scholarly journals A hybrid filter to mitigate harmonics caused by nonlinear load and resonance caused by power factor correction capacitor

2017 ◽  
Author(s):  
N. F. Adan ◽  
D. M. Soomro

This paper presents multifunctional operation capability of three level cascade H bridge inverter for grid connected solar pv application. The solar panel and inverter are modelled for unbalance and nonlinear loads with three control techniques (pq,dq,cpt) and its performance is simulated in the MATLAB environment using SIMULINK and Sim Power System (SPS) toolboxes. The performance of inverter is evaluated for harmonics elimination, power factor correction apart from active and reactive power support to grid and nonlinear load .Performance of three level H bridge inverter is evaluated for both PV mode and STATCOM mode using three control techniques for distribution grid.


Author(s):  
Fernando Nogueira de Lima ◽  
Alex Henrique Braga ◽  
Antonio de Padua Finazzi ◽  
Bismarck Castillo Carvalho ◽  
Etiane Oliveira Ponciano de Carvalho

Author(s):  
Deepthi Janyavula ◽  
Satyendra Nath Saxena

<span>The proposed scheme has considered a three-phase four-wire system, which experienced sag and swell in source voltage for a certain period while feeding an unbalanced and variable non-linear load. The load has unequal resistive and reactive elements in the three phases, forming the unbalanced component. A three-phase silicon controlled rectifier converter with adjustable firing angle connected to the load has formed the variable non-linear component. This has been considered, so as to simulate the unbalanced and variable non-linear  nature of loads in real-time power system. The trends in the total harmonic distortion variation were obtained for the proposed system under power factor correction and voltage regulation mode operation when the load-side converter firing angles of 30°, 60° and 90° were considered using MATLAB/SIMULINK software. Three pulse-width-modulation methods, namely, sinusoidal pulse-width-modulation, space vector modulation and hysteresis pulse-width-modulation have been used to generate pulses for the voltage source converter of the shunt active filter based on the reference currents generated using synchronous reference frame theory.  It has been demonstrated in the proposed paper that power factor correction, voltage regulation, better harmonic reduction and hence load compensation are obtained simultaneously by using two SAFs.</span><br />


Sign in / Sign up

Export Citation Format

Share Document