Pulmonary perfusion in acute pulmonary embolism: agreement of MRI and SPECT for lobar, segmental and subsegmental perfusion defects

2006 ◽  
Vol 47 (9) ◽  
pp. 933-940 ◽  
Author(s):  
A. Kluge ◽  
T. Gerriets ◽  
E. Stolz ◽  
T. Dill ◽  
K.-D. Mueller ◽  
...  
TH Open ◽  
2021 ◽  
Vol 05 (01) ◽  
pp. e66-e72
Author(s):  
Lisette F. van Dam ◽  
Lucia J. M. Kroft ◽  
Menno V. Huisman ◽  
Maarten K. Ninaber ◽  
Frederikus A. Klok

Abstract Background Computed tomography pulmonary angiography (CTPA) is the imaging modality of choice for the diagnosis of acute pulmonary embolism (PE). With computed tomography pulmonary perfusion (CTPP) additional information on lung perfusion can be assessed, but its value in PE risk stratification is unknown. We aimed to evaluate the correlation between CTPP-assessed perfusion defect score (PDS) and clinical presentation and its predictive value for adverse short-term outcome of acute PE. Patients and Methods This was an exploratory, observational study in 100 hemodynamically stable patients with CTPA-confirmed acute PE in whom CTPP was performed as part of routine clinical practice. We calculated the difference between the mean PDS in patients with versus without chest pain, dyspnea, and hemoptysis and 7-day adverse outcome. Multivariable logistic regression analysis and likelihood-ratio test were used to assess the added predictive value of PDS to CTPA parameters of right ventricle dysfunction and total thrombus load, for intensive care unit admission, reperfusion therapy and PE-related death. Results We found no correlation between PDS and clinical symptoms. PDS was correlated to reperfusion therapy (n = 4 with 16% higher PDS, 95% confidence interval [CI]: 3.5–28%) and PE-related mortality (n = 2 with 22% higher PDS, 95% CI: 4.9–38). Moreover, PDS had an added predictive value to CTPA assessment for PE-related mortality (from Chi-square 14 to 19, p = 0.02). Conclusion CTPP-assessed PDS was not correlated to clinical presentation of acute PE. However, PDS was correlated to reperfusion therapy and PE-related mortality and had an added predictive value to CTPA-reading for PE-related mortality; this added value needs to be demonstrated in larger studies.


2021 ◽  
Vol 199 ◽  
pp. 32-34
Author(s):  
Lisette F. van Dam ◽  
Lucia J.M. Kroft ◽  
Gudula J.A.M. Boon ◽  
Menno V. Huisman ◽  
Maarten K. Ninaber ◽  
...  

2000 ◽  
Vol 83 (03) ◽  
pp. 412-415 ◽  
Author(s):  
Franktien Turkstra ◽  
Marinus van Marwijk Kooy ◽  
Ad H. Oostdijk ◽  
Edwin J. van Beek ◽  
Harry Büller ◽  
...  

Summary BackgroundThe main purpose of ventilation scanning, as adjunct to perfusion lung scintigraphy, in acute pulmonary embolism is to allow for the classification of segmental perfusion defects as mismatched, which is generally accepted as proof for the presence of pulmonary embolism. We examined whether this function of the ventilation scan could be replaced by the chest X-ray.MethodsIn 389 consecutive patients with suspected pulmonary embolism and at least one segmental perfusion defect we classified the ventilation/perfusion (V/Q) scan and chest X-ray/perfusion (X/Q) scan as either mismatched or matched. Furthermore we analyzed whether this comparison was different in subgroups of patients with concomitant congestive heart failure or chronic obstructive pulmonary disease.Results Overall agreement between the X/Q and V/Q scan diagnostic category was found in 341 of 389 patients (88%; 95% CI 84-92%). The positive predictive value for obtaining a mismatched V/Q scan result in case of a mismatched X/Q scan result was 86% (95% CI 81-90%). If the X/Q scan yielded only matched defects the V/Q scan resulted in the same classification in 90% (95% CI 85-95%). Analysis of the small subgroup of patients with chronic obstructive pulmonary disease showed that a mismatched X/Q scan was confirmed by V/Q scanning in 21 of 34 cases (62%; 95% CI 45-78%).ConclusionThis study shows that in the great majority of patients with clinically suspected acute pulmonary embolism combination of chest X-ray with perfusion scintigraphy reliably replaced ventilation/perfusion scintigraphy in defining (mis)-matching of segmental perfusion defects. These results need confirmation before the chest X-ray can fully obviate the use of ventilation scintigraphy.


Medicine ◽  
2006 ◽  
Vol 85 (5) ◽  
pp. 253-262 ◽  
Author(s):  
Massimo Miniati ◽  
Simonetta Monti ◽  
Matteo Bottai ◽  
Elvio Scoscia ◽  
Carolina Bauleo ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document