scholarly journals Platinum dissolution and tissue response following long-term electrical stimulation at high charge densities

2021 ◽  
Vol 18 (3) ◽  
pp. 036021
Author(s):  
Robert K Shepherd ◽  
Paul M Carter ◽  
Ashley N Dalrymple ◽  
Ya Lang Enke ◽  
Andrew K Wise ◽  
...  
2020 ◽  
Vol 17 (5) ◽  
pp. 056009
Author(s):  
Robert K Shepherd ◽  
Paul M Carter ◽  
Ya Lang Enke ◽  
Alex Thompson ◽  
Brianna Flynn ◽  
...  

2021 ◽  
pp. 1-10
Author(s):  
Michihiro Osumi ◽  
Daisuke Shimizu ◽  
Yuki Nishi ◽  
Shu Morioka

Background: Patients with brachial plexus avulsion (BPA) usually experience phantom sensations and phantom limb pain (PLP) in the deafferented limb. It has been suggested that evoking the sensation of touch in the deafferented limb by stimulating referred sensation areas (RSAs) on the cheek or shoulder might alleviate PLP. However, feasible rehabilitation techniques using this approach have not been reported. Objective: The present study sought to examine the analgesic effects of simple electrical stimulation of RSAs in BPA patients with PLP. Methods: Study 1: Electrical stimulation of RSAs for 60 minutes was conducted for six BPA patients suffering from PLP to examine short-term analgesic effects. Study 2: A single case design experiment was conducted with two BPA patients to investigate whether electrical stimulation of RSAs was more effective for alleviating PLP than control electrical stimulation (electrical stimulation of sites on side opposite to the RSAs), and to elucidate the long-term effects of electrical stimulation of RSAs. Results: Study 1: Electrical stimulation of RSAs evoked phantom touch sensations in the deafferented limb, and significantly alleviated PLP (p <  0.05). Study 2: PLP was alleviated more after electrical stimulation on RSAs compared with control electrical stimulation (p <  0.05). However, the analgesic effects of electrical stimulation on RSAs were observed only in the short term, not in the long term (p >  0.05). Conclusions: Electrical stimulation of RSAs not only evoked phantom touch sensation but also alleviated PLP in the short term. The results indicate that electrical stimulation of RSAs may provide a useful practical rehabilitation technique for PLP. Future studies will be required to clarify the mechanisms underlying immediate PLP alleviation via electrical stimulation of RSAs.


2010 ◽  
Vol 43 (1) ◽  
pp. 65-75 ◽  
Author(s):  
Christopher M. Adams ◽  
Manish Suneja ◽  
Shauna Dudley-Javoroski ◽  
Richard K. Shields

Neurosurgery ◽  
2011 ◽  
Vol 69 (4) ◽  
pp. 921-929 ◽  
Author(s):  
Richard W Hutchinson ◽  
Vince Mendenhall ◽  
Randolph M Abutin ◽  
Tim Muench ◽  
James Hart

Abstract BACKGROUND: Watertight repair of the dura is imperative after neurosurgical procedures involving the brain or spinal cord because inadequately treated leakage of cerebrospinal fluid (CSF) from punctured dura can have serious consequences such as meningitis, arachnoiditis, or epidural abscess. OBJECTIVE: To assess the efficacy of Evicel Fibrin Sealant (Human) to prevent CSF leakage using a 2.0-cm durotomy mongrel dog repair model and to compare the tissue response with Tisseel (a fibrin sealant) and Duraseal (a synthetic polyethylene glycol [PEG] hydrogel sealant). METHODS: The canine durotomy repair model was used. This well-characterized model assesses the ability of sealants to achieve intraoperative watertight seals of the dura mater, as well as long-term safety and efficacy. This study included 27 mongrel dogs and had a 28-day duration. RESULTS: The 3 sealants were 100% effective in preventing CSF leakage intraoperatively at 15 mm Hg. The 2 fibrin sealants were 100% effective in postoperative sealing; the PEG hydrogel was not. Microscopically, the tissue changes induced by Evicel at the durotomy site were similar in nature except for foamy macrophages seen only with the PEG hydrogel. The extent and severity of adhesions at 28 days were less with the fibrin sealants than with the PEG hydrogel. CONCLUSION: Evicel, a fibrin sealant, was safe and effective in achieving and maintaining a watertight seal of the dura. The performance of the fibrin sealants was similar to that of the synthetic PEG hydrogel sealant with the exception of a Duraseal seal, which leaked.