The Tilted Hermann Grid Illusion: ‘Illusory Spots’ versus ‘Phantom Bands’

Perception ◽  
10.1068/p7192 ◽  
2012 ◽  
Vol 41 (2) ◽  
pp. 239-242 ◽  
Author(s):  
Kai Hamburger ◽  
Franziska Baier ◽  
Lothar Spillmann

The Hermann grid illusion became a cause célèbre, when it was reported that small figural changes from straight to curved bars abolish the dark illusory spots. We demonstrate that this is not an all-or-none effect; rather, the visual system tolerates some tilt/curviness. We transformed straight and curved Hermann grids to rhombic Motokawa grids by gradually tilting the horizontal bars. Initially we observed only dark illusory spots, then dark spots combined with phantom bands traversing the rhomb along the minor axis, and finally dark phantom bands only. This shows that two kinds of illusions can coexist in the same grid pattern.

2020 ◽  
Author(s):  
Bernt Skottun

The Hermann Grid is made up of a series of vertical and horizontal bars. The Hermann Grid Illusion consists in the brightness of the intersections appearing different from that of the sections between intersections in spite of the luminance being the same. In the case of a light grid on a dark background the intersections tend to appear darker than the parts between intersections. It is here pointed out, in two different ways, that the stimulus power is less for the parts of the grid located at intersections than for parts of the grid between intersections. This is all in the stimuli and does not depend on vision or the visual system. Were we to assume that a stronger stimulus gives a brighter appearance this would make the parts between intersections appear brighter than the parts of the grid at intersections. This would be consistent with the Hermann Grid Illusion.


2020 ◽  
Author(s):  
Samson Chengetanai ◽  
Adhil Bhagwandin ◽  
Mads F. Bertelsen ◽  
Therese Hård ◽  
Patrick R. Hof ◽  
...  

Author(s):  
Klaus-Ruediger Peters

Differential hysteresis processing is a new image processing technology that provides a tool for the display of image data information at any level of differential contrast resolution. This includes the maximum contrast resolution of the acquisition system which may be 1,000-times higher than that of the visual system (16 bit versus 6 bit). All microscopes acquire high precision contrasts at a level of <0.01-25% of the acquisition range in 16-bit - 8-bit data, but these contrasts are mostly invisible or only partially visible even in conventionally enhanced images. The processing principle of the differential hysteresis tool is based on hysteresis properties of intensity variations within an image.Differential hysteresis image processing moves a cursor of selected intensity range (hysteresis range) along lines through the image data reading each successive pixel intensity. The midpoint of the cursor provides the output data. If the intensity value of the following pixel falls outside of the actual cursor endpoint values, then the cursor follows the data either with its top or with its bottom, but if the pixels' intensity value falls within the cursor range, then the cursor maintains its intensity value.


Author(s):  
Steven M. Le Vine ◽  
David L. Wetzel

In situ FT-IR microspectroscopy has allowed spatially resolved interrogation of different parts of brain tissue. In previous work the spectrrscopic features of normal barin tissue were characterized. The white matter, gray matter and basal ganglia were mapped from appropriate peak area measurements from spectra obtained in a grid pattern. Bands prevalent in white matter were mostly associated with the lipid. These included 2927 and 1469 cm-1 due to CH2 as well as carbonyl at 1740 cm-1. Also 1235 and 1085 cm-1 due to phospholipid and galactocerebroside, respectively (Figs 1and2). Localized chemical changes in the white matter as a result of white matter diseases have been studied. This involved the documentation of localized chemical evidence of demyelination in shiverer mice in which the spectra of white matter lacked the marked contrast between it and gray matter exhibited in the white matter of normal mice (Fig. 3).The twitcher mouse, a model of Krabbe’s desease, was also studied. The purpose in this case was to look for a localized build-up of psychosine in the white matter caused by deficiencies in the enzyme responsible for its breakdown under normal conditions.


1996 ◽  
Vol 1 (3) ◽  
pp. 200-205 ◽  
Author(s):  
Carlo Umiltà ◽  
Francesca Simion ◽  
Eloisa Valenza

Four experiments were aimed at elucidating some aspects of the preference for facelike patterns in newborns. Experiment 1 showed a preference for a stimulus whose components were located in the correct arrangement for a human face. Experiment 2 showed a preference for stimuli that had optimal sensory properties for the newborn visual system. Experiment 3 showed that babies directed their attention to a facelike pattern even when it was presented simultaneously with a non-facelike stimulus with optimal sensory properties. Experiment 4 showed the preference for facelike patterns in the temporal hemifield but not in the nasal hemifield. It was concluded that newborns' preference for facelike patterns reflects the activity of a subcortical system which is sensitive to the structural properties of the stimulus.


Sign in / Sign up

Export Citation Format

Share Document