Uncertainty analysis for different virtual pump water flow meters

2019 ◽  
Vol 25 (3) ◽  
pp. 297-308 ◽  
Author(s):  
Gang Wang ◽  
Zufen Wang ◽  
Li Song
2013 ◽  
Vol 15 (3) ◽  
pp. 888-896 ◽  
Author(s):  
Songhao Wang ◽  
Ronald Garcia

The objective of this paper is to present the feasibility of a self-rechargeable digital water flow meter (SRDFM) system for water pipes using the latest data processing and wireless communication technologies while causing negligible water pressure drop (head loss). The system uses a Pelton turbine generator to power the electronic circuit, which processes and transmits the signals generated by several flow meters. ZigBee technology was used to process and send wireless signals. Signals from two water meters were acquired, processed, and transmitted with only one control/transmission unit during this study. The new system was assessed experimentally, reaching a maximum of 80 m of wireless transmittance distance at a minimum flow rate of 5 L/min for a 16-mm diameter pipe (self-charged).


Author(s):  
A. P. Vasilchenko ◽  
◽  
A. M. Korenovskiy ◽  

Purpose: analysis of existing ultrasonic methods and devices for metering water flow in irrigation and drainage systems. The problem of rational use of water resources exists in all areas, including agriculture. It cannot be resolved without considering the issue of water metering and water distribution. The main task of the water accounting system in irrigation and drainage systems is measuring the volume of water taken from the water intake and delovered to the irrigation network. For these purposes, flow meters – devices that measure the flow of water, are used. Ultrasonic (acoustic) flow meters are flow meters capable of solving complex problems in flow measurement. Currently, there are several measurement methods to determine the water flow rate at reclamation facilities: ultrasonic, radar, Doppler method, cross-correlation method and Transit-Time method. Based on these methods, a large number of modifications of devices for determining water flow rates have been created: level gauges, radar flow meters, Doppler flow meters, submersible cross-correlation flow meters, pulse-time flow meters. Conclusions. Flow meters based on level gauges and radar flow meters are impractical to use in commercial water metering units. They have high flow measurement errors, since level gauges measure only the level, and the speed is taken as a constant value, while radar flow meters measure the flow rate, but this is not the speed of the entire flow, but only of the surface layer. The flow rate measured by Doppler and cross-correlation meters depends on the amount of solids in the flow. But since the water in canals and closed pipelines on irrigation and drainage systems has a large number of solids, these flow meters have a high accuracy of flow measurement. Pulse time meters, as well as Doppler and cross-correlation meters, have high measurement accuracy, but do not depend on the amount of solids in the flow.


2015 ◽  
Vol 738-739 ◽  
pp. 849-853
Author(s):  
Xue Qin

Flow standard device not only is the reference and transferring of flow unit value, but also is widely used as experimental device .The research and application of it is an important link in the development of flow measurement and test technology. In view of the characteristics of industrial application fields, A set of "standard and combined" water flow device is researched and designed in the paper. The device will be static weight method and the standard meter method gives reasonable collocation from system scale and uncertainty synthesis, it can realize the verification and experimental studies of various velocity type flowmeter has the characteristics of high verification efficiency, low cost and high automation. More than flow meters have been calibrated on the device. It is confirmed by the operation status and the experimental data that every technology criterion has reached the design requirements, and it proved is reasonable to the design scheme about water flow standard device of master meter and static weight method.


Author(s):  
Thiago Amaral ◽  
Marcelo Silva ◽  
Fernanda Silva ◽  
luany braga ◽  
Diego Felipe ◽  
...  

2019 ◽  
Vol 191 ◽  
pp. 143-150 ◽  
Author(s):  
Zufen Wang ◽  
Esber Andiroglu ◽  
Gang Wang ◽  
Li Song

2020 ◽  
Vol 64 (9) ◽  
pp. 1615-1624
Author(s):  
R. A. Ribeiro ◽  
E. B. F. Dos Santos ◽  
P. D. C. Assunção ◽  
K. J. Daun ◽  
A. P. Gerlich

Author(s):  
A B Lawrence

Animal behaviour is increasingly seen as a useful tool in animal production. However, behavioural observations are time costly, and it is difficult to ensure precision and repeatability of measurement.An alternative to observation is to use electronics to automatically record behaviour and two such applications are illustrated:The first system developed at Edinburgh records drinker and chain-related activity, two common abnormal behaviours in pregnant sows. Water flow meters record drinker use. Chain behaviour is monitored by supplying each sow with a vertically hanging chain to which is attached piezo-electric ‘wire’. Electrical activity is generated from the flow meter or the piezo-electric wire as the sow manipulates the drinker or the chain, and is read by a micro-computer at 60 seconds intervals. The system estimates water use and circadian patterns of drinker and chain activity for 16 sows. Applications include recording the development of these two behaviours in response to variations in variables such as feeding regime.


2019 ◽  
Vol 8 (4) ◽  
pp. 6011-6017

Due to fluid properties, flow patterns, external factors (temperature, pressure, etc.) measurement shows a dynamical characteristic. Therefore, calibration is an indispensable process in order to ensure the standards of flow metering. Ultrasonic flow meters, which are ameliorated the readings over time, are promising devices to minimize the flow measurements error. In this paper, the calibration procedure of a specific ultrasonic water flow meter is discussed, and then a wireless system is proposed to carry out fine calibration. According to the results, piecewise linear least squares approach supplies the best performance at overall volumetric flow rates accompanying with wireless fine calibration system based on RF communication


Sign in / Sign up

Export Citation Format

Share Document