The Determination of Low Levels of Cyanide Ion Using a Silver Responsive Ion Selective Electrode

1971 ◽  
Vol 4 (7) ◽  
pp. 425-435 ◽  
Author(s):  
Bernard Fleet ◽  
Henning von Storp
1971 ◽  
Vol 54 (4) ◽  
pp. 760-763
Author(s):  
William L Hoover ◽  
James R Melton ◽  
Peggy A Howard

Abstract A method for determining low levels of iodide in feeds and plants is proposed. The samples are mixed with a 10% phosphate solution to maintain relatively constant ionic strength and pH and analyzed with a solid-state iodide electrode. Ashing is not required and there are no significant interferences by ions commonly found in feeds. The method is accurate in determining iodide content ranging from 10.0 ppm to high concentrations. Necessary conditions for storing and cleaning the electrodes are described. The proposed method is rapid and results compare favorably with AOAC method 7.091.


1981 ◽  
Vol 46 (2) ◽  
pp. 368-376 ◽  
Author(s):  
Josef Veselý

Titration of sulphates with lead perchlorate employing lead ion selective electrode indication was studied using additions of various organic solvents at different pH' and ionic strength values. As the optimum emerged systems with 60-70% 1,4-dioxane, pH' 5.3-5.6. After dehydration with sodium hydroxide, dioxane must be freed from the electrode surface-oxidizing impurities by their reduction with sodium metal and subsequent distillation. The method was applied to determination of sulphates in mountain spring waters. Units of ppm can be determined; the limit of determination, however, depends considerably on the content of dioxane, total salt content in the sample, and speed of the semi-automatic titration. Lead can be determined with EDTA in concentrations down to c(Pb2+) = 5 . 10-6 mol l-1.


Chemosensors ◽  
2021 ◽  
Vol 9 (7) ◽  
pp. 155
Author(s):  
Yan Su ◽  
Ting Liu ◽  
Caiqiao Song ◽  
Aiqiao Fan ◽  
Nan Zhu ◽  
...  

As an essential electrolyte for the human body, the potassium ion (K+) plays many physiological roles in living cells, so the rapid and accurate determination of serum K+ is of great significance. In this work, we developed a solid-contact ion-selective electrode (SC-ISE) using MoS2/Fe3O4 composites as the ion-to-electron transducer to determine serum K+. The potential response measurement of MoS2/Fe3O4/K+-ISE shows a Nernst response by a slope of 55.2 ± 0.1 mV/decade and a low detection limit of 6.3 × 10−6 M. The proposed electrode exhibits outstanding resistance to the interference of O2, CO2, light, and water layer formation. Remarkably, it also presents a high performance in potential reproducibility and long-term stability.


1983 ◽  
Vol 81 (1-2) ◽  
pp. 135-147 ◽  
Author(s):  
U. Thanei-Wyss ◽  
W. E. Morf ◽  
P. Lienemann ◽  
Z. Stefanac ◽  
I. Mostert ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document