“Abdominoplasty with “En block” removal of the skin island: a safe and fast approach”

Author(s):  
Mustafa Sutcu ◽  
Mustafa Keskin ◽  
Naci Karacaoglan
Keyword(s):  
2003 ◽  
Vol 112 (5) ◽  
pp. 1362-1367 ◽  
Author(s):  
Christian Rainer ◽  
Romed Meirer ◽  
Alexander Gardetto ◽  
Anton H. Schwabegger ◽  
Milomir M. Ninkovic

2021 ◽  
Vol 16 (1) ◽  
Author(s):  
Zhaobiao Luo ◽  
Jiangdong Ni ◽  
Guohua Lv ◽  
Jianwei Wei ◽  
Lihong Liu ◽  
...  

Abstract Background No large series have analysed distally based sural fasciocutaneous (DBSF) flaps in paediatric patients. The aims of this study were to assess the reliability and analyse the potential risk factors for these flaps and to describe complications in the donor site and the functional follow-up results. Methods Between June 2002 and November 2017, 88 DBSF flaps were used to reconstruct soft tissue defects in paediatric patients. Potential risk factors, reconstruction outcomes, and complications in the donor site of the flaps were analysed. Results Among the 88 flaps, partial necrosis developed in 8 flaps (9.1%). The partial necrosis rate was significantly higher in flaps with the top edge located in the 9th zone (26.1%), with a length-width ratio (LWR) ≥ 5:1 (28.6%), and with a dimension of the skin island ≥ 100 cm2 (22.7%). Partial necrosis did not occur in flaps with a dimension of the skin island < 80.0 cm2 or with a skin-island width < 7.0 cm. The reconstruction outcomes in most paediatric patients were evaluated as “excellent” or “good”. The incidence of obvious scarring was higher in the donor site. Conclusions Partial necrosis of DBSF flaps will significantly increase when the top edge of the flap is located in the 9th zone, when the LWR of the flap is ≥ 5:1, or when the dimension of the skin island is ≥ 100.0 cm2. Flaps with a skin-island width < 7.0 cm or with a dimension of the skin island < 80 cm2 are relatively safe and reliable.


2009 ◽  
Vol 75 (9) ◽  
pp. 1059-1067 ◽  
Author(s):  
Mi Wang ◽  
Fen Hu ◽  
Jonathan Li ◽  
Jun Pan
Keyword(s):  

2021 ◽  
pp. 147592172110419
Author(s):  
Zixian Zhou ◽  
Zhiwen Cui ◽  
Tribikram Kundu

Thin spherical shell structures are wildly used as pressure vessels in the industry because of their property of having equal in-plane normal stresses in all directions. Since very large pressure difference between the inside and outside of the wall exists, any formation of defects in the pressure vessel wall has a huge safety risk. Therefore, it is necessary to quickly locate the area where the defect maybe located in the early stage of defect formation and make repair on time. The conventional acoustic source localization techniques for spherical shells require either direction-dependent velocity profile knowledge or a large number of sensors to form an array. In this study, we propose a fast approach for acoustic source localization on thin isotropic and anisotropic spherical shells. A solution technique based on the time difference of arrival on a thin spherical shell without the prior knowledge of direction-dependent velocity profile is provided. With the help of “L”-shaped sensor clusters, only 6 sensors are required to quickly predict the acoustic source location for anisotropic spherical shells. For isotropic spherical shells, only 4 sensors are required. Simulation and experimental results show that this technique works well for both isotropic and anisotropic spherical shells.


Sign in / Sign up

Export Citation Format

Share Document