A comprehensive calibration method for non-orthogonal error and scale factor error of triaxial Helmholtz coil

2021 ◽  
Vol 92 (8) ◽  
pp. 085105
Author(s):  
Liangguang Yue ◽  
Defu Cheng ◽  
Yi Wang ◽  
Mingchao Wang ◽  
Jing Zhao
2012 ◽  
Vol 580 ◽  
pp. 146-150
Author(s):  
Ji Wei Zhang ◽  
Xiao Dong Xu ◽  
Bo Wang

In order to solve the problem that in the dual axle rotating modulation inertial navigation system the angle between the horizon roller of the system and horizontal plane can't be removed, this paper provides an on-line self calibration method based on inertial navigation system, and this method realized the on-line self calibration of the inertial navigation system by calculating bias and scale factor both of the gyroscope and accelerometer, solving the problem that in the dual axle rotating modulation inertial navigation system the angle between the horizon roller of the system and horizontal plane can't be removed, providing an calculable basis for the prediction of attitude angle and realizing on-line autonomous self-calibration.


2020 ◽  
Vol 127 ◽  
pp. 106149
Author(s):  
Fajie Duan ◽  
Ruijia Bao ◽  
Tingting Huang ◽  
Xiao Fu ◽  
Cong Zhang

Micromachines ◽  
2021 ◽  
Vol 13 (1) ◽  
pp. 62
Author(s):  
Xianshan Dong ◽  
Xinlong Huang ◽  
Guizhen Du ◽  
Qinwen Huang ◽  
Yixiong Huang ◽  
...  

For linear accelerometers, calibration with a precision centrifuge is a key technology, and the input acceleration imposed on the accelerometer should be accurately obtained in the calibration. However, there are often errors in the installation of sample that make the calibration inaccurate. To solve installation errors and obtain the input acceleration in the calibration of the accelerometer, a calibration method based on the rotation principle using a double turntable centrifuge is proposed in this work. The key operation is that the sub-turntable is rotated to make the input axis of the accelerometer perpendicular to the direction of the centripetal acceleration vector. Models of installation errors of angle and radius were built. Based on these models, the static radius and input acceleration can be obtained accurately, and the calibration of the scale factor, nonlinearity and asymmetry can be implemented. Using this method, measurements of the MEMS accelerometer with a range of ±30 g were carried out. The results show that the discrepancy of performance obtained from different installation positions was smaller than 100 ppm after calibrating the input acceleration. Moreover, the results using this method were consistent with those using the back-calculation method. These results demonstrate that the effectiveness of our proposed method was confirmed. This method can measure the static radius directly eliminating the installation errors of angle and radius, and it simplifies the accelerometer calibration procedure.


Sign in / Sign up

Export Citation Format

Share Document