Performance comparison of a dedicated total breast PET system with a clinical whole-body PET system: a simulation study

Author(s):  
Suranjana Samanta ◽  
Jianyong Jiang ◽  
Mahdjoub Hamdi ◽  
Alan Z Register ◽  
Stanislaw Majewski ◽  
...  
2020 ◽  
Vol 152 ◽  
pp. S917-S918
Author(s):  
J. Baran ◽  
J. Gajewski ◽  
M. Garbacz ◽  
M. Pawlik-Niedźwiecka ◽  
P. Moskal ◽  
...  

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Philippe Thuillier ◽  
David Bourhis ◽  
Jean Philippe Metges ◽  
Romain Le Pennec ◽  
Karim Amrane ◽  
...  

AbstractTo present the feasibility of a dynamic whole-body (DWB) 68Ga-DOTATOC-PET/CT acquisition in patients with well-differentiated neuroendocrine tumors (WD-NETs). Sixty-one patients who underwent a DWB 68Ga-DOTATOC-PET/CT for a histologically proven/highly suspected WD-NET were prospectively included. The acquisition consisted in single-bed dynamic acquisition centered on the heart, followed by the DWB and static acquisitions. For liver, spleen and tumor (1–5/patient), Ki values (in ml/min/100 ml) were calculated according to Patlak's analysis and tumor-to-liver (TLR-Ki) and tumor-to-spleen ratios (TSR-Ki) were recorded. Ki-based parameters were compared to static parameters (SUVmax/SUVmean, TLR/TSRmean, according to liver/spleen SUVmean), in the whole-cohort and according to the PET system (analog/digital). A correlation analysis between SUVmean/Ki was performed using linear and non-linear regressions. Ki-liver was not influenced by the PET system used, unlike SUVmax/SUVmean. The regression analysis showed a non-linear relation between Ki/SUVmean (R2 = 0.55,0.68 and 0.71 for liver, spleen and tumor uptake, respectively) and a linear relation between TLRmean/TLR-Ki (R2 = 0.75). These results were not affected by the PET system, on the contrary of the relation between TSRmean/TSR-Ki (R2 = 0.94 and 0.73 using linear and non-linear regressions in digital and analog systems, respectively). Our study is the first showing the feasibility of a DWB 68Ga-DOTATOC-PET/CT acquisition in WD-NETs.


1989 ◽  
Vol 31 (3) ◽  
pp. 135-138
Author(s):  
Maria K. Sato ◽  
Aldo J. Rodrigues Junior ◽  
Edwaldo E. Camargo

The present study describes a method for labeling Salmonella typhymurium with iodine-131 to evaluate both the morphological and the functional characteristics of the reticulo-endothelial system. A suspension containing 2 x 10(9) bacteria per ml was labeled with carrier-free Na131I without reductor, with a labeling yield of 46.5 ± 3% and 3.5 ± 1.3% of free Iodine-131. The biodistribution of the labeled bacteria in rats was studied with a large field-of-view scintillation camera equiped with a pinhole collimator. Whole body images were obtained 15 and 30 minutes after intravenous injection of the labeled microorganisms. Images showed accumulation of bacteria in the liver and both normal and transplanted spleens of the animals. Autoradiographs of liver and spleen demonstrated labeled bacteria within the cells of the reticulo-endothelial system. The method described is easy to perform, has a good labeling yield and allows the functional evaluation of the reticulo-monophagocytic system, including transplanted spleens.


Sign in / Sign up

Export Citation Format

Share Document