scholarly journals Influencing factors of water recycle device in cooling tower of thermal power plant based on corona discharge principle

2019 ◽  
Vol 1303 ◽  
pp. 012112
Author(s):  
Mingkun Zhang ◽  
Yinyi Wang ◽  
Jieyu Liu
2012 ◽  
Vol 16 (1) ◽  
pp. 263-270
Author(s):  
Vladimir Mijakovski ◽  
Vangelce Mitrevski ◽  
Nikola Mijakovski

Thermal power plant (TPP) - Bitola is the largest electricity producer in the Republic of Macedonia with installed capacity of 691 MW. It is a lignite fired power plant, in operation since 1982. Most of the installed equipment is of Russian origin. Power plant's cold end comprised of a condenser, pump station and cooling tower is depicted in the article. Possible way to raise the efficiency of the cold end by changing the operating characteristics of the pumps is presented in the article. Diagramic and tabular presentation of the working characteristics of the pumps (two pumps working in paralel for one block) with the pipeline, as well as engaged power for their operation are also presented in this article.


2014 ◽  
Vol 960-961 ◽  
pp. 1477-1482
Author(s):  
Dong Xiao Niu ◽  
Peng Wang ◽  
Qiong Wang ◽  
Fu Yu Hua ◽  
Feng Wang ◽  
...  

This paper sets the thermal power plant security management system as the research object. First of all, with the application of the Interpretative Structural Modeling (ISM), we establish a multi-level hierarchical structure model on analysis of the influencing factors of thermal power plant security management. Furthermore, based on the structure model, we use the Analytic Hierarchy Process (AHP) to determine weights of all the influencing factors, in order to identify the main factors. Finally, according to the identified main factors, we provide several suggestions for security management of thermal power plant.


The main aim of this work is to check the bio fouling in cooling tower and its effect on power generation. The way to reduce bio fouling is necessary issue within the thermal power station, as it results in reduction of the heat transfer rate and ultimately reduction in the power generation rate of plant. So as to attenuate the energy consumption in process plant equipped with device network. In various branches of chemical industries fouling builds up on heat transfer surfaces is a heat transfer equipment burning extra fuel to compensate for a reduced heat recovery accepting reduction of plant output due to periodic equipment cleaning and recovering the cost of cleaning interventions. Microbiological fouling can cause energy losses and loss of tower efficiency. The pilot plant is very useful in the thermal power plant to test the cooling water and then it is used in the thermal power plant to reduce the losses due to the bio fouling. In large power plant they having pilot plant with PLC system and microprocessor with highly accurate sensors. It will give very accurate and direct digital readings on screen


2017 ◽  
Vol 206 ◽  
pp. 1169-1183 ◽  
Author(s):  
Xiaoxiao Li ◽  
Hal Gurgenci ◽  
Zhiqiang Guan ◽  
Xurong Wang ◽  
Sam Duniam