scholarly journals Single Particle Detection System for Strong-Field QED Experiments

Author(s):  
Felipe Cezar Salgado ◽  
Niall Cavanagh ◽  
Matteo Tamburini ◽  
Doug Wesley Storey ◽  
Roland Beyer ◽  
...  

Abstract Measuring signatures of strong-field quantum electrodynamics (SF-QED) processes in an intense laser field is an experimental challenge: it requires detectors to be highly sensitive to single electrons and positrons in the presence of the typically very strong x-ray and γ-photon background levels. In this paper, we describe a particle detector capable of diagnosing single leptons from SF-QED interactions and discuss the background level simulations for the upcoming Experiment-320 at FACET-II (SLAC National Accelerator Laboratory). The single particle detection system described here combines pixelated scintillation LYSO screens and a Cherenkov calorimeter. We detail the performance of the system using simulations and a calibration of the Cherenkov detector at the ELBE accelerator. Single 3 GeV leptons are expected to produce approximately 537 detectable photons in a single calorimeter channel. This signal is compared to Monte-Carlo simulations of the experiment. A signal-to-noise ratio of 18 in a single Cherenkov calorimeter detector is expected and a spectral resolution of 2% is achieved using the pixelated LYSO screens.

Author(s):  
Norbert Jahr ◽  
Nicole Hädrich ◽  
Mamuna Anwar ◽  
Andrea Csaki ◽  
Ondra Stranik ◽  
...  

2009 ◽  
Vol 2009 ◽  
pp. 1-14
Author(s):  
Xihong Wu ◽  
J. A. Merten ◽  
N. Omenetto ◽  
B. W. Smith ◽  
J. D. Winefordner

This paper describes the experimental realization and characterization of a versatile single particle detection apparatus. The system utilizes a novel particle beam inlet that can serve as either an on-line particle concentrator (i.e., all diameters confined in a narrow beam) or as a segregator (i.e., selected diameters confined in a narrow beam) and can be operated in a high-speed mode as well as in a low-speed mode, thus allowing different interaction times between the particles and the laser beam. An aerodynamic sizing technique has been incorporated into the system to provide rapid, real-time, and high-resolution sizing. Parameters such as transmission efficiency and size-segregation efficiency have been measured. The performance of the instrument has been demonstrated by on-line detection of spectrally resolved and time resolved fluorescence detection from airborne dye-doped particles and aerosolized endogenous fluorophores found in biological agents.


Proceedings ◽  
2020 ◽  
Vol 56 (1) ◽  
pp. 16
Author(s):  
Andreas Tortschanoff ◽  
Marcus Baumgart ◽  
Jaka Pribošek

Evanescent field particle scattering is a promising method for single particle detection. In this study, we performed a detailed numerical analysis to show the possibilities and limitations of analytical models for predicting the capabilities of this sensing mechanism.


Lab on a Chip ◽  
2019 ◽  
Vol 19 (14) ◽  
pp. 2394-2403 ◽  
Author(s):  
Irene Fernandez-Cuesta ◽  
Melanie Maputol West ◽  
Enrica Montinaro ◽  
Adam Schwartzberg ◽  
Stefano Cabrini

A gold bowtie nanoantenna integrated with a 30 nm × 30 nm nanochannel for single particle detection and counting in real time.


Sign in / Sign up

Export Citation Format

Share Document