scholarly journals Multicomponent force transducer calibration procedure using tilted plates

2018 ◽  
Vol 1065 ◽  
pp. 042015
Author(s):  
Stefano Palumbo ◽  
Andrea Prato ◽  
Fabrizio Mazzoleni ◽  
Alessandro Germak
IEEE Access ◽  
2019 ◽  
Vol 7 ◽  
pp. 48998-49003 ◽  
Author(s):  
Yelong Zheng ◽  
Meirong Zhao ◽  
Jile Jiang ◽  
Le Song

2014 ◽  
Vol 945-949 ◽  
pp. 1973-1977
Author(s):  
Yan Zhi Zhao ◽  
Gui Tao Li ◽  
Zhi Niu ◽  
Da Cheng Weng

The actual use conditions of force transducer is differences between the factory verification conditions, so based on the structure and working principles, this article is aimed at accurate calibration and proper use of force transducer. Through the CAE simulations and calibration experiments in actual working conditions which are the installation pre-tightening force, structure of fittings and pedestal’s hardness, analyses the output signals of force transducer. Force standard machine was carried out on the calibration experiment to verify the correctness of the numerical simulation. And then the outcomes obtained by numerical simulations and the calibration experiments, it studies the differences of every output performance index of force transducers in different working conditions above-mentioned.


1983 ◽  
Vol 48 (3) ◽  
pp. 722-734
Author(s):  
Martin Koval

The flame ionisation detector response to C6-C11 aliphatic hydrocarbon solutions in carbon disulphide in the concentration range between 1.3-9.5 mg ml-1 retained lineary despite the excess of solvent entering the detector simultaneously with the analyte. Pure carbon disulphide exhibited a small positive detector response which did not interfere in calibration procedure and which, under certain GC conditions, inverted to negative values. This response was not proportional to the injected volume and was strongly influenced by the column temperature and/or bleed. On the basis of these findings, a method compatible with the widely used charcoal tube carbon disulphide desorption procedure was developed and evaluated. It consists of static desorption of the sum of aliphatic alkanes and cycloalkanes from the activated charcoal after which an internal standard is added to the supernatant eluate. The resulting carbon disulphide solution is analysed on a highly polar stationary phase 1,2,3-tris(2-cyanoethoxy)propane where the solvent and the analyte coelute in a single peak, the height of which is practically proportional to the sum of alkanes and cycloalkanes present. This also makes determinations of other substances present in the sample more simple. The field test of the proposed method yielded values comparable in precision and accuracy with a control infrared spectrophotometric method.


Energies ◽  
2021 ◽  
Vol 14 (8) ◽  
pp. 2123
Author(s):  
Makuachukwu F. Mbaegbu ◽  
Puspa L. Adhikari ◽  
Ipsita Gupta ◽  
Mathew Rowe

Determining gas compositions from live well fluids on a drilling rig is critical for real time formation evaluation. Development and utilization of a reliable mass spectrometric method to accurately characterize these live well fluids are always challenging due to lack of a robust and effectively selective instrument and procedure. The methods currently utilized need better calibration for the characterization of light hydrocarbons (C1–C6) at lower concentrations. The primary goal of this research is to develop and optimize a powerful and reliable analytical method to characterize live well fluid using a quadruple mass spectrometer (MS). The mass spectrometers currently being used in the field have issues with detection, spectra deconvolution, and quantification of analytes at lower concentrations (10–500 ppm), particularly for the lighter (<30 m/z) hydrocarbons. The objectives of the present study are thus to identify the detection issues, develop and optimize a better method, calibrate and QA/QC the MS, and validate the MS method in lab settings. In this study, we used two mass spectrometers to develop a selective and precise method to quantitatively analyze low level lighter analytes (C1–C6 hydrocarbons) with masses <75 m/z at concentrations 10–500 ppm. Our results suggest that proper mass selection like using base peaks with m/z 15, 26, 41, 43, 73, and 87, respectively, for methane, ethane, propane, butane, pentane, and hexane can help detect and accurately quantify hydrocarbons from gas streams. This optimized method in quadrupole mass spectrometer (QMS) will be invaluable for early characterization of the fluid components from a live hydrocarbon well in the field in real time.


Author(s):  
Raul E. Avelar ◽  
Karen Dixon ◽  
Boniphace Kutela ◽  
Sam Klump ◽  
Beth Wemple ◽  
...  

The calibration of safety performance functions (SPFs) is a mechanism included in the Highway Safety Manual (HSM) to adjust SPFs in the HSM for use in intended jurisdictions. Critically, the quality of the calibration procedure must be assessed before using the calibrated SPFs. Multiple resources to aid practitioners in calibrating SPFs have been developed in the years following the publication of the HSM 1st edition. Similarly, the literature suggests multiple ways to assess the goodness-of-fit (GOF) of a calibrated SPF to a data set from a given jurisdiction. This paper uses the calibration results of multiple intersection SPFs to a large Mississippi safety database to examine the relations between multiple GOF metrics. The goal is to develop a sensible single index that leverages the joint information from multiple GOF metrics to assess overall quality of calibration. A factor analysis applied to the calibration results revealed three underlying factors explaining 76% of the variability in the data. From these results, the authors developed an index and performed a sensitivity analysis. The key metrics were found to be, in descending order: the deviation of the cumulative residual (CURE) plot from the 95% confidence area, the mean absolute deviation, the modified R-squared, and the value of the calibration factor. This paper also presents comparisons between the index and alternative scoring strategies, as well as an effort to verify the results using synthetic data. The developed index is recommended to comprehensively assess the quality of the calibrated intersection SPFs.