Parameter für Diagnostik und Therapie

2017 ◽  
Vol 142 (19) ◽  
pp. 1430-1436 ◽  
Author(s):  
Martin Middeke

AbstractIn recent years great emphasis has been placed on the role of central aortic blood pressure as measured non invasively using pulse wave analysis in pathophysiology of cardiovascular diseases and clinical aspects of hypertension. The difference of blood pressure between the central aorta and the brachial artery (amplification) is not constant but varies according to physiological, pathological and pharmacological mechanisms. Central aortic blood pressure is more strongly related to cardiovascular organ damages than does brachial pressure. Several antihypertensive drugs have different effects on aortic blood pressure as compared with brachial pressure. Central aortic blood pressure emerges superior to brachial pressure as target blood pressure in antihypertensive treatment.

2018 ◽  
Vol 31 (12) ◽  
pp. 1286-1292 ◽  
Author(s):  
Michelle M Harbin ◽  
Neil E Hultgren ◽  
Aaron S Kelly ◽  
Donald R Dengel ◽  
Nicholas G Evanoff ◽  
...  

2020 ◽  
Vol 6 (3) ◽  
pp. 147-154
Author(s):  
Isabella Tan ◽  
Mark Butlin ◽  
Fatemeh Shirbani ◽  
James R. Cox ◽  
Karen Peebles ◽  
...  

2018 ◽  
Vol 41 (7) ◽  
pp. 378-384 ◽  
Author(s):  
Alper Erdan ◽  
Abdullah Ozkok ◽  
Nadir Alpay ◽  
Vakur Akkaya ◽  
Alaattin Yildiz

Background: Arterial stiffness is a strong predictor of mortality in hemodialysis patients. In this study, we aimed to investigate possible relations of arterial stiffness with volume status determined by bioimpedance analysis and aortic blood pressure parameters. Also, effects of a single hemodialysis session on these parameters were studied. Methods: A total of 75 hemodialysis patients (M/F: 43/32; mean age: 53 ± 17) were enrolled. Carotid-femoral pulse wave velocity, augmentation index, and aortic pulse pressure were measured by applanation tonometry before and after hemodialysis. Extracellular fluid and total body fluid volumes were determined by bioimpedance analysis. Results: Carotid-femoral pulse wave velocity (9.30 ± 3.30 vs 7.59 ± 2.66 m/s, p < 0.001), augmentation index (24.52 ± 9.42 vs 20.28 ± 10.19, p < 0.001), and aortic pulse pressure (38 ± 14 vs 29 ± 8 mmHg, p < 0.001) significantly decreased after hemodialysis. Pre-dialysis carotid-femoral pulse wave velocity was associated with age (r2 = 0.15, p = 0.01), total cholesterol (r2 = 0.06, p = 0.02), peripheral mean blood pressure (r2 = 0.10, p = 0.005), aortic-mean blood pressure (r2 = 0.06, p = 0.02), aortic pulse pressure (r2 = 0.14, p = 0.001), and extracellular fluid/total body fluid (r2 = 0.30, p < 0.0001). Pre-dialysis augmentation index was associated with total cholesterol (r2 = 0.06, p = 0,02), aortic-mean blood pressure (r2 = 0.16, p < 0.001), and aortic pulse pressure (r2 = 0.22, p < 0.001). Δcarotid-femoral pulse wave velocity was associated with Δaortic-mean blood pressure (r2 = 0.06, p = 0.02) and inversely correlated with baseline carotid-femoral pulse wave velocity (r2 = 0.29, p < 0.001). Pre-dialysis Δaugmentation index was significantly associated with Δaortic-mean blood pressure (r2 = 0.09, p = 0.009) and Δaortic pulse pressure (r2 = 0.06, p = 0.03) and inversely associated with baseline augmentation index (r2 = 0.14, p = 0.001). In multiple linear regression analysis (adjusted R2 = 0.46, p < 0.001) to determine the factors predicting Log carotid-femoral pulse wave velocity, extracellular fluid/total body fluid and peripheral mean blood pressure significantly predicted Log carotid-femoral pulse wave velocity (p = 0.001 and p = 0.006, respectively). Conclusion: Carotid-femoral pulse wave velocity, augmentation index, and aortic pulse pressure significantly decreased after hemodialysis. Arterial stiffness was associated with both peripheral and aortic blood pressure. Furthermore, reduction in arterial stiffness parameters was related to reduction in aortic blood pressure. Pre-dialysis carotid-femoral pulse wave velocity was associated with volume status determined by bioimpedance analysis. Volume control may improve not only the aortic blood pressure measurements but also arterial stiffness in hemodialysis patients.


Sign in / Sign up

Export Citation Format

Share Document