scholarly journals Efficiency of electron beam extraction to the atmosphere in an accelerator based on ion-electron emission

2021 ◽  
Vol 2064 (1) ◽  
pp. 012116
Author(s):  
S Yu Doroshkevich ◽  
M S Vorobyov ◽  
M S Torba ◽  
N N Koval ◽  
S A Sulakshin ◽  
...  

Abstract The use of a modern element base makes it possible to create power supplies with a transition from a direct mode of generation of an auxiliary discharge to a pulse-periodic mode with a pulse repetition rate at the level of several tens of kHz. This allows for a more flexible adjustment of the discharge parameters, keeping the average value of its current, but changing its amplitude with a corresponding change in the pulse duty cycle. In this work, using an electron accelerator based on ion-electron emission, generating a wide-aperture electron beam, we research the effect of auxiliary discharge generation mode (direct and pulse-periodic) on the efficiency of electron beam extraction into the ambient atmosphere. It is shown that, in a direct mode of electron beam generation at an accelerating voltage of 150 kV, the beam extraction coefficient does not exceed 0.25. The possibility of increasing the extraction coefficient to K = 0.55 at the same accelerating voltage of 150 kV was demonstrated without making changes to the design of the accelerator, but switching to a pulsed-periodic mode of emission plasma generation.

2011 ◽  
Vol 39 (11) ◽  
pp. 2554-2555 ◽  
Author(s):  
Mahdi Yousefi ◽  
Vahid Damideh ◽  
Hamid Ghomi

Author(s):  
A.S. Chepusov ◽  
◽  
A.A. Komarskiy ◽  
S.R. Korzhenevskiy ◽  
O.D. Krasniy ◽  
...  

The article considers field emission cathodes from industrial graphites MG, MPG-7, and GMZ operated in the pulse-periodic mode with the pulse repetitionrate of 1 to 30 Hz. The operation of field emitters in the pulsed mode differs from operation at a constant voltage. Under stabilization of the high potential level, the amplitude of the pulses of the emission current decreases that leads to increasing the operating voltage in the pulsed mode. During operation of the graphite cathode (when the pulse current is recorded), the operating voltage at the anode stabilizes and oscillates within 5%. Operation in the direct current mode under similar conditions is accompanied by a change in the voltage value by more than 10 %.


AIP Advances ◽  
2019 ◽  
Vol 9 (1) ◽  
pp. 015122
Author(s):  
Jun Chen ◽  
Shixiu Chen ◽  
Jixiong Xiao ◽  
Shen Gao ◽  
Huafeng Cai ◽  
...  

Author(s):  
J. H. Lee ◽  
S. H. Lee ◽  
W. S. Kim ◽  
H. J. Lee ◽  
J. N. Heo ◽  
...  

Sign in / Sign up