scholarly journals Sub-μs time resolution in wide-field time-correlated single photon counting microscopy obtained from the photon event phosphor decay

2015 ◽  
Vol 17 (2) ◽  
pp. 023032 ◽  
Author(s):  
Liisa M Hirvonen ◽  
Zdeněk Petrášek ◽  
Andrew Beeby ◽  
Klaus Suhling
Author(s):  
Maria Concetta Maccarone ◽  
Giovanni La Rosa ◽  
Osvaldo Catalano ◽  
Salvo Giarrusso ◽  
Alberto Segreto ◽  
...  

AbstractUVscope is an instrument, based on a multi-pixel photon detector, developed to support experimental activities for high-energy astrophysics and cosmic ray research. The instrument, working in single photon counting mode, is designed to directly measure light flux in the wavelengths range 300-650 nm. The instrument can be used in a wide field of applications where the knowledge of the nocturnal environmental luminosity is required. Currently, one UVscope instrument is allocated onto the external structure of the ASTRI-Horn Cherenkov telescope devoted to the gamma-ray astronomy at very high energies. Being co-aligned with the ASTRI-Horn camera axis, UVscope can measure the diffuse emission of the night sky background simultaneously with the ASTRI-Horn camera, without any interference with the main telescope data taking procedures. UVscope is properly calibrated and it is used as an independent reference instrument for test and diagnostic of the novel ASTRI-Horn telescope.


2013 ◽  
Vol 368 (1611) ◽  
pp. 20120035 ◽  
Author(s):  
X. Michalet ◽  
R. A. Colyer ◽  
G. Scalia ◽  
A. Ingargiola ◽  
R. Lin ◽  
...  

Two optical configurations are commonly used in single-molecule fluorescence microscopy: point-like excitation and detection to study freely diffusing molecules, and wide field illumination and detection to study surface immobilized or slowly diffusing molecules. Both approaches have common features, but also differ in significant aspects. In particular, they use different detectors, which share some requirements but also have major technical differences. Currently, two types of detectors best fulfil the needs of each approach: single-photon-counting avalanche diodes (SPADs) for point-like detection, and electron-multiplying charge-coupled devices (EMCCDs) for wide field detection. However, there is room for improvements in both cases. The first configuration suffers from low throughput owing to the analysis of data from a single location. The second, on the other hand, is limited to relatively low frame rates and loses the benefit of single-photon-counting approaches. During the past few years, new developments in point-like and wide field detectors have started addressing some of these issues. Here, we describe our recent progresses towards increasing the throughput of single-molecule fluorescence spectroscopy in solution using parallel arrays of SPADs. We also discuss our development of large area photon-counting cameras achieving subnanosecond resolution for fluorescence lifetime imaging applications at the single-molecule level.


Four methods of applying mode-locked lasers to time-resolved fluorescence measurements in the subnanosecond region are compared. When time resolution below 100 ps is not required, the most precise and sensitive method is single-photon counting, and the application of this method to studies of time-resolved fluorescence of tryptophan in simple peptides is described. The dependence of lifetimes on pH and temperature are interpreted in terms of quenching by intramolecular proton and electron transfers.


2021 ◽  
Author(s):  
Matteo Battisti ◽  
Enrico Arnone ◽  
Mario Bertaina ◽  
Marco Casolino ◽  
Laura Marcelli ◽  
...  

<p>Elves are the most common type of transient luminous events, with estimates of their global occurrence rate ranging from a few to a few tens per minute. Here, we present the first derivation of the global occurrence rate of elves from Mini-EUSO observations. Mini-EUSO is a wide field of view, space-based telescope operating from a nadir-facing UV-transparent window in the Russian Zvezda module on the International Space Station. It observes the Earth’s atmosphere in the UV band with a spatial resolution of about 6.3 km and a temporal resolution of 2.5 μs. Its optical system made of two 25 cm diameter Fresnel lenses focuses the light into a square array of 48x48 pixels, each pixel being capable of single photon counting. Originally designed to detect the faint fluorescence light produced by extensive air showers induced by extreme energy cosmic rays, it was shown to be capable of detecting a wide range of atmospheric phenomena, including elves. Elves are dynamically traced by Mini-EUSO in their horizontally expanding, fast donut-shaped light emissions and can therefore be unequivocally identified. Mini-EUSO can usually detect elves whose center is just outside the field of view, following the expansion of the ring for hundreds of microseconds. Combining the number of detected elves with consideration of the time and geometries, it is possible to derive a first estimate of their global occurrence rate with Mini-EUSO, and to compare it to the literature. </p>


2012 ◽  
Vol 83 (12) ◽  
pp. 123103 ◽  
Author(s):  
Julia Toussaint ◽  
Roman Grüner ◽  
Marco Schubert ◽  
Torsten May ◽  
Hans-Georg Meyer ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document