Double-Pipe and Multitube Heat Exchangers with Plain and Longitudinal Finned Tubes

1997 ◽  
Vol 18 (2) ◽  
pp. 34-45 ◽  
Author(s):  
JERRY TABOREK
2021 ◽  
Vol 11 (13) ◽  
pp. 5954
Author(s):  
Muhammad Ishaq ◽  
Amjad Ali ◽  
Muhammad Amjad ◽  
Khalid Saifullah Syed ◽  
Zafar Iqbal

Heat transfer enhancement in heat exchangers results in thermal efficiency and energy saving. In double-pipe heat exchangers (DPHEs), extended or augmented fins in the annulus of the two concentric pipes, i.e., at the outer surface of the inner pipe, are used to extend the surface of contact for enhancing heat transfer. In this article, an innovative diamond-shaped design of extended fins is proposed for DPHEs. This type of fin is considered for the first time in the design of DPHEs. The triangular-shaped and rectangular-shaped fin designs of DPHE, available in the literature, can be recovered as special cases of the proposed design. An h-adaptive finite element method is employed for the solution of the governing equations. The results are computed for various performance measures against the emerging parameters. The results dictate that the optimal configurations of the diamond-shaped fins in the DPHE for an enhanced heat transfer are recommended as follows: If around 4–6, 8–12, or 16–32 fins are to be placed in the DPHE, then the height of the fins should be 20%, 80%, or 100%, respectively, of the annulus width. If frictional loss of heat is also to be considered, then for fin-heights of 20–80% and 100% of the annulus width, the placement of 4 and 8 diamond-shaped fins, respectively, is recommended for an enhanced heat transfer. These recommendations are for the radii ratio (i.e., the ratio of the inner pipe radius to that of the outer pipe) of 0.25. The recommendations are be modified if the radii ratio is altered.


2015 ◽  
Vol 68 (10) ◽  
pp. 1031-1049 ◽  
Author(s):  
Xi Chen ◽  
Fatemeh Tavakkoli ◽  
Kambiz Vafai

Author(s):  
N. F. Timerbaev ◽  
A. K. Ali ◽  
Omar Abdulhadi Mustafa Almohamed ◽  
A. R. Koryakin

In this article, a mathematical simulation of a double pipe heat exchanger is carried out, having the longitudinal rectangular fins with the dimension of (2*3*1000) mm, mounted on the outer surface of the inner tube of the heat exchanger. In this paper, the advantage of using of that type of fins and its effect on the effectiveness of the heat exchanger are studied with the help of the computer program. The carried out research allowsmaking the calculation to find the optimum design parameters of heat exchangers. The outer tube diameter is (34.1mm) while the inner tube diameter is (16.05mm). The tubes wall thickness is (1.5mm) and the model length was (1 m). The hot water is flowing through the inner tube in parallel with the cold water that passing the outer tube. The hot and cold water temperature at the inlet is (75°C & 30°C) respectively. The mass flow rate inside the central pipe is (0.1 kg/s) while the annular pipe carrying (0.3 kg/s). In the present work, the program ANSYS Workbench 15.0 was used to find out the results of heat transfer as well as the behavior of liquids inside the heat exchangers.


Author(s):  
Máté Petrik ◽  
Gábor Szepesi ◽  
Károly Jármai

2020 ◽  
Vol 142 (2) ◽  
Author(s):  
Samuel Gendebien ◽  
Alex Kleiman ◽  
Boris Leizeronok ◽  
Beni Cukurel

Abstract The present research deals with enhancing the thermal performance of turbulated heat exchangers through the application of sound pressure waves at acoustic resonance frequencies. Extending the findings of prior wind tunnel studies, where a standing wave greatly improved the forced convection in reattaching flows, this paper exploits such a phenomenon in a practical heat exchanger setting. The current experiments are conducted in representative turbulated plate and double-pipe heat exchanger geometries, mounted in a dedicated facility. After identifying the inherent acoustic resonance frequencies of the passageways, the impact of excitation is studied in various sound pressure levels, blockage ratios, as well as Strouhal and Reynolds numbers. The acoustic resonance excitation resulted in heat transfer enhancement of 20% and 10% in the plate and double-pipe designs, respectively, absence of additional pressure penalties. To the best knowledge of the authors, this is the first demonstration of acoustic forced convection enhancement in turbulated heat exchanger geometries. Such a technology can pave the way toward future designs that require low-pressure losses, minimal form factor, and/or process controllability.


Sign in / Sign up

Export Citation Format

Share Document