Numerical analysis of the influence of splitter-plate erosion on an air arc in the quenching chamber of a low-voltage circuit breaker

2010 ◽  
Vol 43 (43) ◽  
pp. 434011 ◽  
Author(s):  
Fei Yang ◽  
Mingzhe Rong ◽  
Yi Wu ◽  
Anthony B Murphy ◽  
Jun Pei ◽  
...  
Electronics ◽  
2020 ◽  
Vol 9 (12) ◽  
pp. 2148
Author(s):  
Young-Maan Cho ◽  
Kun-A Lee

The low-voltage circuit breakers are widely used to protect loads in the distribution system. Interruption reliability of circuit breakers is important because they are a protective device close to the customer. In particular, the re-ignition phenomenon leads to over-current blocking failure due to the arc re-formed between electrodes despite the normal trip of the circuit breaker. In this paper, in order to improve the interruption performance against re-ignition, the dielectric recovery voltage measurement system of the circuit breaker is used and the experiment of changing the splitter plate is carried out. Two experiments are carried out by changing the splitter plate, especially changing the material of splitter plate and the number of lower plates of the splitter plate. In the case of changing the material of the splitter plate, the analysis is conducted according to the thermal conductance. In the case of changing the number of lower plates of the splitter plate, the number of plates and their spacing are variables. Analyzing the results of the dielectric recovery voltage experiment, in the initial period, copper plates have the best value that shows 102.1% improvement compared to normal and Al shows 59.8% improvement compared to normal. These increases are related to the thermal conductivity of the three electrode materials. In the case of changing the number of lower plates of the splitter plate, the 8-plates and 9-plates show 84.5% and 36.1% increases compared to normal, respectively, in the initial period. It can be seen that too many plates interfere with heat dissipation. Since this study studies performance improvement during the initial period, there is not much difference in the later period. This is consistent with the experimental results. In this study, an experimental basis is provided for the dielectric recovery strength from a low-voltage circuit breaker. It is expected that this will contribute to the research to improve the dielectric recovery capability of the circuit breaker.


2021 ◽  
Author(s):  
Sudipta Sen ◽  
Shahab Mehraeen ◽  
Keyue Smedley

2005 ◽  
Vol 7 (5) ◽  
pp. 3069-3072 ◽  
Author(s):  
Li Xingwen ◽  
Chen Degui ◽  
Wang Qian ◽  
Li Zhipeng

2015 ◽  
Vol 49 (2) ◽  
pp. 299-314
Author(s):  
Yingyi Liu ◽  
Degui Chen ◽  
Haiwen Yuan ◽  
Liang Ji ◽  
Qiusheng Wang ◽  
...  

Energies ◽  
2020 ◽  
Vol 13 (2) ◽  
pp. 338
Author(s):  
Leslie Tracy ◽  
Praveen Kumar Sekhar

In this study, a low voltage solid-state circuit breaker (SSCB) was implemented for a DC distribution system using commercially available components. The design process of the high-side static switch was enabled through a voltage bias. Detailed functional testing of the current sensor, high-side switch, thermal ratings, analog to digital conversion (ADC) techniques, and response times of the SSCB was evaluated. The designed SSCB was capable of low-end lighting protection applications and tested at 50 V. A 15 A continuous current rating was obtained, and the minimum response time of the SSCB was nearly 290 times faster than that of conventional AC protection methods. The SSCB was implemented to fill the gap where traditional AC protection schemes have failed. DC distribution systems are capable of extreme faults that can destroy sensitive power electronic equipment. However, continued research and development of the SSCB is helping to revolutionize the power industry and change the current power distribution methods to better utilize clean renewable energy systems.