Small-Signal Instability of PMSG Wind Farm Caused by the PLL Under the Condition of Near Strong Open-Loop Modal Resonance

2019 ◽  
Vol 47 (4-5) ◽  
pp. 301-315
Author(s):  
Wenjuan Du ◽  
Xubin Wang ◽  
Haifeng Wang
2019 ◽  

<p>Due to the intermittent and fluctuating nature of wind and other renewable energy sources, their integration into electricity systems requires large-scale and flexible storage systems to ensure uninterrupted power supply and to reduce the percentage of produced energy that is discarded or curtailed. Storage of large quantities of electricity in the form of dynamic energy of water masses by means of coupled reservoirs has been globally recognized as a mature, competitive and reliable technology; it is particularly useful in countries with mountainous terrain, such as Greece. Its application may increase the total energy output (and profit) of coupled wind-hydroelectric systems, without affecting the availability of water resources. Optimization of such renewable energy systems is a very complex, multi-dimensional, non-linear, multi modal, nonconvex and dynamic problem, as the reservoirs, besides hydroelectric power generation, serve many other objectives such as water supply, irrigation and flood mitigation. Moreover, their function should observe constraints such as environmental flow. In this paper we developed a combined simulation and optimization model to maximize the total benefits by integrating wind energy production into a pumped-storage multi-reservoir system, operating either in closed-loop or in open-loop mode. In this process, we have used genetic algorithms as the optimization tool. Our results show that when the operation of the reservoir system is coordinated with the wind farm, the hydroelectricity generation decreases drastically, but the total economical revenue of the system increases by 7.02% when operating in closed-loop and by 7.16% when operating in open-loop mode. We conclude that the hydro-wind coordination can achieve high wind energy penetration to the electricity grid, resulting in increase of the total benefits of the system. Moreover, the open-loop pumped-storage multi-reservoir system seems to have better performance, ability and flexibility to absorb the wind energy decreasing to a lesser extent the hydroelectricity generation, than the closed-loop.</p>


2020 ◽  
Author(s):  
Bart M. Doekemeijer ◽  
Stefan Kern ◽  
Sivateja Maturu ◽  
Stoyan Kanev ◽  
Bastian Salbert ◽  
...  

Abstract. The concept of wake steering in wind farms for power maximization has gained significant popularity over the last decade. Recent field trials described in the literature demonstrate the real potential of wake steering on commercial wind farms, but also show that wake steering does not yet consistently lead to an increase in energy production for all inflow conditions. Moreover, a recent survey among experts shows that validation of the concept remains the largest barrier for adoption currently. In response, this article presents the results of a field experiment investigating wake steering in three-turbine arrays at an onshore wind farm in Italy. This experiment was performed as part of the European CL-Windcon project. The measurements show increases in power production of up to 35 % for two-turbine interactions and up to 16 % for three-turbine interactions. However, losses in power production are seen for various regions of wind directions too. In addition to the gains achieved through wake steering at downstream turbines, more interesting to note is that a significant share in gains are from the upstream turbines, showing an increased power production of the yawed turbine itself compared to baseline operation for some wind directions. Furthermore, the surrogate model, while capturing the general trends of wake interaction, lacks the details necessary to accurately represent the measurements. This article supports the notion that further research is necessary, notably on the topics of wind farm modeling and experiment design, before wake steering will lead to consistent energy gains in commercial wind farms.


Energies ◽  
2019 ◽  
Vol 12 (11) ◽  
pp. 2035 ◽  
Author(s):  
Liang Chen ◽  
Heng Nian ◽  
Yunyang Xu

The sequence domain impedance modeling of wind turbines (WTs) has been widely used in the stability analysis between WTs and weak grids with high line impedance. An aggregated impedance model of the wind farm is required in the system-level analysis. However, directly aggregating WT small-signal impedance models will lead to an inaccurate aggregated impedance model due to the mismatch of reference frame definitions among different WT subsystems, which may lead to inaccuracy in the stability analysis. In this paper, we analyze the impacts of the reference frame mismatch between a local small-signal impedance model and a global one on the accuracy of aggregated impedance and the accuracy of impedance-based stability analysis. The results revealed that the impact is related to the power distribution of the studied network. It was found that that the influence of mismatch on stability analysis became subtle when subsystems were balanced loaded. Considering that balanced loading is a common configuration of the practical application, direct impedance aggregation by local small-signal models can be applied due to its acceptable accuracy.