Role of Computed Tomography in Pre-Procedural Planning of Transcatheter Mitral Valve Replacement

2017 ◽  
Vol 2 (1) ◽  
pp. 23-29 ◽  
Author(s):  
Wong-Li Yu ◽  
Nima Omid-Fard ◽  
Chesnal Arepalli ◽  
Michael Shao ◽  
Shmuel L. Hart ◽  
...  
2021 ◽  
Author(s):  
Lina Ya’qoub ◽  
Marvin Eng

We will review transcatheter mitral valve replacement (TMVR) and discuss this evolving cutting edge procedure in terms of types (valve in valve, valve in ring and valve in mitral annular calcification MAC), clinical indications, pre-procedural planning and value of pre-procedural imaging including computed tomography role, technical challenges encountered in these procedures, potential complications for each type of TMVR, and potential strategies to mitigate and avoid such complications, We will review the currently available devices dedicated for mitral valve replacement, with a summary of their preliminary data and early outcome results. We will also discuss knowledge gaps and ideas for future research.


2021 ◽  
Vol 22 (Supplement_1) ◽  
Author(s):  
A Coisne ◽  
F Pontana ◽  
S Aghezzaf ◽  
S Mouton ◽  
H Ridon ◽  
...  

Abstract Funding Acknowledgements Type of funding sources: None. Background.  3-dimensional transoesophageal echocardiography (3D-TEE) is frequently used as an initial screening tool in the evaluation of patients who are candidates to Transcatheter Mitral Valve Replacement (TMVR). However, little is known about the imaging correlation with the gold-standard computed tomography (CT) imaging. We aimed at testing the quantitative differences between these two modalities and finding the best 3D-TEE parameters for TMVR screening. Methods. We included 57 patients referred to our Heart Valve Clinic for TMVR with prostheses specifically designed for the mitral valve. Mitral annulus (MA) analyses were performed using commercially available software in 3D-TEE and CT. Results. 3D-TEE was feasible in 52 patients (91%). Although 3D-TEE measurements were slightly lower than in CT, both measurements of projected MA area and perimeter showed excellent correlation with small differences between the two modalities (r = 0.88 and r = 0.92 respectively, p < 0.0001). Correlations were significant but lower for MA diameters (r = 0.68 to 0.72, p < 0.0001) and mitro-aortic angle (r = 0.53, p = 0.0001). ROC curve analyses showed that 3D-TEE had a good ability to predict TMVR screening success defined by constructors based on CT measurements with a range of 12.9 to 15cm² for MA area (AUC = 0.88-0.91, p < 0.0001), 128 to 139mm for MA perimeter (AUC = 0.85-0.91, p < 0.0001), 35 to 39mm for anteroposterior diameter (AUC = 0.79-0.84 p < 0.0001) and 37 to 42mm for posteromedial-anterolateral diameter (AUC = 0.81-0.89, p < 0.0001) (Figure 1). Conclusion. 3D-TEE measurements of MA dimensions display strong correlation with CT measurements in patients undergoing TMVR screening process. 3D-TEE should be proposed as a reasonable alternative to CT in this vulnerable population. Abstract Figure.


Author(s):  
Abdallah El Sabbagh ◽  
Mohammed Al-Hijji ◽  
Dee Dee Wang ◽  
Mackram Eleid ◽  
Marina Urena ◽  
...  

Background: Several studies have evaluated preprocedural imaging predictors of left ventricular outflow tract obstruction (LVOTO) after transcatheter mitral valve replacement. The patient cohorts in these studies were heterogeneous and included patients with transcatheter mitral valve replacement in failed bioprostheses, annuloplasty rings, and severe mitral annular calcification (MAC). The goal of this study was to evaluate predictors of LVOTO specific to patients undergoing valve-in-MAC. Methods: This study included patients with severe MAC who underwent valve-in-MAC and had optimal quality preprocedural multidetector row computed tomography scans eligible for retrospective analysis. Baseline demographic, echocardiographic, and procedural data on these patients were collected. multidetector row computed tomography parameters were analyzed for association with LVOTO, defined as increase in mean LVOT gradient by ≥10 mm Hg with accompanying hemodynamic instability. Results: Seventy-one patients with optimal preprocedural computed tomography scans were included in this study (mean age, 72.5±13.5 years), 9 of which developed LVOTO (all female). Baseline mean LVOT area, neo-LVOT area (145.3 versus 270.9 mm 2 ; P =0.006), indexed neo-LVOT area (90.1 versus 157.4; P =0.05), and virtual transcatheter heart valve to septum distance (3.1 versus 6.9 mm; P =0.002) were lower in the LVOTO group. Expected % LVOT area reduction was higher in the latter group (58.3 versus 42.7%; P =0.008). In the univariable analysis, the baseline mean LVOT area, neo-LVOT area, indexed neo-LVOT area, and valve to septum distance were all significantly associated with LVOTO. Conclusions: The systolic mean LVOT area, neo-LVOT area, indexed neo-LVOT, expected percentage LVOT area reduction, and the valve to septum distance were associated with LVOTO after valve-in-MAC.


2020 ◽  
Vol 4 (3) ◽  
pp. 1-6 ◽  
Author(s):  
Joris Ooms ◽  
Magali Minet ◽  
Joost Daemen ◽  
Nicolas Van Mieghem

Abstract Background Transcatheter mitral valve replacement (TMVR) may be a valuable treatment option for mitral annular calcification and severe mitral stenosis (MS) in patients at high operative risk. Pre-procedural virtual and printed simulations may aid in procedure planning, device sizing, and mitigate complications such as valve embolization or left ventricular outflow tract (LVOT) obstruction. Case summary We describe a case of TMVR in which multi-detector computed tomography (MDCT) derived, three-dimensional virtual planning and a 3D-printed model of the patients’ left heart provided enhanced understanding of an individual patient’s unique anatomy to determine feasibility, device sizing, and risk stratification. This resulted in deployment of an adequately sized valve. Post-TMVR LVOT obstruction was treated with LVOT balloon dilatation and percutaneous transluminal septal myocardial ablation. Discussion Advanced MDCT-derived planning techniques introduce consistent 3D modeling and printing to enhance understanding of intracardiac anatomical relationships and test device implantation. Still, static measurements do not feature haemodynamic factors, tissue, or device characteristics and do not predict device host interaction. Transcatheter mitral valve replacement is feasible in MS when adequately pre-procedurally planned. Multi-detector computed tomography-derived, 3D, virtual and printed models contribute to adequate planning in terms of determining patient eligibility, procedure feasibility, and device sizing. However, static 3D modeling cannot completely eliminate the risk of peri-procedural complications.


Author(s):  
Yin Ge ◽  
Sumit Gupta ◽  
Emilio Fentanes ◽  
Ayaz Aghayev ◽  
Michael Steigner ◽  
...  

2021 ◽  
Vol 8 ◽  
Author(s):  
Enrique Garcia-Sayan ◽  
Tiffany Chen ◽  
Omar K. Khalique

Transcatheter mitral valve interventions are an evolving and growing field in which multimodality cardiac imaging is essential for diagnosis, procedural planning, and intraprocedural guidance. Currently, transcatheter mitral valve-in-valve with a balloon-expandable valve is the only form of transcatheter mitral valve replacement (TMVR) approved by the FDA, but valve-in-ring and valve-in-mitral annular calcification interventions are increasingly being performed. Additionally, there are several devices under investigation for implantation in a native annulus. Paravalvular leak (PVL) is a known complication of surgical or transcatheter valve implantation, where regurgitant flow occurs between the prosthetic sewing ring and the native mitral annulus. We sought to describe the role and applications of multimodality cardiac imaging for TMVR, and PVL closure, including the use of Cardiovascular Computed Tomography Angiography and 3-Dimensional Transesophageal Echocardiography for diagnosis, prosthetic valve evaluation, pre-procedural planning, and intraprocedural guidance, as well as evolving technologies such as fusion imaging and 3D printing.


Sign in / Sign up

Export Citation Format

Share Document